Multicenter Normative Data for Mesopic Microperimetry
Investigative Ophthalmology & Visual Science · 2024
DOI: 10.1167/iovs.65.12.27 ↗At a glance
Multizentrische Studie in Investigative Ophthalmology & Visual Science, 2024. Written by Maximilian Pfau and 8 co-authors. Institution: Department of Ophthalmology, University Hospital Basel, Basel, Switzerland. Major MEDLINE topics: Visual Field Tests, Visual Fields. Cited 15 times so far (Crossref); 57 references. The full text is freely available (open access, CC BY-NC-ND 4.0).
Abstract (original language)
Purpose
The purpose of this study was to provide a large, multi-center normative dataset for the Macular Integrity Assessment (MAIA) microperimeter and compare the goodness-of-fit and prediction interval calibration-error for a panel of hill-of-vision models.
Methods
Microperimetry examinations of healthy eyes from five independent study groups and one previously available dataset were included (1137 tests from 531 eyes of 432 participants [223 women and 209 men]). Linear mixed models (LMMs) were fitted to the data to obtain interpretable hill-of-vision models. A panel of regression models to predict normative data was compared using cross-validation with site-wise splits. The mean absolute error (MAE) and miscalibration area (area between the calibration curve and the ideal diagonal) were evaluated as the performance measures.
Results
Based on the parameters "participant age," "eccentricity from the fovea," "overlap with the central fixation target," and "eccentricity along the four principal meridians," a Bayesian mixed model had the lowest MAE (2.13 decibel [dB]; 95% confidence interval [CI] = 1.9-2.36 dB) and miscalibration area (0.13; 95% CI = 0.07-0.19). However, a parsimonious linear model provided a comparable MAE (2.17 dB; 95% CI = 1.93-2.4 dB) and a similar miscalibration area (0.14; 95% CI = 0.08-0.2).
Conclusions
Normal variations in visual sensitivity on mesopic microperimetry can be effectively explained by a linear model that includes age and eccentricity. The dataset and a code vignette are provided for estimating normative values across a large range of retinal locations, applicable to customized testing patterns.
Subjects
MeSH terms (MEDLINE)
Authors and institutions
- Department of Ophthalmology, University Hospital Basel, Basel, Switzerland.
- Institute of Molecular and Clinical Ophthalmology Basel, Basel, Switzerland.
- Department of Ophthalmology, University of Bonn, Bonn, Germany.
- https://orcid.org/0000-0001-9761-9640.
- Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom.
- Vision and Eye Research Institute, Anglia Ruskin University, Cambridge, United Kingdom.
Cite
APA
Pfau, M., Jolly, J. K., Charng, J., von der Emde, L., Müller, P. L., Ansari, G., Pfau, K., Chen, F. K., & Wu, Z. (2024). Multicenter Normative Data for Mesopic Microperimetry. Investigative Ophthalmology & Visual Science. https://doi.org/10.1167/iovs.65.12.27
Vancouver
Pfau M, Jolly JK, Charng J, von der Emde L, Müller PL, Ansari G, et al. Multicenter Normative Data for Mesopic Microperimetry. Investigative Ophthalmology & Visual Science. 2024. doi:10.1167/iovs.65.12.27
BibTeX
@article{Pfau2024,
author = {Pfau, Maximilian and Jolly, Jasleen K and Charng, Jason and von der Emde, Leon and Müller, Philipp L and Ansari, Georg and Pfau, Kristina and Chen, Fred K and Wu, Zhichao},
title = {Multicenter Normative Data for Mesopic Microperimetry},
journal = {Investigative Ophthalmology & Visual Science},
year = {2024},
doi = {10.1167/iovs.65.12.27}
}
EUVIMED