EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Efficacy and Safety of Stent-Assisted Coiling Versus Coiling Alone for Ruptured Multilobed Aneurysms: A Multicenter Study

ZhenKun Xiao iD, ShanShan Mi, Wang Bing, YongHong Duan, AiHua Liu iD

Stroke: Vascular and Interventional Neurology · 2026-11 · 6 (6)

DOI: 10.1161/svin.126.002556 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Stroke: Vascular and Interventional Neurology, 2026-11. Verfasst von ZhenKun Xiao und 4 weiteren Autor:innen. Beteiligte Einrichtung: Hengyang Key Laboratory of Hemorrhagic Cerebrovascular Disease, Department of Neurosurgery, the Second Affiliated Hospital, Hengyang Medical School, …. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Ruptured multilobed intracranial aneurysms present significant procedural challenges and high recurrence risks in endovascular treatment due to complex geometry and turbulent hemodynamics. Currently, the safety and long-term efficacy of stent-assisted coiling (SAC) versus coiling alone in treating this high-risk morphological subgroup remain clinically controversial; high-quality, large-scale evidence is required. METHODS: Based on a multicenter, prospective registry study (the SANE trial [Subarachnoid Aneurysm Endovascular Cohort Study in China]), 627 consecutive patients with ruptured multilobed intracranial aneurysm treated with SAC or coiling alone were included. Baseline demographics, perioperative safety outcomes (including intraprocedural thrombosis, ischemic stroke, cerebral vasospasm, and rerupture), clinical functional outcomes (modified Rankin Scale score and mortality), and angiographic morphological outcomes (Raymond-Roy Occlusion Classification) were systematically collected. Overlap weighting (average treatment effect in the overlap population) and doubly robust logistic regression models were applied to evaluate the independent clinical effects of different modalities after strict adjustment for confounders, including anatomic morphology and perioperative parameters. RESULTS: The cohort comprised 173 patients treated with coiling alone and 454 treated with SAC. The primary average treatment effect in the overlap population analysis included 610 patients and yielded a pooled Kish effective sample size of 438.74. Before weighting, perioperative ischemic stroke and intraprocedural thrombosis were more frequent with SAC. After weighting, all 16 prespecified covariates had absolute standardized mean differences

Schlagwörter

Stichwörter der Autor:innen

hemodynamicsintracranial aneurysmsischemic strokestentssubarachnoid hemorrhage

Autor:innen und Institutionen

  • Hengyang Key Laboratory of Hemorrhagic Cerebrovascular Disease, Department of Neurosurgery, the Second Affiliated Hospital, Hengyang Medical School, University of South China, Hunan (Z.X., S.M., W.B., Y.D., A.L.).
  • Beijing Neurosurgical Institute, Capital Medical University, China (A.L.).
  • Department of Interventional Neuroradiology, Beijing Tiantan Hospital, China (A.L.).

ORCID-Profile: ZhenKun Xiao, AiHua Liu

Zitieren

APA

Xiao, Z., Mi, S., Bing, W., Duan, Y., & Liu, A. (2026). Efficacy and Safety of Stent-Assisted Coiling Versus Coiling Alone for Ruptured Multilobed Aneurysms: A Multicenter Study. Stroke: Vascular and Interventional Neurology, 6(6). https://doi.org/10.1161/svin.126.002556

Vancouver

Xiao Z, Mi S, Bing W, Duan Y, Liu A. Efficacy and Safety of Stent-Assisted Coiling Versus Coiling Alone for Ruptured Multilobed Aneurysms: A Multicenter Study. Stroke: Vascular and Interventional Neurology. 2026;6(6). doi:10.1161/svin.126.002556

BibTeX
@article{Xiao2026,
  author = {Xiao, ZhenKun and Mi, ShanShan and Bing, Wang and Duan, YongHong and Liu, AiHua},
  title = {Efficacy and Safety of Stent-Assisted Coiling Versus Coiling Alone for Ruptured Multilobed Aneurysms: A Multicenter Study},
  journal = {Stroke: Vascular and Interventional Neurology},
  year = {2026},
  volume = {6},
  number = {6},
  doi = {10.1161/svin.126.002556}
}
Kostenlos starten →