EUVIMEDOpdag EUVIMED
Open access · CC BY-NC-ND 4.0

The Efficiency and Safety of Oxygen-Supplemented Accelerated Scleral Cross-Linking in Rabbits

Lingling Yan, Ce Wu, Xiaona Liu, Pengfei Han, Jie Zhang, Zhipeng Gao, Xiaona Li, Weiyi Chen

Investigative Ophthalmology & Visual Science · 2025

DOI: 10.1167/iovs.66.6.10 ↗

At a glance

Journal article in Investigative Ophthalmology & Visual Science, 2025. Written by Lingling Yan and 7 co-authors. Institution: Institute of Biomedical Engineering, Collage of Artificial Intelligence Taiyuan University of Technology, Taiyuan, China. Major MEDLINE topics: Sclera, Collagen, Cross-Linking Reagents, Oxygen. Cited 2 times so far (Crossref); 29 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

The purpose of this study was to evaluate the efficacy and safety of accelerated scleral collagen cross-linking (SXL) with supplemental oxygen.

Methods

The rabbit scleral tissues were randomly divided into seven different SXL protocols, including traditional (T)-SXL (3 mW/cm2 for 30 minutes, 3*30) and accelerated (A)-SXL (30 mW/cm2 for 3, 5, or 8 minutes, respectively, with or without supplemental oxygen). The control group received no ultraviolet-A (UVA) radiation. The tangent modulus of scleral strip was determined by uniaxial tensile test. The protocol with better mechanical property and shorter cross-linking time in vitro was selected for immediate safety assessment using electroretinogram (ERG) in vivo, hematoxylin and eosin (H&E) staining and TUNEL assay in vitro.

Results

The tangent modulus was significantly greater in all SXL groups compared to the control group. The equatorial sclera showed a larger stiffening effect than the posterior. In the equatorial sclera, extending the irradiation time in normoxic A-SXL can result in a further enhancement of the stiffening effect. The tangent modulus was enhanced by 92% in the hyperoxic A-SXL group (30*3) compared with the normoxic A-SXL (30*3) group, and achieved the same mechanical performance as the T-SXL group. The oxygen supplementation did not play a role in further improving he stiffening effect at the posterior sclera. The ERG and H&E staining indicated no abnormalities in the sclera and retina. Apoptosis was only observed in the outer layer of the sclera in the A-SXL groups.

Conclusions

A-SXL protocol of 30 mW/cm2 can improve the mechanical properties of the sclera. In particular, the protocol of 30 mW/cm2 for 3 minutes with supplemental oxygen showed excellent cross-linking efficacy with shorter surgical time and was relatively safe.

Subjects

MeSH terms (MEDLINE)

ScleraCollagenCross-Linking ReagentsOxygenAnimalsRabbitsElectroretinographyPhotosensitizing AgentsDisease Models, AnimalUltraviolet RaysRiboflavinIn Situ Nick-End Labeling

Substances

CollagenCross-Linking ReagentsOxygenPhotosensitizing AgentsRiboflavin

Authors and institutions

  • Institute of Biomedical Engineering, Collage of Artificial Intelligence Taiyuan University of Technology, Taiyuan, China.
  • ShanXi Aier Eye Hospital, Taiyuan, China.

Cite

APA

Yan, L., Wu, C., Liu, X., Han, P., Zhang, J., Gao, Z., Li, X., & Chen, W. (2025). The Efficiency and Safety of Oxygen-Supplemented Accelerated Scleral Cross-Linking in Rabbits. Investigative Ophthalmology & Visual Science. https://doi.org/10.1167/iovs.66.6.10

Vancouver

Yan L, Wu C, Liu X, Han P, Zhang J, Gao Z, et al. The Efficiency and Safety of Oxygen-Supplemented Accelerated Scleral Cross-Linking in Rabbits. Investigative Ophthalmology & Visual Science. 2025. doi:10.1167/iovs.66.6.10

BibTeX
@article{Yan2025,
  author = {Yan, Lingling and Wu, Ce and Liu, Xiaona and Han, Pengfei and Zhang, Jie and Gao, Zhipeng and Li, Xiaona and Chen, Weiyi},
  title = {The Efficiency and Safety of Oxygen-Supplemented Accelerated Scleral Cross-Linking in Rabbits},
  journal = {Investigative Ophthalmology & Visual Science},
  year = {2025},
  doi = {10.1167/iovs.66.6.10}
}
Start for free →