EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Development of a machine learning model using systemic and ophthalmic parameters to detect sleep-disordered breathing in glaucoma patients

Naoki Kiyota, Mai Yamazaki, Noriko Himori, Takahiro Ninomiya, Koki Osada, Takeshi Yabana, Shigeto Maekawa, Satoru Tsuda, Kazuko Omodaka, Yu Yokoyama, Toru Nakazawa

Japanese Journal of Ophthalmology · 2026

DOI: 10.1007/s10384-026-01386-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Japanese Journal of Ophthalmology, 2026. Verfasst von Naoki Kiyota und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan. naoki.kiyota.…. Hauptthemen laut MEDLINE: Sleep Apnea Syndromes, Machine Learning, Glaucoma, Open-Angle, Visual Fields. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science, Co-creation place formation support program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To develop and validate a machine-learning model using systemic and ophthalmic parameters that predicts sleep-disordered breathing (SDB) in patients with open-angle glaucoma (OAG). Study design Retrospective cross-sectional study Methods We analyzed 513 patients with OAG (955 eyes) treated at Seiryo Eye Clinic. All the participants underwent comprehensive ophthalmic examinations, including Humphrey visual field (HVF) testing, and home sleep apnea testing (HSAT) to obtain the 4% oxygen desaturation index (ODI). SDB was operationally defined as ODI-SAS, ie, sleep apnea syndrome (SAS) defined by HSAT-derived 4% ODI ≥15 events per hour. Sixteen algorithms were trained to predict ODI-SAS; model performance was assessed by the area under the receiver operating characteristic curve (ROC–AUC), precision, recall, the F1 score, and the Matthews correlation coefficient (MCC).

Results

One hundred fifty-eight patients (30.80%) met the ODI-SAS criterion. ODI-SAS status was associated with a history of hypertension, higher body mass index, family-reported apnea, shorter axial length, fewer antiglaucoma medications, and worse inferocentral total deviation on HVF (all P < 0.05), but not with self-awareness of snoring or previous SAS diagnosis. A gradient-boosted decision-tree model (CatBoost) achieved the best performance (ROC–AUC 0.86), with precision 0.692, recall 0.711, F1 score 0.701, and MCC 0.543.

Conclusion

Machine-learning models can predict ODI-SAS in glaucoma using systemic risk factors together with ophthalmic features, including inferocentral visual-field defects. Such models may help identify OAG patients who warrant formal sleep evaluation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Sleep Apnea SyndromesMachine LearningGlaucoma, Open-AngleVisual FieldsIntraocular PressureHumansCross-Sectional StudiesFemaleRetrospective StudiesMaleROC CurveAgedMiddle AgedPredictive Learning ModelsVisual Field Tests

Stichwörter der Autor:innen

Machine learningOpen-angle glaucomaSleep apnea syndromeSleep-disordered breathing

Autor:innen und Institutionen

  • Department of Ophthalmology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan. naoki.kiyota.c4@tohoku.ac.jp.
  • Department of Ophthalmology, Tohoku University Graduate School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan.
  • Seiryo Eye Clinic, Miyagi, Japan.
  • Department of Aging Vision Healthcare, Tohoku University Graduate School of Biomedical Engineering, Miyagi, Japan.
  • Department of Ophthalmic Imaging and Information Analytics, Tohoku University Graduate School of Medicine, Miyagi, Japan.
  • Department of Retinal Disease Control, Tohoku University Graduate School of Medicine, Miyagi, Japan.

Förderung

  • Japan Society for the Promotion of Science
  • Co-creation place formation support program

Zitieren

APA

Kiyota, N., Yamazaki, M., Himori, N., Ninomiya, T., Osada, K., Yabana, T., Maekawa, S., Tsuda, S., Omodaka, K., Yokoyama, Y., & Nakazawa, T. (2026). Development of a machine learning model using systemic and ophthalmic parameters to detect sleep-disordered breathing in glaucoma patients. Japanese Journal of Ophthalmology. https://doi.org/10.1007/s10384-026-01386-5

Vancouver

Kiyota N, Yamazaki M, Himori N, Ninomiya T, Osada K, Yabana T, et al. Development of a machine learning model using systemic and ophthalmic parameters to detect sleep-disordered breathing in glaucoma patients. Japanese Journal of Ophthalmology. 2026. doi:10.1007/s10384-026-01386-5

BibTeX
@article{Kiyota2026,
  author = {Kiyota, Naoki and Yamazaki, Mai and Himori, Noriko and Ninomiya, Takahiro and Osada, Koki and Yabana, Takeshi and Maekawa, Shigeto and Tsuda, Satoru and Omodaka, Kazuko and Yokoyama, Yu and Nakazawa, Toru},
  title = {Development of a machine learning model using systemic and ophthalmic parameters to detect sleep-disordered breathing in glaucoma patients},
  journal = {Japanese Journal of Ophthalmology},
  year = {2026},
  doi = {10.1007/s10384-026-01386-5}
}
Kostenlos starten →