EUVIMEDOpdag EUVIMED
Open access · CC BY-NC-ND 4.0

Enhanced S-Cone Syndrome: Elevated Cone Counts Confer Supernormal Visual Acuity in the S-Cone Pathway

Yiyi Wang, Jessica Wong, Jacque L Duncan, Austin Roorda, William S Tuten

Investigative Opthalmology & Visual Science · 2023

DOI: 10.1167/iovs.64.10.17 ↗

At a glance

Journal article in Investigative Opthalmology & Visual Science, 2023. Written by Yiyi Wang and 4 co-authors. Institution: Herbert Wertheim School of Optometry and Vision Science, University of California, Berkeley, California, United States. Major MEDLINE topics: Retinal Degeneration, Retinal Cone Photoreceptor Cells. Cited 7 times so far (Crossref); 85 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: NEI NIH HHS.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Purpose

To measure photoreceptor packing density and S-cone spatial resolution as a function of retinal eccentricity in patients with enhanced S-cone syndrome (ESCS) and to discuss the possible mechanisms supporting their supernormal S-cone acuity.

Methods

We used an adaptive optics scanning laser ophthalmoscope (AOSLO) to characterize photoreceptor packing. A custom non-AO display channel was used to measure L/M- and S-cone-mediated visual acuity during AOSLO imaging. Acuity measurements were obtained using a four-alternative, forced-choice, tumbling E paradigm along the temporal meridian between the fovea and 4° eccentricity in five of six patients and in seven control subjects. L/M acuity was tested by presenting long-pass-filtered optotypes on a black background, excluding wavelengths to which S-cones are sensitive. S-cone isolation was achieved using a two-color, blue-on-yellow chromatic adaptation method that was validated on three control subjects.

Results

Inter-cone spacing measurements revealed a near-uniform cone density profile (ranging from 0.9-1.5 arcmin spacing) throughout the macula in ESCS. For comparison, normal cone density decreases by a factor of 14 from the fovea to 6°. Cone spacing of ESCS subjects was higher than normal in the fovea and subnormal beyond 2°. Compared to the control subjects (n = 7), S-cone-mediated acuities in patients with ESCS were normal near the fovea and became increasingly supernormal with retinal eccentricity. Beyond 2°, S-cone acuities were superior to L/M-cone-mediated acuity in the ESCS cohort, a reversal of the trend observed in normal retinas.

Conclusions

Higher than normal parafoveal cone densities (presumably dominated by S-cones) confer better than normal S-cone-mediated acuity in ESCS subjects.

Subjects

MeSH terms (MEDLINE)

Retinal DegenerationRetinal Cone Photoreceptor CellsRetinaFovea CentralisHumansVisual AcuityVision DisordersEye Diseases, HereditaryOphthalmoscopy

Authors and institutions

  • Herbert Wertheim School of Optometry and Vision Science, University of California, Berkeley, California, United States.
  • Department of Ophthalmology, University of California, San Francisco, California, United States.

Funding

  • NEI NIH HHS

Cite

APA

Wang, Y., Wong, J., Duncan, J. L., Roorda, A., & Tuten, W. S. (2023). Enhanced S-Cone Syndrome: Elevated Cone Counts Confer Supernormal Visual Acuity in the S-Cone Pathway. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.64.10.17

Vancouver

Wang Y, Wong J, Duncan JL, Roorda A, Tuten WS. Enhanced S-Cone Syndrome: Elevated Cone Counts Confer Supernormal Visual Acuity in the S-Cone Pathway. Investigative Opthalmology & Visual Science. 2023. doi:10.1167/iovs.64.10.17

BibTeX
@article{Wang2023,
  author = {Wang, Yiyi and Wong, Jessica and Duncan, Jacque L and Roorda, Austin and Tuten, William S},
  title = {Enhanced S-Cone Syndrome: Elevated Cone Counts Confer Supernormal Visual Acuity in the S-Cone Pathway},
  journal = {Investigative Opthalmology & Visual Science},
  year = {2023},
  doi = {10.1167/iovs.64.10.17}
}
Start for free →