Intraocular Pressure While Using Gonioscopy, SLT, and Laser Iridotomy Lenses: An Ex Vivo Study
Investigative Ophthalmology & Visual Science · 2024
DOI: 10.1167/iovs.65.5.13 ↗Kurz gefasst
Fachartikel in der Zeitschrift Investigative Ophthalmology & Visual Science, 2024. Verfasst von Ticiana De Francesco und 4 weiteren Autor:innen. Beteiligte Einrichtung: John Moran Eye Center, University of Utah, Salt Lake City, Utah, United States. Hauptthemen laut MEDLINE: Gonioscopy, Intraocular Pressure, Laser Therapy, Iris. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Purpose
The purpose of this study was to measure intraocular pressure (IOP) elevation while applying standard gonioscopy, selective laser trabeculoplasty (SLT), and laser iridotomy procedural lenses.
Methods
Twelve cadaver eyes were mounted to a custom apparatus and cannulated with a pressure transducer which measured IOP. The apparatus was mounted to a load cell which measured the force on the eye. Six ophthalmologists performed simulated gonioscopy (Sussman 4 mirror lens), SLT (Latina lens), and laser iridotomy (Abraham lens) while a computer recorded IOP (mm Hg) and force (grams). The main outcome measures were IOP and force applied to the eye globe during ophthalmic diagnostics and procedures.
Results
The average IOP's during gonioscopy, SLT, and laser iridotomy were 43.2 ± 16.9 mm Hg, 39.8 ± 9.9 mm Hg, and 42.7 ± 12.6 mm Hg, respectively. The mean force on the eye for the Sussman, Latina, and Abraham lens was 40.3 ± 26.4 grams, 66.7 ± 29.8 grams, and 65.5 ± 35.9 grams, respectively. The average force applied to the eye by the Sussman lens was significantly lower than both the Latina lens (P = 0.0008) and the Abraham lens (P = 0.001). During gonioscopy indentation, IOP elevated on average to 80.5 ± 22.6 mm Hg. During simulated laser iridotomy tamponade, IOP elevated on average to 82.3 ± 27.2 mm Hg.
Conclusions
In cadaver eyes, the use of standard ophthalmic procedural lenses elevated IOP by approximately 20 mm Hg above baseline.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- John Moran Eye Center, University of Utah, Salt Lake City, Utah, United States.
- Clinica de Olhos De Francesco, Fortaleza, Brazil.
- Hospital de Olhos Leiria de Andrade (HOLA), Fortaleza, Brazil.
- ViaLase Inc., Aliso Viejo, California, United States.
- Department of Ophthalmology, University of California, Irvine, Irvine, California, United States.
- Department of Ophthalmology & Vision Sciences, University of Toronto, Toronto, Ontario, Canada.
Zitieren
APA
De Francesco, T., Mikula, E., Lummis, W., Sangalang, N., & Ahmed, I. I. K. (2024). Intraocular Pressure While Using Gonioscopy, SLT, and Laser Iridotomy Lenses: An Ex Vivo Study. Investigative Ophthalmology & Visual Science. https://doi.org/10.1167/iovs.65.5.13
Vancouver
De Francesco T, Mikula E, Lummis W, Sangalang N, Ahmed IIK. Intraocular Pressure While Using Gonioscopy, SLT, and Laser Iridotomy Lenses: An Ex Vivo Study. Investigative Ophthalmology & Visual Science. 2024. doi:10.1167/iovs.65.5.13
BibTeX
@article{DeFrancesco2024,
author = {De Francesco, Ticiana and Mikula, Eric and Lummis, Wes and Sangalang, Nathan and Ahmed, Iqbal Ike K},
title = {Intraocular Pressure While Using Gonioscopy, SLT, and Laser Iridotomy Lenses: An Ex Vivo Study},
journal = {Investigative Ophthalmology & Visual Science},
year = {2024},
doi = {10.1167/iovs.65.5.13}
}
EUVIMED