EUVIMEDEUVIMED entdecken
Open Access

Quantifying Induced Nystagmus Using a Smartphone Eye Tracking Application (EyePhone)

Pouya B Bastani iD, Hector Rieiro iD, Shervin Badihian, Jorge Otero-Millan iD, Nathan Farrell, Max Parker, David Newman-Toker iD, Yuxin Zhu, Ali Saber Tehrani iD

Journal of the American Heart Association · 2024

DOI: 10.1161/jaha.123.030927 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the American Heart Association, 2024. Verfasst von Pouya B Bastani und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology Johns Hopkins University School of Medicine Baltimore MD USA. Hauptthemen laut MEDLINE: Nystagmus, Pathologic, Stroke. Die Arbeit wurde bisher 29-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

There are ≈5 million annual dizziness visits to US emergency departments, of which vestibular strokes account for over 250 000. The head impulse, nystagmus, and test of skew eye examination can accurately distinguish vestibular strokes from peripheral dizziness. However, the eye‐movement signs are subtle, and lack of familiarity and difficulty with recognition of abnormal eye movements are significant barriers to widespread emergency department use. To break this barrier, we sought to assess the accuracy of EyePhone, our smartphone eye‐tracking application, for quantifying nystagmus. Methods and Results We prospectively enrolled healthy volunteers and recorded the velocity of induced nystagmus using a smartphone eye‐tracking application (EyePhone) and then compared the results with video oculography (VOG). Following a calibration protocol, the participants viewed optokinetic stimuli with incremental velocities (2–12 degrees/s) in 4 directions. We extracted slow phase velocities from EyePhone data in each direction and compared them with the corresponding slow phase velocities obtained by the VOG. Furthermore, we calculated the area under the receiver operating characteristic curve for nystagmus detection by EyePhone. We enrolled 10 volunteers (90% men) with an average age of 30.2±6 years. EyePhone‐recorded slow phase velocities highly correlated with the VOG recordings (r=0.98 for horizontal and r=0.94 for vertical). The calibration significantly increased the slope of linear regression for horizontal and vertical slow phase velocities. Evaluating the EyePhone's performance using VOG data with a 2 degrees/s threshold showed an area under the receiver operating characteristic curve of 0.87 for horizontal and vertical nystagmus detection.

Conclusions

We demonstrated that EyePhone could accurately detect and quantify optokinetic nystagmus, similar to the VOG goggles.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Nystagmus, PathologicStrokeMaleHumansYoung AdultAdultFemaleEye-Tracking TechnologyDizzinessSmartphoneEye Movements

Stichwörter der Autor:innen

HINTSeye movementshealth technologynystagmusvestibular strokes

Autor:innen und Institutionen

  • Department of Neurology Johns Hopkins University School of Medicine Baltimore MD USA.
  • Armstrong Institute Center for Diagnostic Excellence Baltimore MD USA.
  • Neurological Institute, Cleveland Clinic Cleveland OH USA.
  • Herbert Wertheim School of Optometry and Vision Science University of California Berkeley CA USA.
  • Department of Neurology, NYU Langone Health New York NY USA.
  • Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health Baltimore MD USA.

ORCID-Profile: Pouya B Bastani, Hector Rieiro, Jorge Otero-Millan, David Newman-Toker, Ali Saber Tehrani

Zitieren

APA

Bastani, P. B., Rieiro, H., Badihian, S., Otero-Millan, J., Farrell, N., Parker, M., Newman-Toker, D., Zhu, Y., & Saber Tehrani, A. (2024). Quantifying Induced Nystagmus Using a Smartphone Eye Tracking Application (EyePhone). Journal of the American Heart Association. https://doi.org/10.1161/jaha.123.030927

Vancouver

Bastani PB, Rieiro H, Badihian S, Otero-Millan J, Farrell N, Parker M, et al. Quantifying Induced Nystagmus Using a Smartphone Eye Tracking Application (EyePhone). Journal of the American Heart Association. 2024. doi:10.1161/jaha.123.030927

BibTeX
@article{Bastani2024,
  author = {Bastani, Pouya B and Rieiro, Hector and Badihian, Shervin and Otero-Millan, Jorge and Farrell, Nathan and Parker, Max and Newman-Toker, David and Zhu, Yuxin and Saber Tehrani, Ali},
  title = {Quantifying Induced Nystagmus Using a Smartphone Eye Tracking Application (EyePhone)},
  journal = {Journal of the American Heart Association},
  year = {2024},
  doi = {10.1161/jaha.123.030927}
}
Kostenlos starten →