Time‐Dependent EDTA Effect on Leukocyte Differential Count and Morphology Compared to Blood Smear Made by Direct Finger Prick
International Journal of Laboratory Hematology · 2025
DOI: 10.1111/ijlh.14498 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift International Journal of Laboratory Hematology, 2025. Verfasst von Anna Irding und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Chemistry, Linköping University, Linköping, Sweden. Hauptthemen laut MEDLINE: Edetic Acid, Leukocytes, Blood Specimen Collection. Die Arbeit nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
The impact of ethylenediaminetetraacetic acid (EDTA) on leukocyte count and morphology has led to the current recommendation that smears made from EDTA blood should be prepared within 4 h of sampling. However, previous studies have only been performed on smears with normal cell counts, and smears made from K 2 EDTA blood have not been studied in comparison with smears made from direct finger prick. The aim of this study was to investigate the time limit for performing a morphological assessment on smears from EDTA blood without compromising the results.
Methods
Blood samples from 37 patients with known or suspected abnormal leukocyte morphology were selected, with smears from direct finger prick used as controls. Smears were prepared from the original EDTA tube every 4 h up to 24 h after sampling. The smears were evaluated for differential count, morphological assessment, and smear quality scoring.
Results
No significant difference in cell count was observed on smears made up to 12 h after sampling for neutrophils ( p = 0.430), lymphocytes ( p = 0.080), monocytes ( p = 0.948) eosinophils ( p = 0.398), basophils ( p = 0.460), and blast cells ( p = 0.239) compared to smears made by finger prick. However, smears prepared later than 8 h postsampling showed a significant increase in morphological changes.
Conclusion
A manual differential leukocyte count can be reliably performed on smears from EDTA blood within 12 h, whereas a comprehensive morphological assessment requires smears to be prepared within 8 h of sampling.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Clinical Chemistry, Linköping University, Linköping, Sweden.
- Department of Biomedical and Clinical Sciences, Linköping University, Linköping, Sweden.
ORCID-Profile: Anna Irding
Zitieren
APA
Irding, A., Landgren, F., & Aardal, E. (2025). Time‐Dependent EDTA Effect on Leukocyte Differential Count and Morphology Compared to Blood Smear Made by Direct Finger Prick. International Journal of Laboratory Hematology. https://doi.org/10.1111/ijlh.14498
Vancouver
Irding A, Landgren F, Aardal E. Time‐Dependent EDTA Effect on Leukocyte Differential Count and Morphology Compared to Blood Smear Made by Direct Finger Prick. International Journal of Laboratory Hematology. 2025. doi:10.1111/ijlh.14498
BibTeX
@article{Irding2025,
author = {Irding, Anna and Landgren, Filip and Aardal, Elisabeth},
title = {Time‐Dependent EDTA Effect on Leukocyte Differential Count and Morphology Compared to Blood Smear Made by Direct Finger Prick},
journal = {International Journal of Laboratory Hematology},
year = {2025},
doi = {10.1111/ijlh.14498}
}
EUVIMED