EUVIMEDEUVIMED entdecken
Open Access

Diagnostic Accuracy of Office Blood Pressure Measurement and Home Blood Pressure Monitoring for Hypertension Screening Among Adults: Results From the IDH Study

Hiroyuki Mizuno iD, Eunhee Choi iD, Kazuomi Kario iD, Paul Muntner iD, Chloe L Fang, Justin Liu, Dona N Sangapalaarachchi iD, Michael Lam iD, Yuichiro Yano iD, Joseph E Schwartz iD, Daichi Shimbo iD

Journal of the American Heart Association · 2023

DOI: 10.1161/jaha.123.030150 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the American Heart Association, 2023. Verfasst von Hiroyuki Mizuno und 10 weiteren Autor:innen. Beteiligte Einrichtung: The Columbia Hypertension Center and Lab Columbia University Irving Medical Center New York NY. Hauptthemen laut MEDLINE: Blood Pressure Monitoring, Ambulatory, Hypertension. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Using high awake blood pressure (BP; ≥130/80 mm Hg) on ambulatory BP monitoring (ABPM) as a reference, the purpose of this study was to determine the accuracy of high office BP (≥130/80 mm Hg) at an initial visit and high confirmatory office BP (≥130/80 mm Hg), and separately, high home BP (≥130/80 mm Hg) among participants with high office BP (≥130/80 mm Hg) at an initial office visit. Methods and Results The accuracy of office BP measurements using the oscillometric method for detecting high BP on ABPM was determined among 379 participants with complete office BP and ABPM data in the IDH (Improving the Detection of Hypertension) study. For detecting high BP on ABPM, the accuracy of high confirmatory office BP using the oscillometric method and, separately, high home BP was also determined among the subgroup of 122 participants with high office BP at an initial visit and complete home BP monitoring data. High office BP had moderate sensitivity (0.61 [95% CI, 0.53–0.68]) and high specificity (0.85 [95% CI, 0.80–0.90]) for high awake BP. High confirmatory office BP and high home BP had moderate sensitivity (0.69 [95% CI, 0.59–0.79] and 0.79 [95% CI, 0.71–0.87], respectively) and low and moderate specificity (0.44 [95% CI, 0.27–0.61] and 0.72 [95% CI, 0.56–0.88], respectively).

Conclusions

Many individuals with high BP on ABPM do not have high office BP. Confirmatory office BP and home blood pressure monitoring also had limited ability to identify individuals with high BP on ABPM.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood Pressure Monitoring, AmbulatoryHypertensionAdultHumansBlood PressureBlood Pressure DeterminationOffice Visits

Stichwörter der Autor:innen

ambulatory blood pressure monitoringhome blood pressure monitoringhypertension screeningoffice blood pressure measurement

Autor:innen und Institutionen

  • The Columbia Hypertension Center and Lab Columbia University Irving Medical Center New York NY.
  • Division of Cardiovascular Medicine Jichi Medical University School of Medicine Tochigi Japan.
  • Department of Epidemiology, School of Public Health University of Alabama at Birmingham Birmingham AL.
  • Noncommunicable Disease (NCD) Epidemiology Research Center Shiga University of Medical Science Shiga Japan.
  • Department of Family Medicine and Community Health Duke University Durham NC.
  • Center for Behavioral Cardiovascular Health Columbia University Irving Medical Center New York NY.

ORCID-Profile: Hiroyuki Mizuno, Eunhee Choi, Kazuomi Kario, Paul Muntner, Dona N Sangapalaarachchi, Michael Lam, Yuichiro Yano, Joseph E Schwartz, Daichi Shimbo

Förderung

  • NHLBI NIH HHS

Zitieren

APA

Mizuno, H., Choi, E., Kario, K., Muntner, P., Fang, C. L., Liu, J., Sangapalaarachchi, D. N., Lam, M., Yano, Y., Schwartz, J. E., & Shimbo, D. (2023). Diagnostic Accuracy of Office Blood Pressure Measurement and Home Blood Pressure Monitoring for Hypertension Screening Among Adults: Results From the IDH Study. Journal of the American Heart Association. https://doi.org/10.1161/jaha.123.030150

Vancouver

Mizuno H, Choi E, Kario K, Muntner P, Fang CL, Liu J, et al. Diagnostic Accuracy of Office Blood Pressure Measurement and Home Blood Pressure Monitoring for Hypertension Screening Among Adults: Results From the IDH Study. Journal of the American Heart Association. 2023. doi:10.1161/jaha.123.030150

BibTeX
@article{Mizuno2023,
  author = {Mizuno, Hiroyuki and Choi, Eunhee and Kario, Kazuomi and Muntner, Paul and Fang, Chloe L and Liu, Justin and Sangapalaarachchi, Dona N and Lam, Michael and Yano, Yuichiro and Schwartz, Joseph E and Shimbo, Daichi},
  title = {Diagnostic Accuracy of Office Blood Pressure Measurement and Home Blood Pressure Monitoring for Hypertension Screening Among Adults: Results From the IDH Study},
  journal = {Journal of the American Heart Association},
  year = {2023},
  doi = {10.1161/jaha.123.030150}
}