Association Between Cilio-Lenticular Distance and Anterior Chamber Depth in Primary Angle-Closure Glaucoma
Investigative Ophthalmology & Visual Science · 2026
DOI: 10.1167/iovs.67.12.64 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Investigative Ophthalmology & Visual Science, 2026. Verfasst von Changrong Lei und 15 weiteren Autor:innen. Beteiligte Einrichtung: National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, China. Hauptthemen laut MEDLINE: Glaucoma, Angle-Closure, Anterior Chamber, Ciliary Body, Lens, Crystalline. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Purpose
To investigate the lens and ciliary spatial characteristics in primary angle-closure glaucoma (PACG) patients using ocular magnetic resonance imaging (MRI), aiming to elucidate the mechanism underlying PACG pathogenesis.
Methods
This is a cross-sectional observational case-control study that used a clinical 3.0T MRI with a specialized coil to acquire binocular images in the axial plane. Quantitative measurements were conducted to obtain anatomical parameters of the lens, ciliary body, and vitreous cavity, including lens equator diameter (LED), cilio-lenticular distance (CLD), ciliary to ciliary distance (CCD), vitreous cavity width, and vitreous cavity depth. Linear mixed effects models were used for statistical analysis.
Result
Twenty-five eyes of 13 PACG patients and 19 eyes of 10 healthy participants were enrolled in this study. The PACG group exhibited a statistically significant larger Sectional Area of Lens (33.72 ± 2.50 mm2 vs. 30.72 ± 2.42 mm2, P = 0.005), lower CCD (9.74 ± 0.45 mm vs. 10.41 ± 0.62 mm, P = 0.003), and lower CLD (0.51 ± 0.09 mm vs. 0.85 ± 0.17 mm, P < 0.001). No differences were found in LED and characteristic parameters of vitreous cavities. CLD demonstrated a high predictive performance for PACG (area under the curve [AUC] = 0.979), approaching that of the classical parameter anterior chamber depth (AUC = 0.993), with both showing statistical significance (P < 0.001).
Conclusions
A smaller CLD correlates with a shallow anterior chamber and indicates a more crowded ciliary-lens configuration, a crucial indictor of PACG.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, China.
- Wenzhou Medical University, Wenzhou, China.
- Changsha Aier Eye Hospital, Changsha, Hunan Province, China.
- Ophthalmology, University of California San Francisco, San Francisco, California, United States.
Zitieren
APA
Lei, C., Zuo, J., Lin, H., Zheng, X., Zhao, F., Yu, Y., Mummaneni, N., Xiong, K., Mao, H., Wang, X., Wang, P., Xie, Y., Le, R., Zhang, S., Han, Y., & Liang, Y. (2026). Association Between Cilio-Lenticular Distance and Anterior Chamber Depth in Primary Angle-Closure Glaucoma. Investigative Ophthalmology & Visual Science. https://doi.org/10.1167/iovs.67.12.64
Vancouver
Lei C, Zuo J, Lin H, Zheng X, Zhao F, Yu Y, et al. Association Between Cilio-Lenticular Distance and Anterior Chamber Depth in Primary Angle-Closure Glaucoma. Investigative Ophthalmology & Visual Science. 2026. doi:10.1167/iovs.67.12.64
BibTeX
@article{Lei2026,
author = {Lei, Changrong and Zuo, Jingjing and Lin, Haishuang and Zheng, Xuanli and Zhao, Fengping and Yu, Yongzhen and Mummaneni, Nikhita and Xiong, Kun and Mao, Huiyan and Wang, Xiaojie and Wang, Peijuan and Xie, Yanqian and Le, Rongrong and Zhang, Shaodan and Han, Ying and Liang, Yuanbo},
title = {Association Between Cilio-Lenticular Distance and Anterior Chamber Depth in Primary Angle-Closure Glaucoma},
journal = {Investigative Ophthalmology & Visual Science},
year = {2026},
doi = {10.1167/iovs.67.12.64}
}
EUVIMED