EUVIMEDObjevte EUVIMED
VergleichsstudieOpen access · CC BY-NC-ND 4.0

Diagnostic Performance for Detection of Glaucomatous Structural Damage Using Pixelwise Analysis of Retinal Thickness Measurements

Hongli Yang, Juan Reynaud, Glen P Sharpe, Dawn Jennings, Cindy Albert, Trinity Holthausen, Xiue Jiang, Shaban Demirel, Steven L Mansberger, Marcelo T Nicolela, Stuart K Gardiner, Balwantray C Chauhan and 2 more

Investigative Ophthalmology & Visual Science · 2024

DOI: 10.1167/iovs.65.12.17 ↗

At a glance

Vergleichsstudie in Investigative Ophthalmology & Visual Science, 2024. Written by Hongli Yang and 13 co-authors. Institution: Optic Nerve Head Research Laboratory, Devers Eye Institute, Legacy Research Institute, Portland, Oregon, United States. Major MEDLINE topics: Tomography, Optical Coherence, Retinal Ganglion Cells, Nerve Fibers, ROC Curve. Cited 1 times so far (Crossref); 48 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: NEI NIH HHS.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Purpose

To compare the diagnostic accuracy of thickness measurements of individual and combined macular retinal layers to discriminate 188 glaucomatous and 148 glaucoma suspect eyes from 362 healthy control (HC) eyes on a pixel-by-pixel basis.

Methods

For this retrospective study, we manually corrected the segmentations of posterior pole optical coherence tomography (OCT) scans to determine the thickness of the nerve fiber layer (NFL), ganglion cell layer (GCL), inner plexiform layer (IPL), the ganglion cell complex (GCC), and the total neural retina (TR). For each eye, the total number of pixels with thickness values less than the fifth percentile of the HC distribution was used to create a receiver operating characteristic (ROC) curve for each layer and for layer combinations.

Results

Using total abnormal pixel count criteria to discriminate glaucoma from HC eyes, the individual layers with the highest area under the ROC curve (AUC) were the NFL and GCL; IPL performance was significantly lower (P < 0.05). GCC had a significant higher AUC (94.3%) than individual the AUC of the NFL (92.3%) (P = 0.0231) but not higher than AUC of the GCL (93.4%) (P = 0.3487). The highest AUC (95.4%) and sensitivity (85.1%) at 95% specificity was found for the Boolean combination of NFL or GCL. The highest AUC is not significantly higher (P = 0.0882) than the AUC of the GCC but the highest sensitivity is significantly higher than the sensitivity of the GCC. This pattern was similar for discriminating between suspect and HC eyes (P = 0.0356).

Conclusions

Using pixel-based methods, the diagnostic accuracy of NFL and GCL exceeded that of IPL and TR. GCC had equivalent performance as NFL and GCL. The specific spatial locations within the posterior pole that exhibit best performance vary depending on which layer is being assessed. Recognizing this dependency highlights the importance of considering multiple layers independently, as they offer complementary information for effective and comprehensive diagnosis.

Subjects

MeSH terms (MEDLINE)

Tomography, Optical CoherenceRetinal Ganglion CellsNerve FibersROC CurveGlaucomaHumansRetrospective StudiesMaleFemaleMiddle AgedIntraocular PressureAgedVisual FieldsRetinaOptic Disk

Authors and institutions

  • Optic Nerve Head Research Laboratory, Devers Eye Institute, Legacy Research Institute, Portland, Oregon, United States.
  • Department of Ophthalmology and Visual Sciences, Dalhousie University, Halifax, Nova Scotia, Canada.
  • Discoveries in Sight Research Laboratories, Devers Eye Institute, Legacy Research Institute, Portland, Oregon, United States.

Funding

  • NEI NIH HHS

Cite

APA

Yang, H., Reynaud, J., Sharpe, G. P., Jennings, D., Albert, C., Holthausen, T., Jiang, X., Demirel, S., Mansberger, S. L., Nicolela, M. T., Gardiner, S. K., Chauhan, B. C., Burgoyne, C. F., & Fortune, B. (2024). Diagnostic Performance for Detection of Glaucomatous Structural Damage Using Pixelwise Analysis of Retinal Thickness Measurements. Investigative Ophthalmology & Visual Science. https://doi.org/10.1167/iovs.65.12.17

Vancouver

Yang H, Reynaud J, Sharpe GP, Jennings D, Albert C, Holthausen T, et al. Diagnostic Performance for Detection of Glaucomatous Structural Damage Using Pixelwise Analysis of Retinal Thickness Measurements. Investigative Ophthalmology & Visual Science. 2024. doi:10.1167/iovs.65.12.17

BibTeX
@article{Yang2024,
  author = {Yang, Hongli and Reynaud, Juan and Sharpe, Glen P and Jennings, Dawn and Albert, Cindy and Holthausen, Trinity and Jiang, Xiue and Demirel, Shaban and Mansberger, Steven L and Nicolela, Marcelo T and Gardiner, Stuart K and Chauhan, Balwantray C and Burgoyne, Claude F and Fortune, Brad},
  title = {Diagnostic Performance for Detection of Glaucomatous Structural Damage Using Pixelwise Analysis of Retinal Thickness Measurements},
  journal = {Investigative Ophthalmology & Visual Science},
  year = {2024},
  doi = {10.1167/iovs.65.12.17}
}
Start for free →