EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Transcatheter Mitral Valve Replacement Using Annular Reduction by Cinching With TEER in the Commissure (ARCTIC)

Gregory J Condos iD, David Elison, Logan L Vincent, Rafael Harari, Cristina Sanina iD, Srdjan Jelacic iD, Richard Sheu iD, Christine J Chung iD, Gabriel S Aldea, G Burkhard Mackensen iD, James M McCabe iD

Circulation: Cardiovascular Interventions · 2024

DOI: 10.1161/circinterventions.124.014224 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Circulation: Cardiovascular Interventions, 2024. Verfasst von Gregory J Condos und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology (G.J.C., D.E., C.S., C.J.C., J.M.M.), University of Washington School of Medicine, Seattle. Hauptthemen laut MEDLINE: Mitral Valve, Heart Valve Prosthesis, Heart Valve Prosthesis Implantation, Cardiac Catheterization. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Mitral annular calcification with valve dysfunction remains a challenging syndrome. Operative risk is high, and available transcatheter therapies are limited. METHODS: This study describes our initial experience with a novel procedure to address large mitral annuli when no surgical or trial-based transcatheter mitral valve replacement device is available. The rationale was to shorten the intercommissural distance using commissural mitral transcatheter edge-to-edge repair (TEER) followed by valve-in-mitral annular calcification transcatheter mitral valve replacement with a balloon-expandable aortic valve platform. Patients with long intercommissural distances and large mitral annulus areas were selected based on a high perceived risk of transcatheter valve embolization. Patients underwent mitral TEER with MitraClip in a commissural position, followed immediately by transseptal transcatheter mitral valve replacement with a 29 mm SAPIEN 3 valve. RESULTS: Thirteen patients were included. Median intercommissural distance and annular area were 39.1 mm and 930 mm 2 , respectively. Commissural mitral TEER was successful in all patients with no instances of single leaflet detachment. In 10 of 13 instances, an NTW device size was used. In 12 of 13 patients, valve implantation was successful, including 1 case that required a second valve for atrial positioning of the first valve. In 1 case, frank valve embolization into the left atrium occurred. Among the 12 successful cases, paravalvular leak was 1+ or less, and there were no instances of paravalvular leak adjacent to the TEER device. CONCLUSIONS: In patients with large annuli and sufficient annular calcium, a hybrid mitral TEER and valve replacement with the SAPIEN platform can be successfully used to facilitate transcatheter mitral valve replacement.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Mitral ValveHeart Valve ProsthesisHeart Valve Prosthesis ImplantationCardiac CatheterizationProsthesis DesignCalcinosisHumansFemaleMaleAgedTreatment OutcomeAged, 80 and overMitral Valve InsufficiencyMitral Valve AnnuloplastyRecovery of FunctionTime FactorsMiddle Aged

Stichwörter der Autor:innen

heart valve diseaseshumansmitral valvemitral valve insufficiencymitral valve stenosis

Autor:innen und Institutionen

  • Department of Cardiology (G.J.C., D.E., C.S., C.J.C., J.M.M.), University of Washington School of Medicine, Seattle.
  • Providence Heart and Vascular Institute, Providence St Vincent Medical Center, Portland, OR (L.L.V.).
  • Department of Cardiology, New York University Langone School of Medicine (R.H.).
  • Department of Anesthesiology and Pain Medicine (S.J., R.S., G.B.M.), University of Washington School of Medicine, Seattle.
  • Department of Cardiothoracic Surgery (G.S.A.), University of Washington School of Medicine, Seattle.

ORCID-Profile: Gregory J Condos, Cristina Sanina, Srdjan Jelacic, Richard Sheu, Christine J Chung, G Burkhard Mackensen, James M McCabe

Zitieren

APA

Condos, G. J., Elison, D., Vincent, L. L., Harari, R., Sanina, C., Jelacic, S., Sheu, R., Chung, C. J., Aldea, G. S., Mackensen, G. B., & McCabe, J. M. (2024). Transcatheter Mitral Valve Replacement Using Annular Reduction by Cinching With TEER in the Commissure (ARCTIC). Circulation: Cardiovascular Interventions. https://doi.org/10.1161/circinterventions.124.014224

Vancouver

Condos GJ, Elison D, Vincent LL, Harari R, Sanina C, Jelacic S, et al. Transcatheter Mitral Valve Replacement Using Annular Reduction by Cinching With TEER in the Commissure (ARCTIC). Circulation: Cardiovascular Interventions. 2024. doi:10.1161/circinterventions.124.014224

BibTeX
@article{Condos2024,
  author = {Condos, Gregory J and Elison, David and Vincent, Logan L and Harari, Rafael and Sanina, Cristina and Jelacic, Srdjan and Sheu, Richard and Chung, Christine J and Aldea, Gabriel S and Mackensen, G Burkhard and McCabe, James M},
  title = {Transcatheter Mitral Valve Replacement Using Annular Reduction by Cinching With TEER in the Commissure (ARCTIC)},
  journal = {Circulation: Cardiovascular Interventions},
  year = {2024},
  doi = {10.1161/circinterventions.124.014224}
}
Kostenlos starten →