Rising and Falling High‐Sensitivity Cardiac Troponin in Diagnostic Algorithms for Patients With Suspected Myocardial Infarction
Journal of the American Heart Association · 2023
DOI: 10.1161/jaha.122.027166 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the American Heart Association, 2023. Verfasst von Paul M Haller und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology University Heart and Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf Hamburg Germany. Hauptthemen laut MEDLINE: Myocardial Infarction. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
High‐sensitivity cardiac troponin (hs‐cTn)‐based diagnostic algorithms are recommended for the management of patients with suspected myocardial infarction (MI) without ST elevation. Although mirroring different phases of myocardial injury, falling and rising troponin patterns (FPs and RPs, respectively) are equally considered by most algorithms. We aimed to compare the performance of diagnostic protocols for RPs and FPs, separately. Methods and Results We pooled 2 prospective cohorts of patients with suspected MI and stratified patients to stable, FP, and RP during serial sampling separately for hs‐cTnI and hs‐cTnT and applied the European Society of Cardiology 0/1‐ and 0/3‐hour algorithms comparing the positive predictive values to rule in MI. Overall, 3523 patients were included in the hs‐cTnI study population. The positive predictive value for patients with an FP was significantly reduced compared with patients with an RP (0/1‐hour: FP, 53.3% [95% CI, 45.0–61.4] versus RP, 76.9 [95% CI, 71.6–81.7]; 0/3‐hour: FP, 56.9% [95% CI, 42.2–70.7] versus RP, 78.1% [95% CI, 74.0–81.8]). The proportion of patients in the observe zone was larger in the FP using 0/1‐hour (31.3% versus 55.8%) and 0/3‐hour (14.6% versus 38.6%) algorithms. Alternative cutoffs did not improve algorithm performances. Compared with stable hs‐cTn, the risk for death or MI was highest in those with an FP (adjusted hazard ratio [HR], hs‐cTnI 2.3 [95% CI, 1.7–3.2]; RP adjusted HR, hs‐cTnI 1.8 [95% CI, 1.4–2.4]). Findings were similar for hs‐cTnT tested in 3647 patients overall.
Conclusions
The positive predictive value to rule in MI by the European Society of Cardiology 0/1‐ and 0/3‐hour algorithms is significantly lower in patients with FP than RP. These are at highest risk for incident death or MI. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifiers: NCT02355457, NCT03227159.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Cardiology University Heart and Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf Hamburg Germany.
- German Center for Cardiovascular Research (DZHK), Partner Site Hamburg/Kiel/Lübeck Hamburg Germany.
- University Center of Cardiovascular Science University Heart and Vascular Center Hamburg, University Medical Center Hamburg-Eppendorf Hamburg Germany.
- Department of Internal Medicine I, Cardiology Justus-Liebig-University Gießen Gießen Germany.
- Department of Cardiology University Heart Center Freiburg Bad Krotzingen Bad Krotzingen Germany.
- Department of Epidemiology and Preventive Medicine, School of Public Health and Preventive Medicine Monash University Melbourne Australia.
ORCID-Profile: Paul M Haller, Nils A Sörensen, Tau S Hartikainen, Alina Goßling, Betül Toprak, Raphael Twerenbold, Solaf Korschid, Jakob Schmidt, Stefan Blankenberg, Dirk Westermann, Johannes T Neumann
Zitieren
APA
Haller, P. M., Sörensen, N. A., Hartikainen, T. S., Goßling, A., Lehmacher, J., Toprak, B., Twerenbold, R., Richter, J., Banko, T., Korschid, S., Schmidt, J., Keller, T., Zeller, T., Blankenberg, S., Westermann, D., & Neumann, J. T. (2023). Rising and Falling High‐Sensitivity Cardiac Troponin in Diagnostic Algorithms for Patients With Suspected Myocardial Infarction. Journal of the American Heart Association. https://doi.org/10.1161/jaha.122.027166
Vancouver
Haller PM, Sörensen NA, Hartikainen TS, Goßling A, Lehmacher J, Toprak B, et al. Rising and Falling High‐Sensitivity Cardiac Troponin in Diagnostic Algorithms for Patients With Suspected Myocardial Infarction. Journal of the American Heart Association. 2023. doi:10.1161/jaha.122.027166
BibTeX
@article{Haller2023,
author = {Haller, Paul M and Sörensen, Nils A and Hartikainen, Tau S and Goßling, Alina and Lehmacher, Jonas and Toprak, Betül and Twerenbold, Raphael and Richter, Janine and Banko, Thorben and Korschid, Solaf and Schmidt, Jakob and Keller, Till and Zeller, Tanja and Blankenberg, Stefan and Westermann, Dirk and Neumann, Johannes T},
title = {Rising and Falling High‐Sensitivity Cardiac Troponin in Diagnostic Algorithms for Patients With Suspected Myocardial Infarction},
journal = {Journal of the American Heart Association},
year = {2023},
doi = {10.1161/jaha.122.027166}
}