EUVIMEDDescobrir EUVIMED
Open access · CC BY-NC-ND 4.0

Visual Tracking in Amblyopia: A Continuous Psychophysical Approach

Cheng Li, Yan Yang, Jinli Zhu, Yijin Han, Jia He, Jun Wang, Yufan Feng, Junli Yuan, Xiaolin Huang, Renjie Liu, Hanyi Zhang, Xiaowei Ruan and 1 more

Investigative Ophthalmology & Visual Science · 2024

DOI: 10.1167/iovs.65.5.7 ↗

At a glance

Journal article in Investigative Ophthalmology & Visual Science, 2024. Written by Cheng Li and 12 co-authors. Institution: School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, China. Major MEDLINE topics: Amblyopia, Visual Acuity. Cited 3 times so far (Crossref); 85 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

ResumoSubjectsDados bibliográficosCiteRelated studies

Abstract (original language)

Purpose

This study aimed to explore the underlying mechanisms of the observed visuomotor deficit in amblyopia.

Methods

Twenty-four amblyopic (25.8 ± 3.8 years; 15 males) and 22 normal participants (25.8 ± 2.1 years; 8 males) took part in the study. The participants were instructed to continuously track a randomly moving Gaussian target on a computer screen using a mouse. In experiment 1, the participants performed the tracking task at six different target sizes. In experiments 2 and 3, they were asked to track a target with the contrast adjusted to individual's threshold. The tracking performance was represented by the kernel function calculated as the cross-correlation between the target and mouse displacements. The peak, latency, and width of the kernel were extracted and compared between the two groups.

Results

In experiment 1, target size had a significant effect on the kernel peak (F(1.649, 46.170) = 200.958, P = 4.420 × 10-22). At the smallest target size, the peak in the amblyopic group was significantly lower than that in the normal group (0.089 ± 0.023 vs. 0.107 ± 0.020, t(28) = -2.390, P = 0.024) and correlated with the contrast sensitivity function (r = 0.739, P = 0.002) in the amblyopic eyes. In experiments 2 and 3, with equally visible stimuli, there were still differences in the kernel between the two groups (all Ps < 0.05).

Conclusions

When stimulus visibility was compensated, amblyopic participants still showed significantly poorer tracking performance.

Subjects

MeSH terms (MEDLINE)

AmblyopiaVisual AcuityHumansMaleFemaleAdultYoung AdultPsychophysicsMotion PerceptionContrast SensitivityEye Movements

Authors and institutions

  • School of Ophthalmology and Optometry and Eye Hospital, Wenzhou Medical University, Wenzhou, China.
  • Civil Aviation General Hospital, Beijing, China.
  • National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, China.
  • State Key Laboratory of Ophthalmology, Optometry and Vision Science, Eye Hospital, Wenzhou Medical University, Wenzhou, China.

Cite

APA

Li, C., Yang, Y., Zhu, J., Han, Y., He, J., Wang, J., Feng, Y., Yuan, J., Huang, X., Liu, R., Zhang, H., Ruan, X., & Hou, F. (2024). Visual Tracking in Amblyopia: A Continuous Psychophysical Approach. Investigative Ophthalmology & Visual Science. https://doi.org/10.1167/iovs.65.5.7

Vancouver

Li C, Yang Y, Zhu J, Han Y, He J, Wang J, et al. Visual Tracking in Amblyopia: A Continuous Psychophysical Approach. Investigative Ophthalmology & Visual Science. 2024. doi:10.1167/iovs.65.5.7

BibTeX
@article{Li2024,
  author = {Li, Cheng and Yang, Yan and Zhu, Jinli and Han, Yijin and He, Jia and Wang, Jun and Feng, Yufan and Yuan, Junli and Huang, Xiaolin and Liu, Renjie and Zhang, Hanyi and Ruan, Xiaowei and Hou, Fang},
  title = {Visual Tracking in Amblyopia: A Continuous Psychophysical Approach},
  journal = {Investigative Ophthalmology & Visual Science},
  year = {2024},
  doi = {10.1167/iovs.65.5.7}
}
Start for free →