Ultra-Low Cryoablation for Scar-Related VT Ablation: Results From the US Early Feasibility Study
Circulation: Arrhythmia and Electrophysiology · 2026
DOI: 10.1161/circep.125.014095 ↗Kurz gefasst
Klinische Studie in der Zeitschrift Circulation: Arrhythmia and Electrophysiology, 2026. Verfasst von J Peter Weiss und 8 weiteren Autor:innen. Beteiligte Einrichtung: University Medical Center Phoenix, The University of Arizona College of Medicine, Phoenix, AZ (J.P.W., R.T.). Hauptthemen laut MEDLINE: Catheter Ablation, Cicatrix, Cryosurgery, Tachycardia, Ventricular. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: A limitation of ablation for scar-related ventricular tachycardia (VT) is insufficient lesion depth to address nonendocardial substrate. Ultra-low temperature cryoablation (ULTC) at −196°C has been shown to create transmural lesions in preclinical models. Early human studies in Europe have shown safety and efficacy. METHODS: An EFS (Early Feasibility Study) was designed in collaboration with the Food and Drug Administration as a prospective, nonrandomized evaluation of the acute safety and effectiveness of ULTC ablation for scar-related VT. RESULTS: Twenty patients (age 63±14 years; 5% women; LVEF 36±13%; 45% ischemic and 55% nonischemic) underwent VT ablation with ULTC from September to December 2023 at 4 clinical sites. Ablation strategies included substrate modification during sinus rhythm, as well as activation and entrainment mapping when hemodynamics permitted. Mean ULTC lesions were 9.9±3.6, with a total freeze duration of 47±22 minutes. Noninducibility of the targeted VTs was observed in 13 of 14 patients with inducibility tested both pre- and postablation. There were no procedural strokes, tamponades, or deaths. One suspected cardiac perforation without tamponade was conservatively managed. One patient was excluded from the follow-up efficacy analysis due to RF use, and another lacked postacute follow-up due to death from heart failure 1 month post-procedure. Among surviving per-protocol patients, 23.7±4.3 weeks of freedom from VT and implantable cardioverter defibrillator shock were 61.1% (11/18) and 83.3% (15/18), respectively. CONCLUSIONS: In a US EFS, ULTC therapy was safe and effective for the treatment of scar-related VT. The EFS design, in collaboration with the Food and Drug Administration, represents an important initiative to accelerate the evaluation of new medical technologies in the United States. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT05675865.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- University Medical Center Phoenix, The University of Arizona College of Medicine, Phoenix, AZ (J.P.W., R.T.).
- Icahn School of Medicine, New York, NY (V.Y.R.).
- Vanderbilt University Medical Center, Nashville, TN (H.T., T.D.R., W.G.S.).
- University of California, San Francisco, CA (E.P.G.).
- Adagio Medical, Inc., Laguna Hills, CA (N.J., I.G.).
ORCID-Profile: J Peter Weiss, Vivek Y Reddy, Harikrishna Tandri, Travis D Richardson, Edward P Gerstenfeld, William G Stevenson, Ilya Grigorov, Roderick Tung
Zitieren
APA
Weiss, J. P., Reddy, V. Y., Tandri, H., Richardson, T. D., Gerstenfeld, E. P., Stevenson, W. G., Jubran, N., Grigorov, I., & Tung, R. (2026). Ultra-Low Cryoablation for Scar-Related VT Ablation: Results From the US Early Feasibility Study. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.125.014095
Vancouver
Weiss JP, Reddy VY, Tandri H, Richardson TD, Gerstenfeld EP, Stevenson WG, et al. Ultra-Low Cryoablation for Scar-Related VT Ablation: Results From the US Early Feasibility Study. Circulation: Arrhythmia and Electrophysiology. 2026. doi:10.1161/circep.125.014095
BibTeX
@article{Weiss2026,
author = {Weiss, J Peter and Reddy, Vivek Y and Tandri, Harikrishna and Richardson, Travis D and Gerstenfeld, Edward P and Stevenson, William G and Jubran, Nabil and Grigorov, Ilya and Tung, Roderick},
title = {Ultra-Low Cryoablation for Scar-Related VT Ablation: Results From the US Early Feasibility Study},
journal = {Circulation: Arrhythmia and Electrophysiology},
year = {2026},
doi = {10.1161/circep.125.014095}
}
EUVIMED