EUVIMEDEUVIMED entdecken
Vergleichsstudie

Left Ventricular Unloading With Impella Versus Intra‐Aortic Balloon Pump in Cardiogenic Shock Requiring Venoarterial Extracorporeal Membrane Oxygenation

Ryota Ito, Toru Kondo iD, Shingo Kazama iD, Takashi Araki, Takahiro Imaizumi, Takeru Nabeta iD, Yuki Ikeda iD, Hiroki Matsuzoe, Koichiro Matsumura iD, Koshiro Kanaoka iD, Toshiyuki Nagai iD, Takeo Fujino iD und 2 weitere

Journal of the American Heart Association · 2026

DOI: 10.1161/jaha.125.047993 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of the American Heart Association, 2026. Verfasst von Ryota Ito und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology Nagoya University Graduate School of Medicine Nagoya Japan. Hauptthemen laut MEDLINE: Shock, Cardiogenic, Intra-Aortic Balloon Pumping, Heart-Assist Devices, Extracorporeal Membrane Oxygenation. Die Arbeit nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Optimal unloading strategies for patients with cardiogenic shock requiring venoarterial extracorporeal membrane oxygenation remain uncertain, particularly when comparing Impella and intra‐aortic balloon pump (IABP). We aimed to compare outcomes of patients receiving Impella or IABP during venoarterial extracorporeal membrane oxygenation and evaluate cause‐specific differences.

Methods

In this retrospective cohort study using the nationwide JROAD‐DPC (Japanese Registry of All Cardiac and Vascular Diseases–Diagnosis Procedure Combination) database from 2012 to 2023, patients with cardiogenic shock treated with venoarterial extracorporeal membrane oxygenation and either Impella or IABP were analyzed. Propensity score–based inverse probability of treatment weighting was applied to adjust baseline differences.

Results

Among 18 906 patients (Impella, n=1688; IABP, n=17 218), overall in‐hospital mortality was 57.3% with Impella and 67.2% with IABP. Impella use was associated with lower in‐hospital mortality compared with IABP (odds ratio [OR], 0.86 [95% CI, 0.75–0.99]). Cause‐specific analyses showed significantly lower mortality with Impella in heart failure (OR, 0.66 [95% CI, 0.47–0.91]) and arrhythmia (OR, 0.62 [95% CI, 0.42–0.91]). Impella use was also associated with longer hospital stay (median, 22 versus 12 days), longer support duration (7 versus 4 days), and higher total costs (56.1 versus 27.3 thousand USD).

Conclusions

In this nationwide cohort, Impella unloading during venoarterial extracorporeal membrane oxygenation was associated with lower in‐hospital mortality than IABP in the overall cohort, particularly in selected causes, at the expense of prolonged hospitalization and higher costs. Further studies are needed to define optimal cause‐specific unloading strategies in cardiogenic shock.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Shock, CardiogenicIntra-Aortic Balloon PumpingHeart-Assist DevicesExtracorporeal Membrane OxygenationVentricular Function, LeftHumansRetrospective StudiesHospital MortalityFemaleMaleAgedMiddle AgedTreatment OutcomeRegistriesTime Factors

Stichwörter der Autor:innen

Impellacardiogenic shockintra‐aortic balloon pumpleft ventricular unloadingvenoarterial extracorporeal membrane oxygenation

Autor:innen und Institutionen

  • Department of Cardiology Nagoya University Graduate School of Medicine Nagoya Japan.
  • Department of Cardiology JA Aichi Koseiren Kainan Hospital Yatomi Japan.
  • Department of Advanced Medicine Nagoya University Hospital Nagoya Japan.
  • Department of Clinical Research Education Nagoya University Graduate School of Medicine Nagoya Japan.
  • Department of Cardiovascular Medicine Kitasato University School of Medicine Sagamihara Japan.
  • Department of Cardiology Kindai University Faculty of Medicine Sakai Japan.

ORCID-Profile: Toru Kondo, Shingo Kazama, Takeru Nabeta, Yuki Ikeda, Koichiro Matsumura, Koshiro Kanaoka, Toshiyuki Nagai, Takeo Fujino, Ryota Morimoto, Toyoaki Murohara

Zitieren

APA

Ito, R., Kondo, T., Kazama, S., Araki, T., Imaizumi, T., Nabeta, T., Ikeda, Y., Matsuzoe, H., Matsumura, K., Kanaoka, K., Nagai, T., Fujino, T., Morimoto, R., & Murohara, T. (2026). Left Ventricular Unloading With Impella Versus Intra‐Aortic Balloon Pump in Cardiogenic Shock Requiring Venoarterial Extracorporeal Membrane Oxygenation. Journal of the American Heart Association. https://doi.org/10.1161/jaha.125.047993

Vancouver

Ito R, Kondo T, Kazama S, Araki T, Imaizumi T, Nabeta T, et al. Left Ventricular Unloading With Impella Versus Intra‐Aortic Balloon Pump in Cardiogenic Shock Requiring Venoarterial Extracorporeal Membrane Oxygenation. Journal of the American Heart Association. 2026. doi:10.1161/jaha.125.047993

BibTeX
@article{Ito2026,
  author = {Ito, Ryota and Kondo, Toru and Kazama, Shingo and Araki, Takashi and Imaizumi, Takahiro and Nabeta, Takeru and Ikeda, Yuki and Matsuzoe, Hiroki and Matsumura, Koichiro and Kanaoka, Koshiro and Nagai, Toshiyuki and Fujino, Takeo and Morimoto, Ryota and Murohara, Toyoaki},
  title = {Left Ventricular Unloading With Impella Versus Intra‐Aortic Balloon Pump in Cardiogenic Shock Requiring Venoarterial Extracorporeal Membrane Oxygenation},
  journal = {Journal of the American Heart Association},
  year = {2026},
  doi = {10.1161/jaha.125.047993}
}
Kostenlos starten →