Journal article in Investigative Opthalmology & Visual Science, published on 2024-01-19. Written by Zhichao Wu and 7 co-authors. Institution: Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia. Major MEDLINE topics: Geographic Atrophy, Macular Degeneration. Cited 16 times so far (Crossref); 38 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

To examine the structure-function relationship in eyes with geographic atrophy (GA) using defect-mapping microperimetry, a testing strategy optimized to quantify the spatial extent of deep visual sensitivity losses.

Methods

Fifty participants with GA underwent defect-mapping microperimetry testing of the central 8°-radius region (208 locations tested once with a 10-decibel stimuli) and fundus autofluorescence imaging in one eye. The GA extent in the corresponding central 8°-radius was derived by manual annotations and image co-registration to examine the global structure-function relationship. The distance of each test location from the GA margin was also derived, and regions defined, to examine the local structure-function relationship.

Results

GA extent in the central 8° explained a substantial proportion of variance in the percentage of locations missed (nonresponse) on microperimetry at the global level (R2 = 0.90). At a local level, the probability of missing stimuli at the outer junctional zone (0-500 µm outside the GA margin) and GA margin (probability = 7% and 34%, respectively) was higher than at the outer nonlesional zone (>500 µm outside the GA margin; probability = 2%; P 250 µm inside the GA margin; probability = 64% and 88%; P < 0.001).

Conclusions

This study confirms the expected functional relevance of the region with GA on fundus autofluorescence imaging and underscores the potential effectiveness of defect-mapping microperimetry testing for capturing visual function changes when evaluating new GA treatments.

Subjects

MeSH terms (MEDLINE)

Geographic AtrophyMacular DegenerationHumansVisual Field TestsTomography, Optical CoherenceRetinal Pigment EpitheliumVision DisordersFluorescein Angiography

Authors and institutions

  • Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia.
  • Ophthalmology, Department of Surgery, The University of Melbourne, Melbourne, Australia.

Cite

APA

Wu, Z., Hadoux, X., Jannaud, M., Glover, E. K., Gee, E. E., Hodgson, L. A. B., van Wijngaarden, P., & Guymer, R. H. (2024). Visual Sensitivity Loss in Geographic Atrophy: Structure–Function Evaluation Using Defect-Mapping Microperimetry. Investigative Opthalmology & Visual Science, 65(1), 36. https://doi.org/10.1167/iovs.65.1.36

Vancouver

Wu Z, Hadoux X, Jannaud M, Glover EK, Gee EE, Hodgson LAB, et al. Visual Sensitivity Loss in Geographic Atrophy: Structure–Function Evaluation Using Defect-Mapping Microperimetry. Investigative Opthalmology & Visual Science. 2024;65(1):36. doi:10.1167/iovs.65.1.36

BibTeX
@article{Wu2024,
  author = {Wu, Zhichao and Hadoux, Xavier and Jannaud, Maxime and Glover, Emily K and Gee, Erin E and Hodgson, Lauren A B and van Wijngaarden, Peter and Guymer, Robyn H},
  title = {Visual Sensitivity Loss in Geographic Atrophy: Structure–Function Evaluation Using Defect-Mapping Microperimetry},
  journal = {Investigative Opthalmology & Visual Science},
  year = {2024},
  volume = {65},
  number = {1},
  pages = {36},
  doi = {10.1167/iovs.65.1.36}
}
Start for free →