Fallbericht in der Zeitschrift Biochemia medica, 2023. Verfasst von Nadia Sadriani und 1 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Pathology Specialist Programme, Department of Medicine, Dr Soetomo Academic Hospital/Faculty of Medicine Universitas Airlangga, Surabaya, In…. Hauptthemen laut MEDLINE: Hemoglobin E, Diabetes Mellitus, Diabetes Mellitus, Type 2. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
The gold standard for long-term monitoring of diabetic patients is glycated haemoglobin (HbA1c), which is routinely tested for glycaemic control. Furthermore, the National glycohemoglobin standardization program (NGSP) has designated high-performance liquid chromatography (HPLC) as the reference method for HbA1c measurement. A woman from the Sumba tribe, Indonesia, aged 52, visited the Internal Medicine Clinic for a routine check-up. She had been taking diabetic and hypertension medicines on a regular basis for over 10 years. The HPLC procedure yielded “no result” for the patient’s HbA1c assessment and there was no peak on the HPLC graphic. However, there was a discrepancy between the data history of HbA1c measured by turbidimetric method (average of 51 mmol/mol, reference range < 48 mmol/mol), fasting blood glucose (average of 7.7 mmol/L, reference range < 7.0 mmol/L) and 2-hour plasma glucose (average of 13 mmol/L, reference range < 11.1 mmol/L). Glycated albumin was 3.1 mmol/L (reference range 1.8-2.4 mmol/L). Haemoglobin electrophoresis identified homozygote haemoglobinopathy E (HbE). Patients with haemoglobin variants are proposed to utilize glycated albumin.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Clinical Pathology Specialist Programme, Department of Medicine, Dr Soetomo Academic Hospital/Faculty of Medicine Universitas Airlangga, Surabaya, Indonesia.
- Department of Clinical Pathology, Dr Soetomo Academic Hospital/Faculty of Medicine, Universitas Airlangga, Surabaya, Indonesia.
Zitieren
APA
Sadriani, N., & Marpaung, F. R. (2023). Undetectable high-performance liquid chromatography haemoglobin A1c on variant haemoglobin E phenotype. Biochemia medica. https://doi.org/10.11613/bm.2023.030801
Vancouver
Sadriani N, Marpaung FR. Undetectable high-performance liquid chromatography haemoglobin A1c on variant haemoglobin E phenotype. Biochemia medica. 2023. doi:10.11613/bm.2023.030801
BibTeX
@article{Sadriani2023,
author = {Sadriani, Nadia and Marpaung, Ferdy Royland},
title = {Undetectable high-performance liquid chromatography haemoglobin A1c on variant haemoglobin E phenotype},
journal = {Biochemia medica},
year = {2023},
doi = {10.11613/bm.2023.030801}
}
EUVIMED