Normative Variability in Retinal Nerve Fiber Layer Thickness: Does It Matter Where the Peaks Are?
Translational Vision Science & Technology · 2025
DOI: 10.1167/tvst.14.5.13 ↗Kurz gefasst
Fachartikel in der Zeitschrift Translational Vision Science & Technology, 2025. Verfasst von Sowjanya Gowrisankaran und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Casey Eye Institute, Oregon Health & Science University, Portland, OR, USA. Hauptthemen laut MEDLINE: Nerve Fibers, Retinal Ganglion Cells, Optic Disk, Glaucoma. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NEI NIH HHS.
Abstract (Originalsprache)
Purpose
Retinal nerve fiber layer thickness (RNFLT), a glaucoma biomarker, has a wide normative range affecting its sensitivity and specificity for abnormality detection. The interindividual RNFLT peak location variability contribution to this wide normative range has not been directly evaluated. The purpose of this study is to assess the effect of RNFLT peak normalization (PN) on normative variability.
Methods
Circumpapillary RNFLT profiles at 1.7 mm radius from the optic nerve head (ONH) were re-sampled from optical coherence tomography (OCT) volumes (Cirrus HD-OCT, 200 × 200) obtained from one eye of 83 healthy individuals. Fovea-ONH axis (FOA) was calculated from corresponding scanning laser ophthalmoscope images. Supratemporal (ST) and infratemporal (IT) RNFLT peaks of each profile were aligned to respective average peak locations. Normative ranges were calculated by averaging individual profiles before and after PN (with and without FOA to horizontal image axis (HA) alignment).
Results
RNFLT-PN resulted in an overall decrease in coefficient of variation (CoV) of the normative range by 4.2% (P = 0.02). CoV was reduced by more than 10% in clock-hours 10 (11.9%), 8 (10.6%), 6 (10.4%) after PN, and 7 (16.3%), 10 (11.4%), and 12 (10.4%) after PN with FOA-HA alignment. RNFLT-PN corrected for abnormality categorization because of peak misalignment in RNFLT profiles of healthy and glaucoma suspect subjects.
Conclusions
RNFLT-PN reduces normative variability, especially in the ST and IT regions. Translational Relevance: RNFLT-PN reduces normative variability and improves sectoral abnormality categorization, potentially leading to better sensitivity and specificity of RNFLT measure in glaucoma detection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Ophthalmology, Casey Eye Institute, Oregon Health & Science University, Portland, OR, USA.
- Department of Medical Informatics and Clinical Epidemiology, Oregon Health & Science University, Portland, OR, USA.
- Glaucoma Service, Wills Eye Hospital, Philadelphia, PA, USA.
- Thomas Jefferson University Sidney Kimmel Medical College, Philadelphia, PA, USA.
- Vickie and Jack Farber Vision Research Center, Wills Eye Hospital, Philadelphia, PA, USA.
- Drexel University School of Biomedical Engineering, Science and Health Studies, Philadelphia, PA, USA.
Förderung
- NEI NIH HHS
Zitieren
APA
Gowrisankaran, S., Abbasi, A., Song, X., Schuman, J. S., Wollstein, G., Antony, B. J., & Ishikawa, H. (2025). Normative Variability in Retinal Nerve Fiber Layer Thickness: Does It Matter Where the Peaks Are?. Translational Vision Science & Technology. https://doi.org/10.1167/tvst.14.5.13
Vancouver
Gowrisankaran S, Abbasi A, Song X, Schuman JS, Wollstein G, Antony BJ, et al. Normative Variability in Retinal Nerve Fiber Layer Thickness: Does It Matter Where the Peaks Are?. Translational Vision Science & Technology. 2025. doi:10.1167/tvst.14.5.13
BibTeX
@article{Gowrisankaran2025,
author = {Gowrisankaran, Sowjanya and Abbasi, Ashkan and Song, Xubo and Schuman, Joel S and Wollstein, Gadi and Antony, Bhavna J and Ishikawa, Hiroshi},
title = {Normative Variability in Retinal Nerve Fiber Layer Thickness: Does It Matter Where the Peaks Are?},
journal = {Translational Vision Science & Technology},
year = {2025},
doi = {10.1167/tvst.14.5.13}
}
EUVIMED