EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Lifelong Changes in the Choroidal Thickness, Refractive Status, and Ocular Dimensions in C57BL/6J Mouse

Tao Tang, Chi Ren, Yi Cai, Yan Li, Kai Wang, Mingwei Zhao

Investigative Ophthalmology & Visual Science · 18.10.2024 · 65 (12) · 26

DOI: 10.1167/iovs.65.12.26 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Investigative Ophthalmology & Visual Science, erschienen am 18.10.2024. Verfasst von Tao Tang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology & Clinical Centre of Optometry, Peking University People's Hospital, Beijing, China. Hauptthemen laut MEDLINE: Mice, Inbred C57BL, Choroid, Tomography, Optical Coherence, Refraction, Ocular. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To investigate the changes in choroidal thickness (ChT), refractive status, and ocular dimensions in the mouse eye in vivo using updated techniques and instrumentation.

Methods

High-resolution swept-source optical coherence tomography (SS-OCT), eccentric infrared photoretinoscopy, and custom real-time optical coherence tomography were used to analyze choroidal changes, refractive changes and ocular growth in C57BL/6J mice from postnatal day (P) 21 to month 22.

Results

The ChT gradually increased with age, with the thickest region in the para-optic nerve head and thinning outward, and the temporal ChT was globally thicker than the nasal ChT. Retinal thickness remained stable until 4 months and subsequently decreased. The average spherical equivalent refraction error was -4.81 ± 2.71 diopters (D) at P21, which developed into emmetropia by P32, reached a hyperopic peak (+5.75 ± 1.38 D) at P82 and returned to +0.66 ± 1.86 D at 22 months. Central corneal thickness, anterior chamber depth, lens thickness, and axial length (AL) increased continuously before 4 months, but subsequently exhibited subtle changes. Vitreous chamber depth decreased with lens growth. ChT was correlated significantly with the ocular parameters (except for retinal thickness) before the age of 4 months, but these correlations diminished after 4 months. Furthermore, for mice younger than 4 months, the difference in the ChT, especially temporal ChT, between the two eyes contributed most to that of axial length and spherical equivalent refraction error.

Conclusions

Four months could be a watershed age in the growth of mouse eyes. Large-span temporal recordings of refraction, ocular dimensions, and choroidal changes provided references for the study of the physiological and pathological mechanisms responsible for myopia.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Mice, Inbred C57BLChoroidTomography, Optical CoherenceRefraction, OcularAxial Length, EyeAnimalsMiceAgingRetinoscopyMaleRetina

Autor:innen und Institutionen

  • Department of Ophthalmology & Clinical Centre of Optometry, Peking University People's Hospital, Beijing, China.
  • Institute of Medical Technology, Peking University Health Science Center, Beijing, China.
  • College of Optometry, Peking University Health Science Center, Beijing, China.
  • Eye Disease and Optometry Institute, Peking University People's Hospital, Beijing, China.
  • Beijing Key Laboratory of the Diagnosis and Therapy of Retinal and Choroid Diseases, Beijing, China.
  • The Eye Hospital of Wenzhou Medical University, Wenzhou Medical University, Hangzhou, Zhejiang, China.

Zitieren

APA

Tang, T., Ren, C., Cai, Y., Li, Y., Wang, K., & Zhao, M. (2024). Lifelong Changes in the Choroidal Thickness, Refractive Status, and Ocular Dimensions in C57BL/6J Mouse. Investigative Ophthalmology & Visual Science, 65(12), 26. https://doi.org/10.1167/iovs.65.12.26

Vancouver

Tang T, Ren C, Cai Y, Li Y, Wang K, Zhao M. Lifelong Changes in the Choroidal Thickness, Refractive Status, and Ocular Dimensions in C57BL/6J Mouse. Investigative Ophthalmology & Visual Science. 2024;65(12):26. doi:10.1167/iovs.65.12.26

BibTeX
@article{Tang2024,
  author = {Tang, Tao and Ren, Chi and Cai, Yi and Li, Yan and Wang, Kai and Zhao, Mingwei},
  title = {Lifelong Changes in the Choroidal Thickness, Refractive Status, and Ocular Dimensions in C57BL/6J Mouse},
  journal = {Investigative Ophthalmology & Visual Science},
  year = {2024},
  volume = {65},
  number = {12},
  pages = {26},
  doi = {10.1167/iovs.65.12.26}
}
Kostenlos starten →