Ultrasound-Enhanced Retinal Delivery of Engineered Viral Vectors
Investigative Ophthalmology & Visual Science · 2026-11-03 · 67 (13) · 6
DOI: 10.1167/iovs.67.13.6 ↗At a glance
Journal article in Investigative Ophthalmology & Visual Science, published on 2026-11-03. Written by Schuyler Link and 6 co-authors. Institution: Department of Bioengineering, Rice University, Houston, Texas, United States. Major MEDLINE topics: Genetic Vectors, Dependovirus, Genetic Therapy, Retina. 82 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: NEI NIH HHS.
Abstract (original language)
Purpose
The goal of this study was to examine focused ultrasound blood-retina barrier opening (FUS-BRBO) as a method to deliver gene therapy to the eye. We compared AAV.FUS.3, an engineered variant optimized for FUS-enhanced delivery to the central nervous system, and AAV9 for their utility as neuronal gene vectors.
Methods
Mouse eyes were insonated by 4.667 MHz FUS in a custom-designed nosecone. Evans blue dye was administered intravenously to verify the presence of blood-retina barrier opening. Once BRBO was demonstrated, viral vectors were administered before ultrasound scanning to allow crossing into the retina. Viral tropism among different cell types was analyzed, and structural changes were investigated.
Results
FUS-BRBO was achieved across a range of pressures. FUS-BRBO allowed for retinal transduction of systemically administered viral vectors. We found 2.1-fold improvement of transduction of AAV.FUS.3 over AAV9 in the insonated area and 19.5-fold improvement over the uninsonated retina. Within that area, the ganglion cell layer showed the highest levels of transduction at 22% for AAV.FUS. No gross tissue damage was noted.
Conclusions
FUS-BRBO has the potential to non-surgically deliver AAV-based vectors to spatially-defined regions of the retina. AAV.FUS.3 showed significantly improved transduction over AAV9 at the same dose. Further research to improve efficiency of delivery to the outer retina could expand utility of FUS-BRBO.
Subjects
MeSH terms (MEDLINE)
Authors and institutions
- Department of Bioengineering, Rice University, Houston, Texas, United States.
- Neuroengineering Initiative, Rice University, Houston, Texas, United States.
- Medical Scientist Training Program, Baylor College of Medicine, Houston, Texas, United States.
- Department of Neuroscience, Rice University, Houston, Texas, United States.
- Department of Ophthalmology, Baylor College of Medicine, Houston, Texas, United States.
- Department of Neuroscience, Baylor College of Medicine, Houston, Texas, United States.
Funding
- NEI NIH HHS
Cite
APA
Link, S., Fan, K., Adame, J., Keehn, C., Shen, G., Frankfort, B. J., & Szablowski, J. (2026). Ultrasound-Enhanced Retinal Delivery of Engineered Viral Vectors. Investigative Ophthalmology & Visual Science, 67(13), 6. https://doi.org/10.1167/iovs.67.13.6
Vancouver
Link S, Fan K, Adame J, Keehn C, Shen G, Frankfort BJ, et al. Ultrasound-Enhanced Retinal Delivery of Engineered Viral Vectors. Investigative Ophthalmology & Visual Science. 2026;67(13):6. doi:10.1167/iovs.67.13.6
BibTeX
@article{Link2026,
author = {Link, Schuyler and Fan, Kara and Adame, Jesus and Keehn, Caroline and Shen, Guofu and Frankfort, Benjamin J and Szablowski, Jerzy},
title = {Ultrasound-Enhanced Retinal Delivery of Engineered Viral Vectors},
journal = {Investigative Ophthalmology & Visual Science},
year = {2026},
volume = {67},
number = {13},
pages = {6},
doi = {10.1167/iovs.67.13.6}
}
EUVIMED