Abstract 36: Patient-Owned Home Blood Pressure Devices Commonly Disagree With Automated Clinic Reference Measurements
Hypertension · 2026-10 · 83 (Suppl_1)
DOI: 10.1161/hyp.83.suppl_1.36 ↗Kurz gefasst
Fachartikel in der Zeitschrift Hypertension, 2026-10. Verfasst von Arnav Mehra und 3 weiteren Autor:innen.
Abstract (Originalsprache)
Introduction
Hypertension affects more than one billion adults worldwide, and blood pressure (BP) measurement errors can lead to misclassification of hypertension status and treatment. Home blood pressure (BP) monitoring is recommended for hypertension diagnosis and management, but its clinical value depends on patient-owned devices producing readings that agree with reference measurements.
Objective
To assess the frequency of clinically meaningful disagreement between patient-owned home BP devices and automated clinic reference measurements.
Methods
In a specialty hypertension clinic, a patient-owned BP device validation protocol during rooming. Following five minutes of seated rest, two measures were taken with our annually calibrated Omron HEM-970XL (A), and two with the patient-owned device (B) using an A-B-B-A sequence. The average with each device was calculated and compared. Clinically meaningful disagreement was defined as an absolute difference >10 mmHg based on prior clinical device-comparison literature. In addition, all patients had a standard automated office BP measured using the Omron HEM-970XL. Exploratory analyses tested for associations between patient characteristics and BP device disagreement.
Results
Participants were 266 consecutive patients who brough their home device to an office visit between January 2018 and April 2026. Their mean age was 64.1±15.1 years, 153 (57.5%) were female, mean body mass index was 30.4±7.5 kg/m2, and 238 (89.5%) used upper-arm devices. The mean BP was 141.2 ± 21.5 mmHg systolic and 79.8 ± 13.9 mmHg diastolic based on our reference measurements. Clinically meaningful disagreement was present in 85 (32.0%) of patient-owned devices for systolic BP, 66 (24.8%) for diastolic BP, and 118 (44.4%) for either systolic or diastolic BP (Figure 1). Mean absolute disagreement was 9.1 mmHg for systolic BP and 7.6 mmHg for diastolic BP. In exploratory analyses, higher body mass index (BMI) was associated with greater absolute and clinically meaningful disagreement (p
Zitieren
APA
Mehra, A., Abramovitz, B. W., Ray, E. C., & Muldoon, M. F. (2026). Abstract 36: Patient-Owned Home Blood Pressure Devices Commonly Disagree With Automated Clinic Reference Measurements. Hypertension, 83(Suppl_1). https://doi.org/10.1161/hyp.83.suppl_1.36
Vancouver
Mehra A, Abramovitz BW, Ray EC, Muldoon MF. Abstract 36: Patient-Owned Home Blood Pressure Devices Commonly Disagree With Automated Clinic Reference Measurements. Hypertension. 2026;83(Suppl_1). doi:10.1161/hyp.83.suppl_1.36
BibTeX
@article{Mehra2026,
author = {Mehra, Arnav and Abramovitz, Blaise W and Ray, Evan C and Muldoon, Matthew F},
title = {Abstract 36: Patient-Owned Home Blood Pressure Devices Commonly Disagree With Automated Clinic Reference Measurements},
journal = {Hypertension},
year = {2026},
volume = {83},
number = {Suppl_1},
doi = {10.1161/hyp.83.suppl_1.36}
}
EUVIMED