Piezo1 Activation by Shear Stress Induces Corneal Epithelial Homeostasis Disruption
Investigative Ophthalmology & Visual Science · 2026
DOI: 10.1167/iovs.67.8.33 ↗Kurz gefasst
Fachartikel in der Zeitschrift Investigative Ophthalmology & Visual Science, 2026. Verfasst von Yufan Li und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi Province, China. Hauptthemen laut MEDLINE: Epithelium, Corneal, Homeostasis, Stress, Mechanical, Ion Channels. Die Arbeit nennt 67 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Purpose
The shear stress induced by abnormal blinking compromises tear film stability. This study aimed to investigate the effects of shear stress on corneal epithelial homeostasis and the role of the mechanosensor Piezo1 in this process.
Methods
In vivo, abnormal ocular surface shear stress was induced in C57BL/6J mice using a controlled blinking model. Corneal damage was assessed via fluorescein staining and tear secretion. In vitro, human SV40 immortalized corneal epithelial cells were exposed to low-level shear stress (L-SS, 2.6 dyn/cm²) or high-level shear stress (H-SS, 7 dyn/cm²), calibrated by computational fluid dynamics simulation. Piezo1 was modulated using Yoda1 and lentivirus-mediated knockdown. Proliferation, migration, pyroptosis, and intercellular junctions were evaluated via EdU, scratch assays, transmission electron microscopy, and immunofluorescence, respectively.
Results
In vivo, increased blinking frequency caused corneal damage, reduced tear secretion, and Piezo1 upregulation. In vitro, both L-SS and H-SS activated Piezo1, modulating proliferation and migration via Ca2+ influx. L-SS upregulated zonula occludens 1 (ZO-1), promoting tight junction formation. In contrast, H-SS induced Piezo1 overactivation, which downregulated ZO-1, compromising barrier function, and upregulated pyroptosis markers (NLRP3, caspase-1, GSDMD, and IL-1β). Notably, these shear stress-induced biological effects were significantly reversed after Piezo1 knockdown.
Conclusions
This study established Piezo1 as a critical mechanosensor that mediates intensity-dependent responses caused by ocular surface shear stress in the corneal epithelial homeostasis. Specifically, Piezo1-mediated mechanotransduction under high-intensity shear stress triggers barrier failure and pyroptosis, highlighting Piezo1 as a promising therapeutic target for managing shear stress-related ocular surface disorders.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Ophthalmology, The First Affiliated Hospital of Xi'an Jiaotong University, Xi'an, Shaanxi Province, China.
- Xi'an Jiaotong University, Xi'an, Shaanxi Province, China.
- State Key Laboratory of Multiphase Flow in Power Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi Province, China.
Zitieren
APA
Li, Y., Hong, Y., Li, W., Li, F., Zhang, M., Zhao, W., Zhao, X., Zhao, F., Sun, Y., Dang, Y., Wang, X., Liu, H., Su, J., & Li, L. (2026). Piezo1 Activation by Shear Stress Induces Corneal Epithelial Homeostasis Disruption. Investigative Ophthalmology & Visual Science. https://doi.org/10.1167/iovs.67.8.33
Vancouver
Li Y, Hong Y, Li W, Li F, Zhang M, Zhao W, et al. Piezo1 Activation by Shear Stress Induces Corneal Epithelial Homeostasis Disruption. Investigative Ophthalmology & Visual Science. 2026. doi:10.1167/iovs.67.8.33
BibTeX
@article{Li2026,
author = {Li, Yufan and Hong, Yijie and Li, Weiwei and Li, Fan and Zhang, Ming and Zhao, Wenxin and Zhao, Xinyi and Zhao, Fanru and Sun, Yishan and Dang, Yufei and Wang, Xin and Liu, Huanyu and Su, Jiaojiao and Li, Li},
title = {Piezo1 Activation by Shear Stress Induces Corneal Epithelial Homeostasis Disruption},
journal = {Investigative Ophthalmology & Visual Science},
year = {2026},
doi = {10.1167/iovs.67.8.33}
}
EUVIMED