Multicenter Experience With a Novel Real‐Time 3‐Dimensional Intracardiac Echocardiography Catheter to Guide Interventional Cardiac Procedures
Journal of the American Heart Association · 2025
DOI: 10.1161/jaha.124.037019 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Journal of the American Heart Association, 2025. Verfasst von Mohamad Adnan Alkhouli und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine Mayo Clinic Rochester MN USA. Hauptthemen laut MEDLINE: Echocardiography, Three-Dimensional, Ultrasonography, Interventional, Cardiac Catheterization, Cardiac Catheters. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Recent technologies enable real‐time 3‐dimensional intracardiac echocardiography (ICE) with the advantages of 2‐dimensional ICE and imaging capabilities of transesophageal echocardiography. The purpose of this study is to evaluate the real‐world, multicenter safety and performance of a novel 3‐dimensional ICE system in a variety of cardiac interventions used in standard clinical practice.
Methods
This prospective, multicenter, observational, single‐arm study enrolled patients who were scheduled for an invasive cardiac procedure involving guidance with ICE and followed until discharge or ≤48 hours postprocedure. Intracardiac imaging was performed with the 3‐dimensional ICE catheter, VeriSight Pro (Philips Inc.). Fluoroscopy was used in all cases and transesophageal echocardiography was used in some cases. The primary safety end point was device‐related adverse events. The primary efficacy end point included technical success, imaging success, and clinical success.
Results
Between October 2021 and November 2022, 155 patients were enrolled and screened. Percutaneous interventions performed included atrial septal defect/patent foramen ovale closures, left atrial appendage occlusion, catheter ablations, and valve procedures. No adverse events were related to the device or procedure. The technical, imaging, and clinical success rates were 98.7% (95% CI, 95.4%–99.8%), 96.1% (95% CI, 91.8%–98.6%), 94.8% (95% CI, 91.8%–98.6%), respectively. Overall, the VeriSight Pro ICE image quality was assessed to be “acceptable” or greater in relation to reference image modality among 96.2% (149 of 155) of procedures.
Conclusions
VeriSight ICE imaging is safe and effective in the guidance of a wide variety of percutaneous cardiovascular procedures and has provided successful and high‐quality imaging of cardiac structures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiovascular Medicine Mayo Clinic Rochester MN USA.
- University of Colorado Hospital Aurora CO USA.
- Philips Image Guided Therapy Corporation Colorado Springs CO USA.
- Texas Cardiac Arrhythmia Institute, St. David's Medical Center Austin TX USA.
- Massachusetts General Hospital Boston MA USA.
- Center for Heart Rhythm Disorders Northwestern University, Feinberg School of Medicine Chicago IL USA.
ORCID-Profile: Mohamad Adnan Alkhouli, John D Carroll, Aken A Desai, Yu-Rong Gao, Andrea Natale, Ignacio Inglessis-Azuaje, Bradley P Knight
Zitieren
APA
Alkhouli, M. A., Carroll, J. D., Desai, A. A., Gao, Y. R., Xiong, T., Natale, A., Inglessis-Azuaje, I., & Knight, B. P. (2025). Multicenter Experience With a Novel Real‐Time 3‐Dimensional Intracardiac Echocardiography Catheter to Guide Interventional Cardiac Procedures. Journal of the American Heart Association. https://doi.org/10.1161/jaha.124.037019
Vancouver
Alkhouli MA, Carroll JD, Desai AA, Gao YR, Xiong T, Natale A, et al. Multicenter Experience With a Novel Real‐Time 3‐Dimensional Intracardiac Echocardiography Catheter to Guide Interventional Cardiac Procedures. Journal of the American Heart Association. 2025. doi:10.1161/jaha.124.037019
BibTeX
@article{Alkhouli2025,
author = {Alkhouli, Mohamad Adnan and Carroll, John D and Desai, Aken A and Gao, Yu-Rong and Xiong, Tomnema and Natale, Andrea and Inglessis-Azuaje, Ignacio and Knight, Bradley P},
title = {Multicenter Experience With a Novel Real‐Time 3‐Dimensional Intracardiac Echocardiography Catheter to Guide Interventional Cardiac Procedures},
journal = {Journal of the American Heart Association},
year = {2025},
doi = {10.1161/jaha.124.037019}
}
EUVIMED