Fachartikel in der Zeitschrift Investigative Opthalmology & Visual Science, erschienen am 19.01.2024. Verfasst von Zhichao Wu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia. Hauptthemen laut MEDLINE: Geographic Atrophy, Macular Degeneration. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To examine the structure-function relationship in eyes with geographic atrophy (GA) using defect-mapping microperimetry, a testing strategy optimized to quantify the spatial extent of deep visual sensitivity losses.

Methods

Fifty participants with GA underwent defect-mapping microperimetry testing of the central 8°-radius region (208 locations tested once with a 10-decibel stimuli) and fundus autofluorescence imaging in one eye. The GA extent in the corresponding central 8°-radius was derived by manual annotations and image co-registration to examine the global structure-function relationship. The distance of each test location from the GA margin was also derived, and regions defined, to examine the local structure-function relationship.

Results

GA extent in the central 8° explained a substantial proportion of variance in the percentage of locations missed (nonresponse) on microperimetry at the global level (R2 = 0.90). At a local level, the probability of missing stimuli at the outer junctional zone (0-500 µm outside the GA margin) and GA margin (probability = 7% and 34%, respectively) was higher than at the outer nonlesional zone (>500 µm outside the GA margin; probability = 2%; P 250 µm inside the GA margin; probability = 64% and 88%; P < 0.001).

Conclusions

This study confirms the expected functional relevance of the region with GA on fundus autofluorescence imaging and underscores the potential effectiveness of defect-mapping microperimetry testing for capturing visual function changes when evaluating new GA treatments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Geographic AtrophyMacular DegenerationHumansVisual Field TestsTomography, Optical CoherenceRetinal Pigment EpitheliumVision DisordersFluorescein Angiography

Autor:innen und Institutionen

  • Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Australia.
  • Ophthalmology, Department of Surgery, The University of Melbourne, Melbourne, Australia.

Zitieren

APA

Wu, Z., Hadoux, X., Jannaud, M., Glover, E. K., Gee, E. E., Hodgson, L. A. B., van Wijngaarden, P., & Guymer, R. H. (2024). Visual Sensitivity Loss in Geographic Atrophy: Structure–Function Evaluation Using Defect-Mapping Microperimetry. Investigative Opthalmology & Visual Science, 65(1), 36. https://doi.org/10.1167/iovs.65.1.36

Vancouver

Wu Z, Hadoux X, Jannaud M, Glover EK, Gee EE, Hodgson LAB, et al. Visual Sensitivity Loss in Geographic Atrophy: Structure–Function Evaluation Using Defect-Mapping Microperimetry. Investigative Opthalmology & Visual Science. 2024;65(1):36. doi:10.1167/iovs.65.1.36

BibTeX
@article{Wu2024,
  author = {Wu, Zhichao and Hadoux, Xavier and Jannaud, Maxime and Glover, Emily K and Gee, Erin E and Hodgson, Lauren A B and van Wijngaarden, Peter and Guymer, Robyn H},
  title = {Visual Sensitivity Loss in Geographic Atrophy: Structure–Function Evaluation Using Defect-Mapping Microperimetry},
  journal = {Investigative Opthalmology & Visual Science},
  year = {2024},
  volume = {65},
  number = {1},
  pages = {36},
  doi = {10.1167/iovs.65.1.36}
}
Kostenlos starten →