Effectiveness of an Impella Versus Intra‐Aortic Balloon Pump in Patients Who Received Extracorporeal Membrane Oxygenation
Journal of the American Heart Association · 04.02.2025 · 14 (3)
DOI: 10.1161/jaha.124.037652 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of the American Heart Association, erschienen am 04.02.2025. Verfasst von Yuji Nishimoto und 12 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology Osaka General Medical Center Osaka Japan. Hauptthemen laut MEDLINE: Intra-Aortic Balloon Pumping, Extracorporeal Membrane Oxygenation, Heart-Assist Devices, Shock, Cardiogenic. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
It is unclear whether an intra‐aortic balloon pump (IABP) or percutaneous ventricular assist device (Impella) in combination with extracorporeal membrane oxygenation (ECMO) is better.
Methods
Using the Japanese Diagnosis Procedure Combination database from September 2016 to March 2022, we identified inpatients who received an Impella or IABP in combination with ECMO (ECPella or ECMO+IABP group, respectively). The primary outcome was in‐hospital mortality, and the secondary outcomes included the length of hospital stay, length of ECMO, total hospitalization cost, complications, and durable mechanical circulatory support implantations. Propensity score matching was performed to compare the outcomes between the groups.
Results
Of 14 319 eligible patients, 590 (4.1%) received ECPella and 13 729 (96%) received ECMO+IABP. The mean age of patients was 65 years, 77% were men, and 57% had acute coronary syndrome. After propensity score matching, the patient characteristics were well balanced between the groups. The 14‐day mortality rate was lower in the ECPella group than in the ECMO+IABP group (28.0% versus 36.8%; risk difference, −8.2% [95% CI, −13.8 to −2.7]), whereas there was no significant difference in in‐hospital mortality between the groups (58.3% versus 56.6%; risk difference, 2.4% [95% CI, −3.5 to 8.2]). The ECPella group had a higher total hospitalization cost, increased renal replacement therapy during hospitalization, and more durable mechanical circulatory support implantations than the ECMO+IABP group.
Conclusions
This nationwide inpatient database study showed no significant difference in in‐hospital mortality between the groups, but ECPella was associated with a higher total hospitalization cost, increased renal replacement therapy during hospitalization, and more durable mechanical circulatory support implantations than ECMO+IABP.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Cardiology Osaka General Medical Center Osaka Japan.
- Department of Clinical Epidemiology and Health Economics, School of Public Health The University of Tokyo Japan.
- Division of Cardiovascular Intensive Care Nippon Medical School Tokyo Japan.
- Department of Emergency and Critical Care Medicine Nippon Medical School Tokyo Japan.
- Emergency and Critical Care Center Tokyo Metropolitan Hiroo Hospital Tokyo Japan.
- Department of Real-world Evidence, Graduate School of Medicine The University of Tokyo Japan.
ORCID-Profile: Yuji Nishimoto, Hiroyuki Ohbe, Toru Takiguchi, Mikio Nakajima, Toshiaki Isogai, Hiroki Matsui, Yukihito Sato, Tetsuya Watanabe, Takahisa Yamada, Masatake Fukunami, Hideo Yasunaga
Zitieren
APA
Nishimoto, Y., Ohbe, H., Nakata, J., Takiguchi, T., Nakajima, M., Sasabuchi, Y., Isogai, T., Matsui, H., Sato, Y., Watanabe, T., Yamada, T., Fukunami, M., & Yasunaga, H. (2025). Effectiveness of an Impella Versus Intra‐Aortic Balloon Pump in Patients Who Received Extracorporeal Membrane Oxygenation. Journal of the American Heart Association, 14(3). https://doi.org/10.1161/jaha.124.037652
Vancouver
Nishimoto Y, Ohbe H, Nakata J, Takiguchi T, Nakajima M, Sasabuchi Y, et al. Effectiveness of an Impella Versus Intra‐Aortic Balloon Pump in Patients Who Received Extracorporeal Membrane Oxygenation. Journal of the American Heart Association. 2025;14(3). doi:10.1161/jaha.124.037652
BibTeX
@article{Nishimoto2025,
author = {Nishimoto, Yuji and Ohbe, Hiroyuki and Nakata, Jun and Takiguchi, Toru and Nakajima, Mikio and Sasabuchi, Yusuke and Isogai, Toshiaki and Matsui, Hiroki and Sato, Yukihito and Watanabe, Tetsuya and Yamada, Takahisa and Fukunami, Masatake and Yasunaga, Hideo},
title = {Effectiveness of an Impella Versus Intra‐Aortic Balloon Pump in Patients Who Received Extracorporeal Membrane Oxygenation},
journal = {Journal of the American Heart Association},
year = {2025},
volume = {14},
number = {3},
doi = {10.1161/jaha.124.037652}
}
EUVIMED