EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access · CC BY-NC 4.0

The HOPE Asia Network consensus on blood pressure measurements corresponding to office measurements: Automated office, home, and ambulatory blood pressures

Jinho Shin iD, Ji-Guang Wang iD, Yook-Chin Chia, Kazuomi Kario iD, Chen-Huan Chen iD, Hao-Min Cheng, Takeshi Fujiwara iD, Satoshi Hoshide iD, Minh Van Huynh iD, Yan Li iD, Michiaki Nagai iD, Jennifer Nailes iD und 13 weitere

The Journal of Clinical Hypertension · 2024-12 · 26 (12) · 1351-1361

DOI: 10.1111/jch.14729 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift The Journal of Clinical Hypertension, online erschienen am 25.10.2023. Verfasst von Jinho Shin und 24 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Department of Internal Medicine, Hanyang University College of Medicine, Seoul, South Korea. Hauptthemen laut MEDLINE: Blood Pressure Monitoring, Ambulatory, Hypertension, White Coat Hypertension, Blood Pressure. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

For adopting recently introduced hypertension phenotypes categorized using office and out of office blood pressure (BP) for the diagnosis of hypertension and antihypertension drug therapy, it is mandatory to define the corresponding out of office BP with the specific target BP recommended by the major guidelines. Such conditions include white‐coat hypertension (WCH), masked hypertension (MH), white‐coat uncontrolled hypertension (WUCH), and masked uncontrolled hypertension (MUCH). Here, the authors review the relevant literature and discuss the related issue to facilitate the use of corresponding BPs for proper diagnosis of WCH, MH, WUCH, and MUCH in the setting of standard target BP as well as intensive target BP. The methodology of deriving the corresponding BP has evolved from statistical methods such as standard deviation, percentile value, and regression to an outcome‐based approach using pooled international cohort study data and comparative analysis in randomized clinical trials for target BPs such as the SPRINT and STEP studies. Corresponding BPs to 140/90 and 130/80 mm Hg in office BP is important for safe and strict achievement of intensive BP targets. The corresponding home, daytime, and 24‐h BPs to 130/80 mm Hg in office BP are 130/80, 130/80, and 125/75 mm Hg, respectively. However, researchers have found some discrepancies among the home corresponding BPs. As tentative criterion for de‐escalation of antihypertensive therapy as shown in European guidelines was 120 mm Hg in office BP, corresponding home, daytime, and 24‐h systolic BPs to 120 mm Hg in office systolic BP are 120, 120, and 115 mm Hg, respectively.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood Pressure Monitoring, AmbulatoryHypertensionWhite Coat HypertensionBlood PressureBlood Pressure DeterminationHumansMasked HypertensionOffice VisitsAntihypertensive AgentsAsia

Stichwörter der Autor:innen

ambulatory blood pressure/home blood pressure monitorantihypertensive therapycorresponding blood pressureshypertension guidelinesmasked uncontrolled hypertensionwhite‐coat hypertension

Substanzen

Antihypertensive Agents

Autor:innen und Institutionen

  • Division of Cardiology, Department of Internal Medicine, Hanyang University College of Medicine, Seoul, South Korea.
  • Department of Cardiovascular Medicine, The Shanghai Institute of Hypertension, Shanghai Key Laboratory of Hypertension, National Research Centre for Translational Medicine, Ruijin Hospital, Shanghai Jiaotong University…
  • Department of Medical Sciences, School of Healthcare and Medical Sciences, Sunway University, Bandar Sunway, Selangor Darul Ehsan, Malaysia.
  • Department of Primary Care Medicine, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia.
  • Division of Cardiovascular Medicine, Department of Medicine, Jichi Medical University School of Medicine, Tochigi, Japan.
  • Department of Medicine, National Yang-Ming Chiao Tung University College of Medicine, Taipei, Taiwan.

ORCID-Profile: Jinho Shin, Ji-Guang Wang, Kazuomi Kario, Chen-Huan Chen, Takeshi Fujiwara, Satoshi Hoshide, Minh Van Huynh, Yan Li, Michiaki Nagai, Jennifer Nailes, Sungha Park, Saulat Siddique, Guru Prasad Sogunuru, Jam Chin Tay, Boon Wee Teo, Naoko Tomitani, Kelvin Tsoi, Yuda Turana, Narsingh Verma, Tzung-Dau Wang

Zitieren

APA

Shin, J., Wang, J. G., Chia, Y. C., Kario, K., Chen, C. H., Cheng, H. M., Fujiwara, T., Hoshide, S., Huynh, M. V., Li, Y., Nagai, M., Nailes, J., Park, S., Siddique, S., Sison, J., Soenarta, A. A., Sogunuru, G. P., Tay, J. C., Teo, B. W., …, & Zhang, Y. (2024). The HOPE Asia Network consensus on blood pressure measurements corresponding to office measurements: Automated office, home, and ambulatory blood pressures. The Journal of Clinical Hypertension, 26(12), 1351-1361. https://doi.org/10.1111/jch.14729

Vancouver

Shin J, Wang JG, Chia YC, Kario K, Chen CH, Cheng HM, et al. The HOPE Asia Network consensus on blood pressure measurements corresponding to office measurements: Automated office, home, and ambulatory blood pressures. The Journal of Clinical Hypertension. 2024;26(12):1351-1361. doi:10.1111/jch.14729

BibTeX
@article{Shin2024,
  author = {Shin, Jinho and Wang, Ji-Guang and Chia, Yook-Chin and Kario, Kazuomi and Chen, Chen-Huan and Cheng, Hao-Min and Fujiwara, Takeshi and Hoshide, Satoshi and Huynh, Minh Van and Li, Yan and Nagai, Michiaki and Nailes, Jennifer and Park, Sungha and Siddique, Saulat and Sison, Jorge and Soenarta, Arieska Ann and Sogunuru, Guru Prasad and Tay, Jam Chin and Teo, Boon Wee and Tomitani, Naoko and Tsoi, Kelvin and Turana, Yuda and Verma, Narsingh and Wang, Tzung-Dau and Zhang, Yuqing},
  title = {The HOPE Asia Network consensus on blood pressure measurements corresponding to office measurements: Automated office, home, and ambulatory blood pressures},
  journal = {The Journal of Clinical Hypertension},
  year = {2024},
  volume = {26},
  number = {12},
  pages = {1351--1361},
  doi = {10.1111/jch.14729}
}
Kostenlos starten →