Comparison Between MAIA and MP-3 In Healthy Subjects and Patients With Diabetes, Diabetic Retinopathy, and Age-Related Macular Degeneration
Investigative Ophthalmology & Visual Science · 2025
DOI: 10.1167/iovs.66.3.59 ↗At a glance
Vergleichsstudie in Investigative Ophthalmology & Visual Science, 2025. Written by Anna Marmalidou and 13 co-authors. Institution: New England Eye Center, Department of Ophthalmology, Tufts Medical Center, Tufts University School of Medicine, Boston, Massachusetts, United States. Major MEDLINE topics: Diabetic Retinopathy, Macular Degeneration, Diabetes Mellitus, Visual Field Tests. Cited 3 times so far (Crossref); 14 references. The full text is freely available (open access, CC BY-NC-ND 4.0).
Topics: Diabetes mellitus
Abstract (original language)
Purpose
The purpose of this study was to assess the comparability of mean sensitivity (MS) values obtained using the Macular Integrity Assessment (MAIA; CenterVue S.p.A. [iCare], Padova, Italy) and Microperimeter-3 (MP-3; NIDEK CO., Ltd., Gamagori, Japan) microperimetry (MP) devices.
Methods
This cross-sectional study includes subjects with healthy eyes, eyes with diabetes mellitus without diabetic retinopathy (DM no DR), diabetic retinopathy (DR), and non-exudative age-related macular degeneration (AMD). Patients underwent testing on both MAIA and MP-3 MP devices, using a 10-2 macular grid with 68 stimuli and identical parameters. A diagnosis-adjusted linear regression model and mixed modeling mapped MP-3 MS to MAIA MS and Bland-Altman analysis were used to assess the agreement.
Results
One hundred eleven eyes (43 healthy eyes, 14 eyes with DM no DR, 32 eyes with DR, and 22 eyes with AMD) from 80 subjects (age = 57.2 ± 20.3 years) were enrolled. MAIA consistently showed higher MS than MP-3. The MP-3 device detected absolute scotomatous points in more eyes than MAIA (6 eyes [MAIA] vs. 10 eyes [MP-3]). Healthy eyes exhibited stronger agreements than those with DR (P < 0.001) or AMD (P = 0.015). Converting MP-3 to MAIA MS improved agreement and reduced coefficients of repeatability (CoRs) but did not fully account for inter-device variability. MP-3 classified more eyes as having relatively unstable or unstable fixation than MAIA (P = 0.014).
Conclusions
Both devices effectively detect retinal functional changes and scotomas. The conversion methods developed in this study can aid cross-device comparisons, but retinal pathologies (DM and AMD) introduce additional inter-device variability. Future studies incorporating multiple devices should account for this variability in their study design.
Subjects
MeSH terms (MEDLINE)
Authors and institutions
- New England Eye Center, Department of Ophthalmology, Tufts Medical Center, Tufts University School of Medicine, Boston, Massachusetts, United States.
- Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania, United States.
- Boston Image Reading Center, Boston, Massachusetts, United States.
- Department of Ophthalmology and Visual Science, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan.
- Nidek Inc., San Jose, California, United States.
Cite
APA
Marmalidou, A., Siddiqui, H., Jamil, M. U., Woo, K. M., Yaghy, A., Alibhai, A. Y., Takahashi, H., Kaiser, S., Effert, K., Zhao, P. Y., Desai, S. J., Robinson, C. C., Duker, J. S., & Waheed, N. K. (2025). Comparison Between MAIA and MP-3 In Healthy Subjects and Patients With Diabetes, Diabetic Retinopathy, and Age-Related Macular Degeneration. Investigative Ophthalmology & Visual Science. https://doi.org/10.1167/iovs.66.3.59
Vancouver
Marmalidou A, Siddiqui H, Jamil MU, Woo KM, Yaghy A, Alibhai AY, et al. Comparison Between MAIA and MP-3 In Healthy Subjects and Patients With Diabetes, Diabetic Retinopathy, and Age-Related Macular Degeneration. Investigative Ophthalmology & Visual Science. 2025. doi:10.1167/iovs.66.3.59
BibTeX
@article{Marmalidou2025,
author = {Marmalidou, Anna and Siddiqui, Haleema and Jamil, Muhammad Usman and Woo, Kwang Min and Yaghy, Antonio and Alibhai, A Yasin and Takahashi, Hiroyuki and Kaiser, Stephanie and Effert, Keith and Zhao, Peter Y and Desai, Shilpa J and Robinson, Christopher C and Duker, Jay S and Waheed, Nadia K},
title = {Comparison Between MAIA and MP-3 In Healthy Subjects and Patients With Diabetes, Diabetic Retinopathy, and Age-Related Macular Degeneration},
journal = {Investigative Ophthalmology & Visual Science},
year = {2025},
doi = {10.1167/iovs.66.3.59}
}
EUVIMED