EUVIMEDОткрийте EUVIMED
Open access · CC BY-NC-ND 4.0

Rapid Alternate Flicker Modulates Binocular Interaction in Adults With Abnormal Binocular Vision

Yiqiu Lu, Liying Zou, Yiya Chen, Yu Mao, Jinli Zhu, Wenman Lin, Dingqiang Wu, Ruyin Chen, Jia Qu, Jiawei Zhou

Investigative Opthalmology & Visual Science · 2023

DOI: 10.1167/iovs.64.2.15 ↗

At a glance

Journal article in Investigative Opthalmology & Visual Science, 2023. Written by Yiqiu Lu and 9 co-authors. Institution: State Key Laboratory of Ophthalmology, Optometry and Visual Science and National Engineering Research Center of Ophthalmology and Optometry, Eye Hosp…. Major MEDLINE topics: Vision, Binocular, Amblyopia. Cited 5 times so far (Crossref); 45 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

РезюмеSubjectsБиблиографски данниCiteRelated studies

Abstract (original language)

Purpose

The current understanding of binocular processing is primarily derived from static spatial visual perception: this leaves the role of temporal information unclear. In this study, we addressed this gap by testing the effect of alternating flicker on binocular information processing in adults with abnormal binocular vision. Our goal was to determine which temporal frequency optimally balanced input from both eyes.

Methods

We took measurements in four groups of human adults: 10 normal adults with the individual's nondominant eye covered by a 2% neutral density filter (aged 25.60 ± 1.43 years, experiment 1), 9 nonamblyopic anisometropes (aged 24.33 ± 1.66 years, experiment 2), 7 amblyopes (aged 26.5 ± 1.64 years, experiment 3), and 7 treated amblyopes (aged 24 ± 3.21 years, experiment 4). The balance point (BP), where participants' two eyes are equally effective, was measured using a binocular orientation combination task at four spatial frequencies (SFs; 0.5-4 c/d) and five temporal frequencies (TFs; baseline and 4, 7, 10, and 15 Hz). Its log transformation |logBP| was taken into further analysis.

Results

We observed clear U-shaped temporal tuning of the |logBP| for the entire range of TFs (that we measured: trough occurred at 7 Hz). This pattern occurred and was significant in all four groups (P < 0.001). In addition, the effect of SFs on |logBP| was significant in normal, amblyopic, and treated amblyopic groups (all P < 0.001) and was marginally significant in the nonamblyopic anisometropic group (P = 0.086).

Conclusions

Alternating flicker around 7 Hz may be the optimal temporal frequency for balancing eyes in human adults with binocular imbalance.

Subjects

MeSH terms (MEDLINE)

Vision, BinocularAmblyopiaHumansAdultVisual PerceptionVision, Ocular

Authors and institutions

  • State Key Laboratory of Ophthalmology, Optometry and Visual Science and National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital Wenzhou Medical University, Wenzhou, China.
  • Oujiang Laboratory, Zhejiang Lab for Regenerative Medicine, Vision and Brain Health, Wenzhou, China.

Cite

APA

Lu, Y., Zou, L., Chen, Y., Mao, Y., Zhu, J., Lin, W., Wu, D., Chen, R., Qu, J., & Zhou, J. (2023). Rapid Alternate Flicker Modulates Binocular Interaction in Adults With Abnormal Binocular Vision. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.64.2.15

Vancouver

Lu Y, Zou L, Chen Y, Mao Y, Zhu J, Lin W, et al. Rapid Alternate Flicker Modulates Binocular Interaction in Adults With Abnormal Binocular Vision. Investigative Opthalmology & Visual Science. 2023. doi:10.1167/iovs.64.2.15

BibTeX
@article{Lu2023,
  author = {Lu, Yiqiu and Zou, Liying and Chen, Yiya and Mao, Yu and Zhu, Jinli and Lin, Wenman and Wu, Dingqiang and Chen, Ruyin and Qu, Jia and Zhou, Jiawei},
  title = {Rapid Alternate Flicker Modulates Binocular Interaction in Adults With Abnormal Binocular Vision},
  journal = {Investigative Opthalmology & Visual Science},
  year = {2023},
  doi = {10.1167/iovs.64.2.15}
}
Start for free →