EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Real Time Hemodynamic Monitoring During M‐TEER Using Electrical Cardiometry

Andreas Goldschmied iD, Manuel Sigle, Ioannis Toskas, Monika Zdanyte, Mareike Bladt, Meinrad Gawaz, Tobias Geisler

Catheterization and Cardiovascular Interventions · 2025

DOI: 10.1002/ccd.31527 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Andreas Goldschmied und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, University Hospital Tübingen, Tübingen, Germany. Hauptthemen laut MEDLINE: Mitral Valve Insufficiency, Cardiac Catheterization, Mitral Valve, Hemodynamic Monitoring. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The ICON® electrical cardiometry system was provided by OSYPKA MEDICAL..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Mitral regurgitation is a common valvular dysfunction causing patient morbidity and mortality. Mitral transcatheter edge‐to‐edge repair (M‐TEER) allows grasping of valvular leaflets and approximation via a small implant, thus reducing mitral regurgitation (MR). The implant allows staged leaflet capture and leaflet optimization before it is finally released. Real time hemodynamic monitoring could facilitate procedural success and improve patient outcomes.

Methods

Fourteen patients scheduled for elective M‐TEER were included in this study. Right heart catheterization (RHC) and determination of cardiac stroke volume (SV) using the established Fick method, pulmonary capillary wedge pressure (PCWP), PCWP v‐wave, left atrial (LA) pressure and LA v‐wave were carried out pre and postprocedurally. Concomitantly, real time SV was measured via electrical cardiometry and acquired data were compared.

Results

A significant increase in cardiac stroke volume measured via RHC was observed after successful M‐TEER. Even though pre‐ and postprocedural RHC and electrical cardiometry measurements correlated significantly, electrical cardiometry was not able to reproduce the absolute increase in SV seen on RHC measurements. Furthermore, a decrease in PCWP mean pressure, PCWP v‐wave, LA mean pressure and LA v‐wave, were observed.

Conclusion

Cardiac SV increases after successful M‐TEER as measured via RHC but electrical cardiometry was not able to reproduce these changes in a real time, beat‐to‐beat measurement.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Mitral Valve InsufficiencyCardiac CatheterizationMitral ValveHemodynamic MonitoringHemodynamicsHeart Valve Prosthesis ImplantationEchocardiography, TransesophagealHumansMaleFemaleAgedTime FactorsPredictive Value of TestsTreatment OutcomeMiddle AgedStroke VolumeAged, 80 and overHeart Valve Prosthesis

Stichwörter der Autor:innen

M‐TEERelectrical cardiometryhemodynamicsmitral regurgitationright heart catheter

Autor:innen und Institutionen

  • Department of Cardiology, University Hospital Tübingen, Tübingen, Germany.

ORCID-Profile: Andreas Goldschmied

Förderung

  • The ICON® electrical cardiometry system was provided by OSYPKA MEDICAL.

Zitieren

APA

Goldschmied, A., Sigle, M., Toskas, I., Zdanyte, M., Bladt, M., Gawaz, M., & Geisler, T. (2025). Real Time Hemodynamic Monitoring During M‐TEER Using Electrical Cardiometry. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31527

Vancouver

Goldschmied A, Sigle M, Toskas I, Zdanyte M, Bladt M, Gawaz M, et al. Real Time Hemodynamic Monitoring During M‐TEER Using Electrical Cardiometry. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.31527

BibTeX
@article{Goldschmied2025,
  author = {Goldschmied, Andreas and Sigle, Manuel and Toskas, Ioannis and Zdanyte, Monika and Bladt, Mareike and Gawaz, Meinrad and Geisler, Tobias},
  title = {Real Time Hemodynamic Monitoring During M‐TEER Using Electrical Cardiometry},
  journal = {Catheterization and Cardiovascular Interventions},
  year = {2025},
  doi = {10.1002/ccd.31527}
}
Kostenlos starten →