Safety and Efficacy of LVIS Jr Stent-assisted Coiling of Intracranial Aneurysms in Small-diameter Parent Arteries
Clinical Neuroradiology · 2024-09 · 34 (3) · 587-595
DOI: 10.1007/s00062-024-01397-0 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Neuroradiology, online erschienen am 07.03.2024. Verfasst von Shuailong Shi und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Jianshe Road No. 1, Er qi district, Zhengzhou, Henan, …. Hauptthemen laut MEDLINE: Intracranial Aneurysm, Stents, Angiography, Digital Subtraction, Embolization, Therapeutic. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: National Outstanding Youth Science Fund Project of National Natural Science Foundation of China, Henan Provincial Science and Technology Research Project.
Abstract (Originalsprache)
OBJECTIVE: To investigate the safety and efficacy of LVIS Jr stent-assisted coiling (SAC) of intracranial aneurysms (IAs) in small-diameter parent arteries and determine the factors influencing incomplete aneurysm occlusion. MATERIAL AND METHODS: Clinical and imaging data of 130 patients with IAs in small-diameter parent arteries that were treated with LVIS Jr SAC were retrospectively analyzed. Stent apposition was evaluated by high-resolution flat detector CT, and aneurysm embolization density was evaluated using 2D-DSA. Perioperative complications were recorded. Multivariate logistic regression analyses were performed to determine possible factors for incomplete aneurysm occlusion. RESULTS: In this study, 130 patients (60 and 70 patients with ruptured and unruptured aneurysms, respectively) were successfully treated with LVIS Jr SAC. Immediate digital subtraction angiography (DSA) showed that the aneurysm occlusion was Raymond-Roy class I, II, IIIa, and IIIb in 93 (71.5%), 24 (18.5%), 8 (6.2%), and 5 (3.8%) cases, respectively. There were three cases of acute in-stent thrombosis and two cases of severe vasospasm observed during the perioperative period. The 6‑month follow-up angiograms indicated that complete aneurysm occlusion in 122 patients was 79.5% (97/122). Multivariate logistic regression analyses showed that an aneurysm size > 10.0 mm, parent artery mean diameter 10.0 mm, parent artery mean diameter < 2.0 mm, and incomplete stent apposition at the aneurysm neck are possible risk factors for incomplete aneurysm occlusion.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Jianshe Road No. 1, Er qi district, Zhengzhou, Henan, China.
- Interventional Institute of Zhengzhou University, Zhengzhou, China.
- Xi'an Jiaotong University, Xi'an, China.
- Department of Interventional Radiology, The First Affiliated Hospital of Zhengzhou University, Jianshe Road No. 1, Er qi district, Zhengzhou, Henan, China. 50632953@qq.com.
- Interventional Institute of Zhengzhou University, Zhengzhou, China. 50632953@qq.com.
Förderung
- National Outstanding Youth Science Fund Project of National Natural Science Foundation of China
- Henan Provincial Science and Technology Research Project
Zitieren
APA
Shi, S., Long, S., Hui, F., Tian, Q., Wei, Z., Ma, J., Yang, J., Wang, Y., Han, X., & Li, T. (2024). Safety and Efficacy of LVIS Jr Stent-assisted Coiling of Intracranial Aneurysms in Small-diameter Parent Arteries. Clinical Neuroradiology, 34(3), 587-595. https://doi.org/10.1007/s00062-024-01397-0
Vancouver
Shi S, Long S, Hui F, Tian Q, Wei Z, Ma J, et al. Safety and Efficacy of LVIS Jr Stent-assisted Coiling of Intracranial Aneurysms in Small-diameter Parent Arteries. Clinical Neuroradiology. 2024;34(3):587-595. doi:10.1007/s00062-024-01397-0
BibTeX
@article{Shi2024,
author = {Shi, Shuailong and Long, Shuhai and Hui, Fangfang and Tian, Qi and Wei, Zhuangzhuang and Ma, Ji and Yang, Jie and Wang, Ye and Han, Xinwei and Li, Tengfei},
title = {Safety and Efficacy of LVIS Jr Stent-assisted Coiling of Intracranial Aneurysms in Small-diameter Parent Arteries},
journal = {Clinical Neuroradiology},
year = {2024},
volume = {34},
number = {3},
pages = {587--595},
doi = {10.1007/s00062-024-01397-0}
}