Real Time Hemodynamic Monitoring During M‐TEER Using Electrical Cardiometry
Catheterization and Cardiovascular Interventions · 2025
DOI: 10.1002/ccd.31527 ↗Kurz gefasst
Fachartikel in der Zeitschrift Catheterization and Cardiovascular Interventions, 2025. Verfasst von Andreas Goldschmied und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, University Hospital Tübingen, Tübingen, Germany. Hauptthemen laut MEDLINE: Mitral Valve Insufficiency, Cardiac Catheterization, Mitral Valve, Hemodynamic Monitoring. Die Arbeit nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The ICON® electrical cardiometry system was provided by OSYPKA MEDICAL..
Abstract (Originalsprache)
Background
Mitral regurgitation is a common valvular dysfunction causing patient morbidity and mortality. Mitral transcatheter edge‐to‐edge repair (M‐TEER) allows grasping of valvular leaflets and approximation via a small implant, thus reducing mitral regurgitation (MR). The implant allows staged leaflet capture and leaflet optimization before it is finally released. Real time hemodynamic monitoring could facilitate procedural success and improve patient outcomes.
Methods
Fourteen patients scheduled for elective M‐TEER were included in this study. Right heart catheterization (RHC) and determination of cardiac stroke volume (SV) using the established Fick method, pulmonary capillary wedge pressure (PCWP), PCWP v‐wave, left atrial (LA) pressure and LA v‐wave were carried out pre and postprocedurally. Concomitantly, real time SV was measured via electrical cardiometry and acquired data were compared.
Results
A significant increase in cardiac stroke volume measured via RHC was observed after successful M‐TEER. Even though pre‐ and postprocedural RHC and electrical cardiometry measurements correlated significantly, electrical cardiometry was not able to reproduce the absolute increase in SV seen on RHC measurements. Furthermore, a decrease in PCWP mean pressure, PCWP v‐wave, LA mean pressure and LA v‐wave, were observed.
Conclusion
Cardiac SV increases after successful M‐TEER as measured via RHC but electrical cardiometry was not able to reproduce these changes in a real time, beat‐to‐beat measurement.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, University Hospital Tübingen, Tübingen, Germany.
ORCID-Profile: Andreas Goldschmied
Förderung
- The ICON® electrical cardiometry system was provided by OSYPKA MEDICAL.
Zitieren
APA
Goldschmied, A., Sigle, M., Toskas, I., Zdanyte, M., Bladt, M., Gawaz, M., & Geisler, T. (2025). Real Time Hemodynamic Monitoring During M‐TEER Using Electrical Cardiometry. Catheterization and Cardiovascular Interventions. https://doi.org/10.1002/ccd.31527
Vancouver
Goldschmied A, Sigle M, Toskas I, Zdanyte M, Bladt M, Gawaz M, et al. Real Time Hemodynamic Monitoring During M‐TEER Using Electrical Cardiometry. Catheterization and Cardiovascular Interventions. 2025. doi:10.1002/ccd.31527
BibTeX
@article{Goldschmied2025,
author = {Goldschmied, Andreas and Sigle, Manuel and Toskas, Ioannis and Zdanyte, Monika and Bladt, Mareike and Gawaz, Meinrad and Geisler, Tobias},
title = {Real Time Hemodynamic Monitoring During M‐TEER Using Electrical Cardiometry},
journal = {Catheterization and Cardiovascular Interventions},
year = {2025},
doi = {10.1002/ccd.31527}
}
EUVIMED