Tutorial on Biostatistics: Sample Size and Power Calculation for Ophthalmic Studies With Correlated Binary Eye Outcomes
Investigative Ophthalmology & Visual Science · 2024-07-03 · 65 (8) · 7
DOI: 10.1167/iovs.65.8.7 ↗At a glance
Journal article in Investigative Ophthalmology & Visual Science, published on 2024-07-03. Written by Gui-Shuang Ying and 2 co-authors. Institution: Center for Preventive Ophthalmology and Biostatistics, Department of Ophthalmology, Perelman School of Medicine, University of Pennsylvania, Philadel…. Major MEDLINE topics: Ophthalmology, Biostatistics. Cited 10 times so far (Crossref); 31 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: NEI NIH HHS.
Abstract (original language)
Purpose
To describe and demonstrate sample size and power calculation for ophthalmic studies with a binary outcome from one or both eyes.
Methods
We describe sample size and power calculation for four commonly used eye designs: (1) one-eye design or person-design: one eye per subject or outcome is at person-level; (2) paired design: two eyes per subject and two eyes are in different treatment groups; (3) two-eye design: two eyes per subject and both eyes are in the same treatment group; and (4) mixture design: mixture of one eye and two eyes per subject. For each design, we demonstrate sample size and power calculations in real ophthalmic studies.
Results
Using formulas and commercial or free statistical packages including SAS, STATA, R, and PS, we calculated sample size and power. We demonstrated that different statistical packages require different parameters and provide similar, yet not identical, results. We emphasize that studies using data from two eyes of a subject need to account for the intereye correlation for appropriate sample size and power calculations. We demonstrate the gain in efficiency in designs that include two eyes of a subject compared to one-eye designs.
Conclusions
Ophthalmic studies use different eye designs that include one or both eyes in the same or different treatment groups. Appropriate sample size and power calculations depend on the eye design and should account for intereye correlation when two eyes from some or all subjects are included in a study. Calculations can be executed using formulas and commercial or free statistical packages.
Subjects
MeSH terms (MEDLINE)
Authors and institutions
- Center for Preventive Ophthalmology and Biostatistics, Department of Ophthalmology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, United States.
- Division of Preventive Medicine and the Channing Lab, Department of Medicine, Brigham and Women's Hospital, Boston, Massachusetts, United States.
Funding
- NEI NIH HHS
Cite
APA
Ying, G. S., Glynn, R. J., & Rosner, B. (2024). Tutorial on Biostatistics: Sample Size and Power Calculation for Ophthalmic Studies With Correlated Binary Eye Outcomes. Investigative Ophthalmology & Visual Science, 65(8), 7. https://doi.org/10.1167/iovs.65.8.7
Vancouver
Ying GS, Glynn RJ, Rosner B. Tutorial on Biostatistics: Sample Size and Power Calculation for Ophthalmic Studies With Correlated Binary Eye Outcomes. Investigative Ophthalmology & Visual Science. 2024;65(8):7. doi:10.1167/iovs.65.8.7
BibTeX
@article{Ying2024,
author = {Ying, Gui-Shuang and Glynn, Robert J and Rosner, Bernard},
title = {Tutorial on Biostatistics: Sample Size and Power Calculation for Ophthalmic Studies With Correlated Binary Eye Outcomes},
journal = {Investigative Ophthalmology & Visual Science},
year = {2024},
volume = {65},
number = {8},
pages = {7},
doi = {10.1167/iovs.65.8.7}
}
EUVIMED