Underfilled blood tube containing EDTA

Berrak Guven, Ismail Benice, Murat Can

Biochemia medica · 2023

DOI: 10.11613/bm.2023.010901 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biochemia medica, 2023. Verfasst von Berrak Guven und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biochemistry, Faculty of Medicine, Zonguldak Bülent Ecevit University, Zonguldak, Turkey. Hauptthemen laut MEDLINE: Blood Specimen Collection, Diabetes Mellitus. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

IntroductionBlood samples having inappropriate volume are a substantial part of preanalytical errors. Inadequate sample volume for glycated haemoglobin (HbA1c) test may be a common problem of patients with diabetes mellitus having vascular changes. In this study, we compared HbA1c concentrations of underfilled and appropriately filled blood collection tubes. Materials and methodsTo compare HbA1c concentrations, blood samples were collected into 2 mL tubes containing K3-EDTA from 109 subjects. Two blood samples (underfilled and appropriately filled) were drawn from a patient by the same personnel and materials. HbA1c measurements were assayed on a Cobas 6000 analyser module c 501 (Roche Diagnostics, Mannheim, Germany). The HbA1c% results were compared by t-test and Wilcoxon’s signed-rank statistical methods (SPSS Inc., Chicago, USA). Bias analysis was performed using Microsoft Excel 4.0. ResultsUnderfilled samples were classified three groups (group 1, N = 44; group 2, N = 36; and group 3, N = 29) according to the filling ratio of the samples; 0.5 mL and below (< 25%), 0.5-1.0 mL (25-50%), and 1.0-2.0 mL (> 50%), respectively. When we compared underfilled tubes with pairing filled tubes, there was a statistically significant difference only with tubes filled less than 25% (P = 0.030). Furthermore, we have done bias analysis between paired tubes according to the diagnostic cut-off value of 6.5%. The bias was more prominent in up to 50% underfilled blood tubes (1.1%), when HbA1c concentrations were below the diagnostic cut-off of 6.5%. ConclusionsWe suggest that the blood tubes with EDTA for HbA1c measurement should be filled with at least 50% to avoid clinical variations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood Specimen CollectionDiabetes MellitusHumansEdetic AcidGlycated HemoglobinBiological Assay

Stichwörter der Autor:innen

HbA1cblood sample collectiondiabetes mellituspreanalytical error

Substanzen

Edetic AcidGlycated Hemoglobin

Autor:innen und Institutionen

  • Department of Biochemistry, Faculty of Medicine, Zonguldak Bülent Ecevit University, Zonguldak, Turkey.

Zitieren

APA

Guven, B., Benice, I., & Can, M. (2023). Underfilled blood tube containing EDTA. Biochemia medica. https://doi.org/10.11613/bm.2023.010901

Vancouver

Guven B, Benice I, Can M. Underfilled blood tube containing EDTA. Biochemia medica. 2023. doi:10.11613/bm.2023.010901

BibTeX
@article{Guven2023,
  author = {Guven, Berrak and Benice, Ismail and Can, Murat},
  title = {Underfilled blood tube containing EDTA},
  journal = {Biochemia medica},
  year = {2023},
  doi = {10.11613/bm.2023.010901}
}
Kostenlos starten →