EUVIMEDEUVIMED entdecken
Crossref

Caudal fluoroscopic guidance for the insertion of transvenous pacing leads

Matthew B Morton iD, Jeremy William iD, Peter M Kistler iD, Sandeep Prabhu iD, Hariharan Sugumar, Olivier Van Den Brink, Hitesh Patel, Justin Mariani, Aleksandr Voskoboinik

Journal of Cardiovascular Electrophysiology · 2024

DOI: 10.1111/jce.16183 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2024. Verfasst von Matthew B Morton und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Alfred Hospital, Melbourne, Victoria, Australia. Hauptthemen laut MEDLINE: Pacemaker, Artificial, Pneumothorax, Defibrillators, Implantable. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Pneumothorax is a well‐recognized complication of cardiac implantable electronic device (CIED) insertion. While AP fluoroscopy alone is the most commonly imaging technique for subclavian or axillary access, caudal fluoroscopy (angle 40°) is routinely used at our institution. The caudal view provides additional separation of the first rib and clavicle and may reduce the risk of pneumothorax. We assessed outcomes at our institution of AP and caudal fluoroscopic guided pacing lead insertion.

Methods

Retrospective cohort study of consecutive patients undergoing transvenous lead insertion for pacemakers, defibrillators, and cardiac resynchronization therapy devices between 2011 and 2023. Both de novo and lead replacement/upgrade procedures were included. Data were extracted from operative, radiology, and discharge reports. All patients underwent postprocedure chest radiography.

Results

Three thousand two hundred fifty‐two patients underwent insertion of pacing leads between February 2011 and March 2023. Mean age was 71.1 years (range 16–102) and 66.7% were male. Most ( n = 2536; 78.0%) procedures used caudal guidance to obtain venous access, while 716 (22.0%) procedures used AP guidance alone. Pneumothoraxes occurred in five (0.2%) patients in the caudal group and five (0.7%) patients in the AP group ( p = .03). Subclavian contrast venography was performed less frequently in the caudal group (26.2% vs. 42.7%, p < .01).

Conclusion

Caudal fluoroscopy for axillary/subclavian access is associated with a lower rate of pneumothorax and contrast venography compared with an AP approach.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pacemaker, ArtificialPneumothoraxDefibrillators, ImplantableHumansMaleAdolescentYoung AdultAdultMiddle AgedAgedAged, 80 and overFemaleAxillary VeinRetrospective StudiesFluoroscopy

Stichwörter der Autor:innen

cardiac implantable electronic device insertioncaudal fluoroscopypneumothoraxsubclavian vein puncture

Autor:innen und Institutionen

  • Department of Cardiology, Alfred Hospital, Melbourne, Victoria, Australia.

ORCID-Profile: Matthew B Morton, Jeremy William, Peter M Kistler, Sandeep Prabhu

Zitieren

APA

Morton, M. B., William, J., Kistler, P. M., Prabhu, S., Sugumar, H., Brink, O. V. D., Patel, H., Mariani, J., & Voskoboinik, A. (2024). Caudal fluoroscopic guidance for the insertion of transvenous pacing leads. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16183

Vancouver

Morton MB, William J, Kistler PM, Prabhu S, Sugumar H, Brink OVD, et al. Caudal fluoroscopic guidance for the insertion of transvenous pacing leads. Journal of Cardiovascular Electrophysiology. 2024. doi:10.1111/jce.16183

BibTeX
@article{Morton2024,
  author = {Morton, Matthew B and William, Jeremy and Kistler, Peter M and Prabhu, Sandeep and Sugumar, Hariharan and Brink, Olivier Van Den and Patel, Hitesh and Mariani, Justin and Voskoboinik, Aleksandr},
  title = {Caudal fluoroscopic guidance for the insertion of transvenous pacing leads},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2024},
  doi = {10.1111/jce.16183}
}
Kostenlos starten →