Lesion Durability of the Second Generation Pentaspline Pulsed Field Ablation Catheter NAVIGATE-PF Phase 2 Results
Circulation: Arrhythmia and Electrophysiology · 2026
DOI: 10.1161/circep.125.014477 ↗Kurz gefasst
Klinische Studie (Phase II) in der Zeitschrift Circulation: Arrhythmia and Electrophysiology, 2026. Verfasst von Vivek Y Reddy und 10 weiteren Autor:innen. Beteiligte Einrichtung: Homolka Hospital, Prague, Czech Republic (V.Y.R., J.P., M.F., P.N.). Hauptthemen laut MEDLINE: Atrial Fibrillation, Catheter Ablation, Pulmonary Veins, Cardiac Catheters. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
BACKGROUND: Remapping studies have evaluated chronic lesion durability of the first-generation pentaspline pulsed field ablation (PFA) catheter that did not have integrated electroanatomical mapping. By invasive remapping, this first-in-human study evaluated the durability of lesions facilitated by the integration of the navigation-enabled pentaspline PFA catheter and mapping system in patients with atrial fibrillation. METHODS: The NAVIGATE-PF Phase 2 trial evaluated the second-generation, mapping-integrated pentaspline PFA catheter. Lesion durability was assessed by invasive remapping 60 days post index procedure. RESULTS: After index ablation in 20 patients with the pentaspline PFA catheter, remaps were performed 60 days later in 17 patients, demonstrating a high rate of lesion durability in the pulmonary veins (95%) and posterior wall (86%). CONCLUSIONS: By facilitating real-time visualization of catheter positioning and acute lesion estimation through tags, the second-generation map-and-ablate pentaspline PFA catheter and integrated mapping system may enhance procedural success. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT06175234.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Homolka Hospital, Prague, Czech Republic (V.Y.R., J.P., M.F., P.N.).
- Helmsley Electrophysiology Center, Mount Sinai Fuster Heart Hospital, NY (V.Y.R.).
- Boston Scientific Corporation, St. Paul, MN (S.C., C.M., B.O., E.M., T.O., S.R.G., B.E.K.).
ORCID-Profile: Vivek Y Reddy, Moritoshi Funasako, Brynn Okeson, Evripidis Mikos, Brendan E Koop, Petr Neuzil
Zitieren
APA
Reddy, V. Y., Petru, J., Funasako, M., Canepa, S., Metzdorff, C., Okeson, B., Mikos, E., Oesterlein, T., Gutbrod, S. R., Koop, B. E., & Neuzil, P. (2026). Lesion Durability of the Second Generation Pentaspline Pulsed Field Ablation Catheter NAVIGATE-PF Phase 2 Results. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.125.014477
Vancouver
Reddy VY, Petru J, Funasako M, Canepa S, Metzdorff C, Okeson B, et al. Lesion Durability of the Second Generation Pentaspline Pulsed Field Ablation Catheter NAVIGATE-PF Phase 2 Results. Circulation: Arrhythmia and Electrophysiology. 2026. doi:10.1161/circep.125.014477
BibTeX
@article{Reddy2026,
author = {Reddy, Vivek Y and Petru, Jan and Funasako, Moritoshi and Canepa, Silvia and Metzdorff, Camille and Okeson, Brynn and Mikos, Evripidis and Oesterlein, Tobias and Gutbrod, Sarah R and Koop, Brendan E and Neuzil, Petr},
title = {Lesion Durability of the Second Generation Pentaspline Pulsed Field Ablation Catheter NAVIGATE-PF Phase 2 Results},
journal = {Circulation: Arrhythmia and Electrophysiology},
year = {2026},
doi = {10.1161/circep.125.014477}
}
EUVIMED