Axial Length-Refractive Error Dissociation in High Myopia Following Treatment-Warranted Retinopathy of Prematurity: Evidence for Persistent Axial Elongation
Investigative Ophthalmology & Visual Science · 17.11.2026 · 67 (13) · 30
DOI: 10.1167/iovs.67.13.30 ↗Kurz gefasst
Fachartikel in der Zeitschrift Investigative Ophthalmology & Visual Science, erschienen am 17.11.2026. Verfasst von Qi Yan und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Children's Hospital of Soochow University, Suzhou, China. Hauptthemen laut MEDLINE: Axial Length, Eye, Macula Lutea, Myopia. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Purpose
To characterize 5-year regional redistribution of fundus tessellation (FT) and its association with axial elongation and to conduct a post hoc exploratory assessment of whether baseline FT measures predict future axial elongation.
Methods
This cohort included 528 children examined in grades 1 and 6 of the Nanjing Eye Study. Fundus tessellation density (FTD) was quantified using a fixed artificial intelligence pipeline. After projective registration, longitudinal measurements used common overlapping regions derived from 6-mm-diameter fovea-centered and 4-mm-diameter optic disc-centered circles. FT patterns were classified as no regional FT, peripapillary-dominant FT, or macular-dominant FT.
Results
Mean axial length increased from 22.97 to 24.59 mm. Macular FTD increased from 0.014 to 0.025 (P < 0.001), whereas peripapillary FTD decreased from 0.024 to 0.015 (P < 0.001); macular-dominant FT increased from 25.9% to 47.3%. Compared with stable no regional FT, greater axial elongation occurred with the transition from peripapillary-dominant to macular-dominant FT (β = 0.456 mm; 95% confidence interval [CI,] 0.260-0.651; P < 0.001) and those who remained macular-dominant (β = 0.427 mm; 95% CI, 0.224-0.631; P < 0.001). Within baseline peripapillary-dominant eyes, the transition to macular dominance was associated with a 0.300-mm greater adjusted elongation than stable peripapillary dominance. In post hoc exploratory cross-validation, baseline FTD did not meaningfully improve prediction of future axial elongation beyond conventional clinical variables.
Conclusions
FT in children showed macularward redistribution during ocular growth. This redistribution was associated with greater axial elongation and may represent a dynamic imaging phenotype of posterior pole remodeling rather than a standalone baseline predictive biomarker.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Ophthalmology, Children's Hospital of Soochow University, Suzhou, China.
- Changzhou Hygiene Vocational Technology College, Changzhou, China.
- Department of Ophthalmology, Nanjing First Hospital, Nanjing Medical University, Nanjing, China.
- EVision Technology (Beijing) Co., Ltd., Beijing, China.
- Department of Ophthalmology, The First Affiliated Hospital with Nanjing Medical University, Nanjing, China.
Zitieren
APA
Yan, Q., Qian, Y., Li, R., Wang, X., Ling, S., Dong, Z., Zhu, X., Zhou, C., Zhu, H., Liu, H., & Huang, D. (2026). Axial Length-Refractive Error Dissociation in High Myopia Following Treatment-Warranted Retinopathy of Prematurity: Evidence for Persistent Axial Elongation. Investigative Ophthalmology & Visual Science, 67(13), 30. https://doi.org/10.1167/iovs.67.13.30
Vancouver
Yan Q, Qian Y, Li R, Wang X, Ling S, Dong Z, et al. Axial Length-Refractive Error Dissociation in High Myopia Following Treatment-Warranted Retinopathy of Prematurity: Evidence for Persistent Axial Elongation. Investigative Ophthalmology & Visual Science. 2026;67(13):30. doi:10.1167/iovs.67.13.30
BibTeX
@article{Yan2026,
author = {Yan, Qi and Qian, Yingxiao and Li, Rui and Wang, Xi and Ling, Saiguang and Dong, Zhou and Zhu, Xiaoqi and Zhou, Chenyu and Zhu, Hui and Liu, Hu and Huang, Dan},
title = {Axial Length-Refractive Error Dissociation in High Myopia Following Treatment-Warranted Retinopathy of Prematurity: Evidence for Persistent Axial Elongation},
journal = {Investigative Ophthalmology & Visual Science},
year = {2026},
volume = {67},
number = {13},
pages = {30},
doi = {10.1167/iovs.67.13.30}
}
EUVIMED