EUVIMEDScopri EUVIMED
Open access · CC BY-NC-ND 4.0

How “Micro” Is Microperimetry? Characterizing the Effect of Fundus Tracking on the Psychometric Function

Theresa Lipsky, Clara Ehrenzeller, Georg Ansari, Kristina Pfau, Wolf Harmening, Zhichao Wu, Maximilian Pfau

Investigative Ophthalmology & Visual Science · 2026

DOI: 10.1167/iovs.67.10.55 ↗

At a glance

Journal article in Investigative Ophthalmology & Visual Science, 2026. Written by Theresa Lipsky and 6 co-authors. Institution: Department of Ophthalmology, University Hospital Basel, Basel, Switzerland. Major MEDLINE topics: Psychometrics, Visual Field Tests, Fundus Oculi, Visual Fields. 37 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

Purpose

The purpose of this study was to quantify whether fundus tracking in microperimetry improves psychometric parameter estimation (as an in vivo demonstration of improved stimulus-delivery precision), and to derive a psychometrically grounded criterion intensity for suprathreshold (defect-mapping) microperimetry.

Methods

Twenty-five healthy volunteers underwent Macular Integrity Assessment (MAIA)2 microperimetry at five loci referenced to Bruch's membrane opening (BMO): three outside and two inside the blind spot. At each location, frequency-of-seeing (FoS) functions were measured with a method of constant stimuli in four blocks (2 had tracking on and 2 had tracking off). FoS data were fit with a cumulative-Gaussian psychometric function estimating sensitivity, spread, guess, and lapse rate. Tracking effects on m, denoting the sensitivity corresponding to the midpoint of the psychometric function, and s, the spread parameter of the underlying Gaussian, were tested per locus using mixed-effects models. The optimal criterion intensity to separate "non-seeing" from "seeing" loci was derived from FoS fits using posterior predictive simulations.

Results

Tracking had little effect on sensitivity estimates at loci outside the blind spot, but produced lower sensitivity estimates within the blind spot - indicating fewer spurious detections at non-seeing loci (posterior median difference, 95% credible intervals [CrIs] of -1.78 decibel [dB] 95% CrI = -2.58 to -0.94 at locus 4, and -0.75 dB, 95% CrI = -1.71 to 0.15 at locus 5). Tracking was also associated with a smaller spread (steeper FoS curves) at loci 1 to 3, with posterior median differences of -0.13 dB, 95% CrIs = -0.28 to 0.02, -0.27 dB, 95% CrI = -0.43 to -0.12, and -0.25 dB, 95% CrI = -0.42 to -0.07, respectively. Without tracking, false-positive responses were more frequent when fixation shifts displaced stimuli toward the "seeing" retina. Simulation-based analysis identified 13 dB as the nominally optimal criterion intensity for suprathreshold microperimetry (Youden index = 0.74, 95% CrI = 0.70-0.77); a 10 dB criterion yielded comparable discrimination (Youden index = 0.72, 95% CrI = 0.69-0.75).

Conclusions

Even in healthy volunteers with stable fixation, fundus tracking measurably lowered apparent sensitivity at "non-seeing" loci (i.e., reduced spurious responses inside the blind spot) and steepened FoS curves in the "seeing" retina. A criterion intensity in the range of 10 to 16 dB is a defensible choice for separating "seeing" and "non-seeing" retina in suprathreshold (defect-mapping) perimetry paradigms.

Subjects

MeSH terms (MEDLINE)

PsychometricsVisual Field TestsFundus OculiVisual FieldsHumansFemaleAdultMaleSensory ThresholdsYoung AdultHealthy VolunteersMiddle Aged

Authors and institutions

  • Department of Ophthalmology, University Hospital Basel, Basel, Switzerland.
  • Department of Ophthalmology, University Hospital Bonn, Bonn, Germany.
  • https://orcid.org/0009-0002-1718-8612.
  • Nuffield Laboratory of Ophthalmology, Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom.
  • https://orcid.org/0009-0000-5709-4923.
  • https://orcid.org/0009-0008-4693-2061.

Cite

APA

Lipsky, T., Ehrenzeller, C., Ansari, G., Pfau, K., Harmening, W., Wu, Z., & Pfau, M. (2026). How “Micro” Is Microperimetry? Characterizing the Effect of Fundus Tracking on the Psychometric Function. Investigative Ophthalmology & Visual Science. https://doi.org/10.1167/iovs.67.10.55

Vancouver

Lipsky T, Ehrenzeller C, Ansari G, Pfau K, Harmening W, Wu Z, et al. How “Micro” Is Microperimetry? Characterizing the Effect of Fundus Tracking on the Psychometric Function. Investigative Ophthalmology & Visual Science. 2026. doi:10.1167/iovs.67.10.55

BibTeX
@article{Lipsky2026,
  author = {Lipsky, Theresa and Ehrenzeller, Clara and Ansari, Georg and Pfau, Kristina and Harmening, Wolf and Wu, Zhichao and Pfau, Maximilian},
  title = {How “Micro” Is Microperimetry? Characterizing the Effect of Fundus Tracking on the Psychometric Function},
  journal = {Investigative Ophthalmology & Visual Science},
  year = {2026},
  doi = {10.1167/iovs.67.10.55}
}
Start for free →