A Pattern-Based OCT Metric for Glaucoma Detection
Translational Vision Science & Technology · 13.12.2024 · 13 (12) · 21
DOI: 10.1167/tvst.13.12.21 ↗Kurz gefasst
Fachartikel in der Zeitschrift Translational Vision Science & Technology, erschienen am 13.12.2024. Verfasst von Donald C Hood und 10 weiteren Autor:innen. Beteiligte Einrichtung: Bernard and Shirlee Brown Glaucoma Research Laboratory, Department of Ophthalmology, Edward S. Harkness Eye Institute, Columbia University Irving Med…. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Glaucoma, Nerve Fibers. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NEI NIH HHS.
Abstract (Originalsprache)
Purpose
To develop and test a novel optical coherence tomography (OCT) metric for the detection of glaucoma based on a logistic regression model (LRM) and known patterns of glaucomatous damage.
Methods
The six variables of the LRM were based on characteristic patterns of damage seen on the OCT thickness maps of the ganglion cell layer plus inner plexiform layer (GCL+) and retinal nerve fiber layer (RNFL). Two cohorts were used to develop the LRM. The healthy cohort consisted of 400 individuals randomly selected from a real-world reference database (RW-RDB) of OCT widefield scans from 4932 eyes/individuals obtained from 10 optometry practices. The glaucoma cohort consisted of 207 individuals from the same 10 practices but with OCT reports with evidence of optic neuropathy consistent with glaucoma (ON-G). Specificity was assessed with 396 eyes/individuals from a commercial RDB. Sensitivity was assessed with individuals with ON-G from different optometry practices.
Results
For the new LRM metric, the partial area under the reciever operating characteristic curve (AUROC) for specificity >90% was 0.92, and the sensitivity at 95% specificity was 88.8%. These values were significantly greater than those of a previously reported LRM metric (0.82 and 78.1%, respectively) and two common OCT thickness metrics: global circumpapillary RNFL (0.77 and 57.5%, respectively), and global GCL+IPL (0.72 and 47.6%, respectively).
Conclusions
The new metric outperformed other OCT metrics for detecting glaucomatous damage. Translational Relevance: The new metric has the potential to improve the accuracy of referrals from primary care to specialist care via risk scores and calculators, as well as glaucoma definitions for clinical trials. The individual variables of this model may also aid clinical diagnosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Bernard and Shirlee Brown Glaucoma Research Laboratory, Department of Ophthalmology, Edward S. Harkness Eye Institute, Columbia University Irving Medical Center, New York, NY, USA.
- Department of Psychology, Columbia University, New York, NY, USA.
- University of Pittsburgh Medical Center, Pittsburgh, PA, USA.
- Topcon Healthcare Inc., Oakland, NJ, USA.
- Illinois College of Optometry, Chicago, IL, USA.
Förderung
- NEI NIH HHS
Zitieren
APA
Hood, D. C., La Bruna, S., Durbin, M., Lee, C., Guzman, A., Gebhardt, T., Wang, Y., Stowman, A. L., De Moraes, C. G., Chaglasian, M., & Tsamis, E. (2024). A Pattern-Based OCT Metric for Glaucoma Detection. Translational Vision Science & Technology, 13(12), 21. https://doi.org/10.1167/tvst.13.12.21
Vancouver
Hood DC, La Bruna S, Durbin M, Lee C, Guzman A, Gebhardt T, et al. A Pattern-Based OCT Metric for Glaucoma Detection. Translational Vision Science & Technology. 2024;13(12):21. doi:10.1167/tvst.13.12.21
BibTeX
@article{Hood2024,
author = {Hood, Donald C and La Bruna, Sol and Durbin, Mary and Lee, Chris and Guzman, Anya and Gebhardt, Tayna and Wang, Yujia and Stowman, Arin L and De Moraes, Carlos Gustavo and Chaglasian, Michael and Tsamis, Emmanouil},
title = {A Pattern-Based OCT Metric for Glaucoma Detection},
journal = {Translational Vision Science & Technology},
year = {2024},
volume = {13},
number = {12},
pages = {21},
doi = {10.1167/tvst.13.12.21}
}
EUVIMED