Transcatheter Pulmonary Valve Replacement With the Harmony Valve in Patients Who Do Not Meet Recommended Oversizing Criteria on the Screening Perimeter Plot

Doff B McElhinney, Matthew J Gillespie, Jamil A Aboulhosn, Allison K Cabalka iD, Brian H Morray iD, David T Balzer, Athar M Qureshi iD, Arvind K Hoskoppal iD, Bryan H Goldstein iD

Circulation: Cardiovascular Interventions · 2024-05 · 17 (5)

DOI: 10.1161/circinterventions.123.013889 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Circulation: Cardiovascular Interventions, 2024-05. Verfasst von Doff B McElhinney und 8 weiteren Autor:innen. Beteiligte Einrichtung: Departments of Cardiothoracic Surgery and Pediatrics (Cardiology), Stanford University School of Medicine, Palo Alto, CA (D.B.M.E.). Hauptthemen laut MEDLINE: Pulmonary Valve, Heart Valve Prosthesis, Heart Valve Prosthesis Implantation, Cardiac Catheterization. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 10 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Anatomic selection for Harmony valve implant is determined with the aid of a screening report and perimeter plot (PP) that depicts the perimeter-derived radius along the right ventricular outflow tract (RVOT) and projects device oversizing. The PP provides an estimation of suitability for implant, but its sensitivity as a screening method is unknown. This study was performed to describe anatomic features and outcomes in patients who underwent Harmony TPV25 implant despite a PP that predicted inadequate oversizing. METHODS: We reviewed RVOT anatomic features and measurements in patients who underwent transcatheter pulmonary valve replacement with the Harmony TPV25 device despite a PP that predicted inadequate oversizing. RESULTS: This study included 22 patients. There were no unsuccessful implants or adverse valve-related events. Anatomic features varied, but all patients fit into 1 of 3 anatomic types characterized by differences in RVOT dimensions. Type 1 patients (n=9) had a long RVOT with a choke point and a wide main pulmonary artery. Type 2 patients (n=6) had a short RVOT that was pyramidal in shape, with no choke point, and extensive main pulmonary artery lengthening/expansion during systole. Type 3 patients (n=7) had a short, bulbous main pulmonary artery with a choke point and an open pulmonary artery bifurcation. CONCLUSIONS: Transcatheter pulmonary valve replacement with the Harmony valve is feasible in some patients whose PP fit analysis predicts inadequate oversizing. All cases in this series fit into 1 of 3 anatomic patterns, which are not identified in the screening report. Implanters must review cases individually to assess the feasibility of the implant.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pulmonary ValveHeart Valve ProsthesisHeart Valve Prosthesis ImplantationCardiac CatheterizationProsthesis DesignHumansTreatment OutcomeMaleFemaleAdolescentYoung AdultChildAdultRetrospective StudiesPredictive Value of TestsPulmonary Valve InsufficiencyPatient SelectionClinical Decision-MakingRecovery of FunctionHemodynamics

Stichwörter der Autor:innen

implantpatientpulmonary arterypulmonary valvetetralogy of Fallot

Autor:innen und Institutionen

  • Departments of Cardiothoracic Surgery and Pediatrics (Cardiology), Stanford University School of Medicine, Palo Alto, CA (D.B.M.E.).
  • Division of Pediatric Cardiology, University of Pennsylvania School of Medicine and The Children's Hospital of Philadelphia (M.J.G.).
  • Division of Cardiology, UCLA Medical Center, Los Angeles, CA (J.A.A.).
  • Divisions of Pediatric Cardiology and Structural Heart Diseases, Mayo Clinic, Rochester, MN (A.K.C.).
  • Seattle Children's Hospital, University of Washington (B.H.M.).
  • Division of Pediatric Cardiology, Washington University School of Medicine, St. Louis, MO (D.T.B.).

ORCID-Profile: Allison K Cabalka, Brian H Morray, Athar M Qureshi, Arvind K Hoskoppal, Bryan H Goldstein

Zitieren

APA

McElhinney, D. B., Gillespie, M. J., Aboulhosn, J. A., Cabalka, A. K., Morray, B. H., Balzer, D. T., Qureshi, A. M., Hoskoppal, A. K., & Goldstein, B. H. (2024). Transcatheter Pulmonary Valve Replacement With the Harmony Valve in Patients Who Do Not Meet Recommended Oversizing Criteria on the Screening Perimeter Plot. Circulation: Cardiovascular Interventions, 17(5). https://doi.org/10.1161/circinterventions.123.013889

Vancouver

McElhinney DB, Gillespie MJ, Aboulhosn JA, Cabalka AK, Morray BH, Balzer DT, et al. Transcatheter Pulmonary Valve Replacement With the Harmony Valve in Patients Who Do Not Meet Recommended Oversizing Criteria on the Screening Perimeter Plot. Circulation: Cardiovascular Interventions. 2024;17(5). doi:10.1161/circinterventions.123.013889

BibTeX
@article{McElhinney2024,
  author = {McElhinney, Doff B and Gillespie, Matthew J and Aboulhosn, Jamil A and Cabalka, Allison K and Morray, Brian H and Balzer, David T and Qureshi, Athar M and Hoskoppal, Arvind K and Goldstein, Bryan H},
  title = {Transcatheter Pulmonary Valve Replacement With the Harmony Valve in Patients Who Do Not Meet Recommended Oversizing Criteria on the Screening Perimeter Plot},
  journal = {Circulation: Cardiovascular Interventions},
  year = {2024},
  volume = {17},
  number = {5},
  doi = {10.1161/circinterventions.123.013889}
}
Kostenlos starten →