EUVIMEDEUVIMED entdecken
Open Access

Shear Difference: Flow Type Dictates Endothelial Flow‐Responsive Gene Programs in a 3‐Dimensional–Printed In Vitro Model

Nasir A Shah iD, Kerry-Anne Rye iD, Zoltan H Endre iD, Tracie J Barber iD, Jonathan H Erlich iD, Blake J Cochran iD

Journal of the American Heart Association · 21.07.2026 · 15 (14)

DOI: 10.1161/jaha.125.049901 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the American Heart Association, erschienen am 21.07.2026. Verfasst von Nasir A Shah und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Clinical Medicine, Faculty of Medicine and Health University of New South Wales Sydney NSW Australia. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Endothelial Cells, Mechanotransduction, Cellular. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Endothelial cells are mechanosensitive and adopt distinct phenotypes in response to hemodynamic forces. These responses are difficult to study in conventional in vitro platforms, which rarely reproduce vessel‐scale geometry or clinically relevant flow. Our aim was to determine how flow impacts endothelial morphology and transcriptional activity in a 3‐dimensional macrofluidic model.

Methods

Idealized vessels were 3‐dimensional printed using a water‐soluble polyvinyl alcohol and cast in polydimethylsiloxane. After core dissolution, human microvascular endothelial cell line‐1 cells were grown on the lumen and perfused for 24 hours under static, continuous, or pulsatile flow. The pulsatile waveform was derived from arteriovenous fistula Doppler profiles and scaled to match mean volumetric flow (~100 mL/min) and time‐averaged wall shear stress (~1.5 dyn/cm 2 ) to continuous flow. Morphology was assessed using immunofluorescence. Bulk RNA‐sequencing and gene set enrichment analysis were performed.

Results

Relative to static culture, continuous flow increased cell eccentricity (0.74 versus 0.48; P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalEndothelial CellsMechanotransduction, CellularHumansPulsatile FlowStress, MechanicalCell LineGene Expression Regulation

Stichwörter der Autor:innen

3‐dimensional macrofluidicsRNA sequencingendothelial mechanotransductionwall shear stress

Autor:innen und Institutionen

  • School of Clinical Medicine, Faculty of Medicine and Health University of New South Wales Sydney NSW Australia.
  • Department of Nephrology Prince of Wales Hospital Sydney NSW Australia.
  • School of Biomedical Sciences, Faculty of Medicine and Health University of New South Wales Sydney NSW Australia.
  • School of Mechanical and Manufacturing Engineering, Faculty of Engineering University of New South Wales Sydney NSW Australia.

ORCID-Profile: Nasir A Shah, Kerry-Anne Rye, Zoltan H Endre, Tracie J Barber, Jonathan H Erlich, Blake J Cochran

Zitieren

APA

Shah, N. A., Rye, K. A., Endre, Z. H., Barber, T. J., Erlich, J. H., & Cochran, B. J. (2026). Shear Difference: Flow Type Dictates Endothelial Flow‐Responsive Gene Programs in a 3‐Dimensional–Printed In Vitro Model. Journal of the American Heart Association, 15(14). https://doi.org/10.1161/jaha.125.049901

Vancouver

Shah NA, Rye KA, Endre ZH, Barber TJ, Erlich JH, Cochran BJ. Shear Difference: Flow Type Dictates Endothelial Flow‐Responsive Gene Programs in a 3‐Dimensional–Printed In Vitro Model. Journal of the American Heart Association. 2026;15(14). doi:10.1161/jaha.125.049901

BibTeX
@article{Shah2026,
  author = {Shah, Nasir A and Rye, Kerry-Anne and Endre, Zoltan H and Barber, Tracie J and Erlich, Jonathan H and Cochran, Blake J},
  title = {Shear Difference: Flow Type Dictates Endothelial Flow‐Responsive Gene Programs in a 3‐Dimensional–Printed In Vitro Model},
  journal = {Journal of the American Heart Association},
  year = {2026},
  volume = {15},
  number = {14},
  doi = {10.1161/jaha.125.049901}
}
Kostenlos starten →