EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Segmental Outflow and Trabecular Meshwork Stiffness in an Ocular Hypertensive Mouse Model

Cydney A Wong, A Thomas Read, Guorong Li, Amia Loveless, Nina Sara Fraticelli-Guzmán, Andrew J Feola, Todd Sulchek, W Daniel Stamer, C Ross Ethier

Investigative Ophthalmology & Visual Science · 25.06.2026 · 67 (6) · 51

DOI: 10.1167/iovs.67.6.51 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Investigative Ophthalmology & Visual Science, erschienen am 25.06.2026. Verfasst von Cydney A Wong und 8 weiteren Autor:innen. Beteiligte Einrichtung: Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia, United States. Hauptthemen laut MEDLINE: Trabecular Meshwork, Disease Models, Animal, Ocular Hypertension, Aqueous Humor. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NEI NIH HHS, NIGMS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Elevated IOP due to increased outflow resistance through the trabecular meshwork (TM) is a major risk factor for POAG. Outflow through the TM is segmental, consisting of high-flow (HF) and low-flow (LF) regions. Here, we investigate how ocular hypertension impacts segmental outflow using a dexamethasone (DEX) mouse model and compare TM stiffness between HF and LF regions.

Methods

Nanoparticles containing DEX or vehicle were injected twice weekly in 2- to 4-month-old C57BL/6J mice (n = 14), and the IOP was measured weekly. At week 4, mouse eyes were perfused in vivo with fluorescent nanospheres to assess flow patterns and the circumferential percentage of HF, intermediate-flow, and LF regions in each eye. Sagittal sections were collected from HF and LF regions, and atomic force microscopy was used to measure tissue stiffness. Immunofluorescent labeling was used to compare fibronectin and alpha-smooth muscle actin protein levels.

Results

DEX treatment significantly elevated the IOP by an average of 33.3% and altered tracer distribution but not the percentage of HF and LF regions around the circumference. No significant differences in TM stiffness were detected between DEX-treated and control mice, or between HF and LF regions. Increased fibronectin in LF regions of DEX-treated eyes suggested subtle TM structural changes that were not detected by atomic force microscopy.

Conclusions

DEX alters segmental flow distribution and may impact cell contractility rather than ECM stiffness to cause IOP elevation in young mice. These findings better characterize the nature of segmental outflow and TM mechanics in this model of steroid-induced glaucoma.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Trabecular MeshworkDisease Models, AnimalOcular HypertensionAqueous HumorAnimalsMiceMice, Inbred C57BLDexamethasoneIntraocular PressureActinsGlucocorticoidsFibronectinsMicroscopy, Atomic ForceFluorescent Antibody Technique, IndirectElasticityNanoparticlesMale

Substanzen

DexamethasoneActinsGlucocorticoidsFibronectinsalpha-smooth muscle actin, mouseActa2 protein, mouse

Autor:innen und Institutionen

  • Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia, United States.
  • Department of Ophthalmology, Emory University, Atlanta, Georgia, United States.
  • Department of Ophthalmology, Duke University, Durham, North Carolina, United States.
  • Department of Psychology, Spelman College, Atlanta, Georgia, United States.
  • George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia, United States.
  • Bioengineering Interdisciplinary Program, Georgia Institute of Technology, Atlanta, Georgia, United States.

Förderung

  • NEI NIH HHS
  • NIGMS NIH HHS

Zitieren

APA

Wong, C. A., Read, A. T., Li, G., Loveless, A., Fraticelli-Guzmán, N. S., Feola, A. J., Sulchek, T., Stamer, W. D., & Ethier, C. R. (2026). Segmental Outflow and Trabecular Meshwork Stiffness in an Ocular Hypertensive Mouse Model. Investigative Ophthalmology & Visual Science, 67(6), 51. https://doi.org/10.1167/iovs.67.6.51

Vancouver

Wong CA, Read AT, Li G, Loveless A, Fraticelli-Guzmán NS, Feola AJ, et al. Segmental Outflow and Trabecular Meshwork Stiffness in an Ocular Hypertensive Mouse Model. Investigative Ophthalmology & Visual Science. 2026;67(6):51. doi:10.1167/iovs.67.6.51

BibTeX
@article{Wong2026,
  author = {Wong, Cydney A and Read, A Thomas and Li, Guorong and Loveless, Amia and Fraticelli-Guzmán, Nina Sara and Feola, Andrew J and Sulchek, Todd and Stamer, W Daniel and Ethier, C Ross},
  title = {Segmental Outflow and Trabecular Meshwork Stiffness in an Ocular Hypertensive Mouse Model},
  journal = {Investigative Ophthalmology & Visual Science},
  year = {2026},
  volume = {67},
  number = {6},
  pages = {51},
  doi = {10.1167/iovs.67.6.51}
}
Kostenlos starten →