EUVIMEDEUVIMED entdecken
Crossref

Optical Coherence Tomography–Guided or Intravascular Ultrasound–Guided PCI for In-Stent Restenosis Lesions: Insights From the OCTIVUS Trial

Kyeong-Won Seo, Do-Yoon Kang, Jung-Min Ahn, Ji Sung Lee, Ju Hyeon Kim, Han-Su Park, Soo Yeon An, Seong-Bong Wee, Seunghan Lee, Seung-Ho Hur, Yun-Kyeong Cho, Cheol Hyun Lee und 10 weitere

Circulation: Cardiovascular Interventions · 23.11.2026

DOI: 10.1161/circinterventions.126.017174 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Circulation: Cardiovascular Interventions, online erschienen am 23.11.2026. Verfasst von Kyeong-Won Seo und 21 weiteren Autor:innen. Die Arbeit nennt 28 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: In-stent restenosis (ISR) remains a significant challenge despite advances in percutaneous coronary intervention (PCI) technology. Although intravascular imaging improves procedural optimization, direct comparative data between optical coherence tomography (OCT) and intravascular ultrasound (IVUS) for ISR treatment remain limited. METHODS: This study was a prespecified analysis of ISR lesions from the OCTIVUS trial (Optical Coherence Tomography–Guided Versus Intravascular Ultrasound–Guided Percutaneous Coronary Intervention). The primary outcome was target-vessel failure, defined as a composite of cardiac death, target-vessel-related myocardial infarction, or ischemia-driven target-vessel revascularization. Crude and adjusted analyses using inverse-probability-of-treatment weighting and overlap propensity score weighting were performed. RESULTS: Among the 2008 patients enrolled in the OCTIVUS trial, 164 (8.2%) underwent intravascular imaging–guided PCI for ISR lesions; 86 (52.4%) underwent OCT-guided PCI and 78 (47.6%) underwent IVUS-guided PCI. At a median follow-up of 1.8 years, the incidence of target-vessel failure was significantly lower in the OCT-guided group than in the IVUS-guided group (10.5% versus 29.5%; hazard ratio, 0.34 [95% CI, 0.16–0.74]; P =0.007). The lower incidence of target-vessel failure with OCT was consistent in adjusted analyses using inverse-probability-of-treatment weighting (hazard ratio, 0.31 [95% CI, 0.14–0.69]; P =0.004) and overlap propensity score weighting (hazard ratio, 0.31 [95% CI, 0.14–0.70]; P =0.005). CONCLUSIONS: For the treatment of ISR lesions, OCT-guided PCI was associated with a lower risk of target-vessel failure than IVUS-guided PCI. However, given the exploratory nature of this analysis, these findings should not be considered clinically directive and warrant further investigation. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03394079.

Zitieren

APA

Seo, K., Kang, D., Ahn, J., Lee, J. S., Kim, J. H., Park, H., An, S. Y., Wee, S., Lee, S., Hur, S., Cho, Y., Lee, C. H., Hong, S. J., Lim, S., Kim, S., Won, H., Hong, Y. J., Yoon, Y., Yoon, Y. W., …, & Park, D. (2026). Optical Coherence Tomography–Guided or Intravascular Ultrasound–Guided PCI for In-Stent Restenosis Lesions: Insights From the OCTIVUS Trial. Circulation: Cardiovascular Interventions. https://doi.org/10.1161/circinterventions.126.017174

Vancouver

Seo K, Kang D, Ahn J, Lee JS, Kim JH, Park H, et al. Optical Coherence Tomography–Guided or Intravascular Ultrasound–Guided PCI for In-Stent Restenosis Lesions: Insights From the OCTIVUS Trial. Circulation: Cardiovascular Interventions. 2026. doi:10.1161/circinterventions.126.017174

BibTeX
@article{Seo2026,
  author = {Seo, Kyeong-Won and Kang, Do-Yoon and Ahn, Jung-Min and Lee, Ji Sung and Kim, Ju Hyeon and Park, Han-Su and An, Soo Yeon and Wee, Seong-Bong and Lee, Seunghan and Hur, Seung-Ho and Cho, Yun-Kyeong and Lee, Cheol Hyun and Hong, Soon Jun and Lim, Subin and Kim, Sang-Wook and Won, Hoyoun and Hong, Young Joon and Yoon, Yong‑Hoon and Yoon, Young Won and Bae, Jang-Ho and Park, Seung-Jung and Park, Duk-Woo},
  title = {Optical Coherence Tomography–Guided or Intravascular Ultrasound–Guided PCI for In-Stent Restenosis Lesions: Insights From the OCTIVUS Trial},
  journal = {Circulation: Cardiovascular Interventions},
  year = {2026},
  doi = {10.1161/circinterventions.126.017174}
}
Kostenlos starten →