Uncommon causes of hemoglobin E flags identified during measurement of hemoglobin A1c by ion-exchange high-performance liquid chromatography
Laboratory Medicine · 2024
DOI: 10.1093/labmed/lmad113 ↗Kurz gefasst
Fallbericht in der Zeitschrift Laboratory Medicine, 2024. Verfasst von Thomas Herb und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pathology, University of Michigan, Ann Arbor, MI, US. Hauptthemen laut MEDLINE: Glycated Hemoglobin, Hemoglobin E. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben.
Abstract (Originalsprache)
We present 3 cases of discordant results from screening hemoglobin A1c (HbA1c) measured by ion-exchange high-performance liquid chromatography (HPLC) all due to various forms of interference and flagged by the instrument as “suspected hemoglobin E (HbE).” The first case was due to a rare hemoglobin variant, later confirmed to be hemoglobin Hoshida, the second due to “true” heterozygous HbE, and the third a result of analytical artifact causing splitting of the HbA1c peak without an underlying variant hemoglobin. We examine the similarities in these cases along with the laboratory work-up to classify each cause of interference to demonstrate the wide array of potential causes for the suspected HbE flag and why it warrants proper work-up. Because there is no standardized method of reporting out hemoglobin variant interference in HbA1c measurement, we discuss our laboratory’s process of investigating discordant HbA1c measurements and reporting results in cases with variant interference as 1 possible model to follow, along with discussing the associated laboratory, ethical, and clinical considerations. We also examine the structure of hemoglobin Hoshida, HbE, and conduct a brief literature review of previous reports.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Pathology, University of Michigan, Ann Arbor, MI, US.
ORCID-Profile: Thomas Herb, Shih-Hon Li
Zitieren
APA
Herb, T., Taylor, A. S., Li, S. H., Manthei, D. M., & Gherasim, C. (2024). Uncommon causes of hemoglobin E flags identified during measurement of hemoglobin A1c by ion-exchange high-performance liquid chromatography. Laboratory Medicine. https://doi.org/10.1093/labmed/lmad113
Vancouver
Herb T, Taylor AS, Li SH, Manthei DM, Gherasim C. Uncommon causes of hemoglobin E flags identified during measurement of hemoglobin A1c by ion-exchange high-performance liquid chromatography. Laboratory Medicine. 2024. doi:10.1093/labmed/lmad113
BibTeX
@article{Herb2024,
author = {Herb, Thomas and Taylor, Alexander S and Li, Shih-Hon and Manthei, David M and Gherasim, Carmen},
title = {Uncommon causes of hemoglobin E flags identified during measurement of hemoglobin A1c by ion-exchange high-performance liquid chromatography},
journal = {Laboratory Medicine},
year = {2024},
doi = {10.1093/labmed/lmad113}
}
EUVIMED