EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Horizontal Gaze Tolerance and Its Effects on Visual Sensitivity in Glaucoma

Takashi Nishida, Takuhei Shoji, Robert N Weinreb, Saori Yamaguchi, Izumi Mine, Akane Kosaka, Kei Shinoda

Investigative Ophthalmology & Visual Science · 2025

DOI: 10.1167/iovs.66.1.59 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Investigative Ophthalmology & Visual Science, 2025. Verfasst von Takashi Nishida und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Saitama Medical University, Saitama, Japan. Hauptthemen laut MEDLINE: Visual Fields, Glaucoma, Open-Angle, Fixation, Ocular. Die Arbeit nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study evaluates the effect of 6° horizontal gaze tolerance on visual field mean sensitivity (MS) in patients with glaucoma using a binocular head-mounted automated perimeter, following findings of structural changes in the posterior globe from magnetic resonance imaging and optical coherence tomography.

Methods

In this cross-sectional study, a total of 161 eyes (85 primary open-angle glaucoma [POAG] and 76 healthy) from 117 participants were included. Logistic regression and 1:1 matched analysis assessed the propensity score for glaucoma and healthy eyes, considering age, sex, and axial length as confounders. Visual field tests were performed with the imo perimeter (CREWT Medical Systems, Inc., Tokyo, Japan) at central gaze, 6° abduction, and 6° adduction positions as fixation points. A mixed-effects model was used to compare MS under all conditions.

Results

The analysis included a total of 82 eyes, with 41 POAG and 41 healthy after matching. The mean (standard deviation) age was 68.0 (11.0) years, with a mean deviation of -9.9 (6.6) dB for POAG and -1.0 (1.9) dB for healthy eyes using Humphrey field analysis 24-2. MS did not significantly differ among central gaze (27.0 [1.8] dB), abduction (27.1 [1.9] dB), and adduction (26.9 [2.2] dB) in healthy eyes (P = 0.650). However, MS was significantly lower for adduction (17.2 [5.9] dB) compared to central gaze (18.1 [5.9] dB) and abduction (17.9 [5.9] dB) in glaucoma eyes (P = 0.001 and P = 0.022, respectively).

Conclusions

Horizontal gaze, especially in adduction, significantly reduces visual sensitivity in glaucoma, suggesting a specific vulnerability associated with eye movement. This finding highlights the importance of eye positioning in glaucoma, warranting further investigation of its clinical significance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Visual FieldsGlaucoma, Open-AngleFixation, OcularHumansMaleFemaleCross-Sectional StudiesAgedVisual Field TestsTomography, Optical CoherenceMiddle AgedIntraocular PressureMagnetic Resonance Imaging

Autor:innen und Institutionen

  • Department of Ophthalmology, Saitama Medical University, Saitama, Japan.
  • Hamilton Glaucoma Center, Shiley Eye Institute, Viterbi Family Department of Ophthalmology, University of California San Diego, La Jolla, California, United States.
  • Koedo Eye Institute, Kawagoe, Saitama, Japan.

Zitieren

APA

Nishida, T., Shoji, T., Weinreb, R. N., Yamaguchi, S., Mine, I., Kosaka, A., & Shinoda, K. (2025). Horizontal Gaze Tolerance and Its Effects on Visual Sensitivity in Glaucoma. Investigative Ophthalmology & Visual Science. https://doi.org/10.1167/iovs.66.1.59

Vancouver

Nishida T, Shoji T, Weinreb RN, Yamaguchi S, Mine I, Kosaka A, et al. Horizontal Gaze Tolerance and Its Effects on Visual Sensitivity in Glaucoma. Investigative Ophthalmology & Visual Science. 2025. doi:10.1167/iovs.66.1.59

BibTeX
@article{Nishida2025,
  author = {Nishida, Takashi and Shoji, Takuhei and Weinreb, Robert N and Yamaguchi, Saori and Mine, Izumi and Kosaka, Akane and Shinoda, Kei},
  title = {Horizontal Gaze Tolerance and Its Effects on Visual Sensitivity in Glaucoma},
  journal = {Investigative Ophthalmology & Visual Science},
  year = {2025},
  doi = {10.1167/iovs.66.1.59}
}
Kostenlos starten →