Influencing Factors on Pupillary Light Responses as a Biomarker for Local Retinal Function in a Large Normative Cohort
Investigative Ophthalmology & Visual Science · 2024
DOI: 10.1167/iovs.65.6.3 ↗At a glance
Journal article in Investigative Ophthalmology & Visual Science, 2024. Written by Ricarda Jendritza and 10 co-authors. Institution: Pupil Research Group at the Centre for Ophthalmology, University of Tuebingen, Tuebingen, Germany. Major MEDLINE topics: Tomography, Optical Coherence, Pupil, Reflex, Pupillary. Cited 6 times so far (Crossref); 50 references. The full text is freely available (open access, CC BY 4.0).
Abstract (original language)
Purpose
Investigating influencing factors on the pupillary light response (PLR) as a biomarker for local retinal function by providing epidemiological data of a large normative collective and to establish a normative database for the evaluation of chromatic pupil campimetry (CPC).
Methods
Demographic and ophthalmologic characteristics were captured and PLR parameters of 150 healthy participants (94 women) aged 18 to 79 years (median = 46 years) were measured with L-cone- and rod-favoring CPC protocols. Linear-mixed effects models were performed to determine factors influencing the PLR and optical coherence tomography (OCT) data were correlated with the pupillary function volume.
Results
Relative maximal constriction amplitude (relMCA) and latency under L-cone- and rod-favoring stimulation were statistically significantly affected by the stimulus eccentricity (P < 0.0001, respectively). Iris color and gender did not affect relMCA or latency significantly; visual hemifield, season, and daytime showed only minor influence under few stimulus conditions. Age had a statistically significant effect on latency under rod-specific stimulation with a latency prolongation ≥60 years. Under photopic and scotopic conditions, baseline pupil diameter declined significantly with increasing age (P < 0.0001, respectively). Pupillary function volume and OCT data were not correlated relevantly.
Conclusions
Stimulus eccentricity had the most relevant impact on relMCA and latency of the PLR during L-cone- and rod-favoring stimulation. Latency is prolonged ≥60 years under scotopic conditions. Considering the large study collective, a representative normative database for relMCA and latency as valid readout parameters for L-cone- and rod-favoring stimulation could be established. This further validates the usability of the PLR in CPC as a biomarker for local retinal function.
Subjects
MeSH terms (MEDLINE)
Substances
Authors and institutions
- Pupil Research Group at the Centre for Ophthalmology, University of Tuebingen, Tuebingen, Germany.
- University Eye Hospital, Centre for Ophthalmology, University of Tuebingen, Tuebingen, Germany.
- Center for Rare Eye Diseases, University of Tuebingen, Tuebingen, Germany.
- Institute for Ophthalmic Research, Centre for Ophthalmology, University of Tuebingen, Tuebingen, Germany.
Cite
APA
Jendritza, R., Stingl, K., Strasser, T., Jung, R., Tonagel, F., Richter, P., Sonntag, A., Peters, T., Wilhelm, H., Wilhelm, B., & Kelbsch, C. (2024). Influencing Factors on Pupillary Light Responses as a Biomarker for Local Retinal Function in a Large Normative Cohort. Investigative Ophthalmology & Visual Science. https://doi.org/10.1167/iovs.65.6.3
Vancouver
Jendritza R, Stingl K, Strasser T, Jung R, Tonagel F, Richter P, et al. Influencing Factors on Pupillary Light Responses as a Biomarker for Local Retinal Function in a Large Normative Cohort. Investigative Ophthalmology & Visual Science. 2024. doi:10.1167/iovs.65.6.3
BibTeX
@article{Jendritza2024,
author = {Jendritza, Ricarda and Stingl, Krunoslav and Strasser, Torsten and Jung, Ronja and Tonagel, Felix and Richter, Paul and Sonntag, Anton and Peters, Tobias and Wilhelm, Helmut and Wilhelm, Barbara and Kelbsch, Carina},
title = {Influencing Factors on Pupillary Light Responses as a Biomarker for Local Retinal Function in a Large Normative Cohort},
journal = {Investigative Ophthalmology & Visual Science},
year = {2024},
doi = {10.1167/iovs.65.6.3}
}
EUVIMED