EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieVergleichsstudie

Comparison of Procedural Outcomes of Lumenless Fixed-Helix Versus Stylet-Driven Extendable-Helix Lead Systems in Left Bundle Branch Pacing: COMPARE LBBP

Jenish P Shroff iD, Anugrah Nair iD, Deep Chandh Raja iD, Sreevilasam P Abhilash, Simon Fiorese, Jonathan P Ariyaratnam, Walter P Abhayaratna iD, Prashanthan Sanders iD, Pugazhendhi Vijayaraman iD, Rajeev K Pathak iD

Circulation: Arrhythmia and Electrophysiology · 2024-12 · 17 (12)

DOI: 10.1161/circep.124.013385 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Circulation: Arrhythmia and Electrophysiology, 2024-12. Verfasst von Jenish P Shroff und 9 weiteren Autor:innen. Beteiligte Einrichtung: The School of Medicine and Psychology, Australian National University, Australian Capital Territory (J.P.S., A.N., D.C.R., W.P.A., R.K.P.). Hauptthemen laut MEDLINE: Bundle of His. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Left bundle branch pacing (LBBP) has emerged as a safe and effective alternative to right ventricular pacing. Traditionally, LBBP is performed with lumenless lead (LLL); however, the use of stylet-driven lead (SDL) is on rise. We aimed to assess acute success and procedural outcomes of SDL versus LLL for LBBP. METHODS: One hundred consecutive patients with bradyarrhythmia, indication of cardiac resynchronization therapy, or ablate and pace strategy were randomized in a 1:1 fashion to the SDL and LLL arms. Tendril STS lead with a CPS Locator 3D catheter and SelectSecure 3830 lead with a C315HIS catheter were used in the SDL and LLL arms, respectively. LBBP was confirmed by standard criteria with measurements done on Labsystem Pro. RESULTS: Patients in the LLL arm were significantly younger (71.9±11 versus 76.4±8.9 years; P =0.02); all other baseline characteristics were not significantly different. Acute success in LBBP was similar with SDL versus LLL (90% versus 92%; P =0.7). In patients with successful LBBP, screw attempts were not significantly different between the groups (2.3±1.7 in SDL versus 1.9±1.3 in LLL; P =0.2). Implant duration (11±9.6 versus 9.9±7.1 minutes; P =0.4), mean fluoroscopy dose (65.3±82.7 versus 53.5±50.5 mGy; P =0.5), and fluoroscopy time (7.8±4.8 versus 7.4±4 minutes; P =0.7) were also not different in the SDL versus the LLL arm, respectively. Incidence of lead failure ( P =0.6), microdislodgement ( P =1), and macrodislodgement ( P =0.6) were not significantly different. Pacing threshold was comparable at implant and on follow-up at 1, 3, and 6 months. CONCLUSIONS: LBBP was feasible with both lead systems with similar success rate and low capture threshold. No significant difference was observed in procedure duration or fluoroscopy use. No major complications were recorded with either lead. REGISTRATION: URL: https://www.anzctr.org.au ; Unique identifier: ACTRN12624000304538.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bundle of HisHumansMaleFemaleAgedTreatment OutcomeBradycardiaTime FactorsMiddle AgedEquipment DesignBundle-Branch BlockCardiac Pacing, ArtificialAged, 80 and overHeart RateCardiac Resynchronization Therapy DevicesProspective Studies

Stichwörter der Autor:innen

cardiac resynchronization therapyhumansincidenceleadrandomized controlled trial

Autor:innen und Institutionen

  • The School of Medicine and Psychology, Australian National University, Australian Capital Territory (J.P.S., A.N., D.C.R., W.P.A., R.K.P.).
  • Canberra Heart Rhythm Centre, Australian Capital Territory (J.P.S., A.N., S.P.A., S.F., R.K.P.).
  • Centre for Heart Rhythm Disorders, University of Adelaide and Royal Adelaide Hospital, Australia (J.P.A., P.S.).
  • Geisinger Heart Institute, Geisinger Commonwealth School of Medicine, Wilkes-Barre, PA (P.V.).

ORCID-Profile: Jenish P Shroff, Anugrah Nair, Deep Chandh Raja, Walter P Abhayaratna, Prashanthan Sanders, Pugazhendhi Vijayaraman, Rajeev K Pathak

Zitieren

APA

Shroff, J. P., Nair, A., Raja, D. C., Abhilash, S. P., Fiorese, S., Ariyaratnam, J. P., Abhayaratna, W. P., Sanders, P., Vijayaraman, P., & Pathak, R. K. (2024). Comparison of Procedural Outcomes of Lumenless Fixed-Helix Versus Stylet-Driven Extendable-Helix Lead Systems in Left Bundle Branch Pacing: COMPARE LBBP. Circulation: Arrhythmia and Electrophysiology, 17(12). https://doi.org/10.1161/circep.124.013385

Vancouver

Shroff JP, Nair A, Raja DC, Abhilash SP, Fiorese S, Ariyaratnam JP, et al. Comparison of Procedural Outcomes of Lumenless Fixed-Helix Versus Stylet-Driven Extendable-Helix Lead Systems in Left Bundle Branch Pacing: COMPARE LBBP. Circulation: Arrhythmia and Electrophysiology. 2024;17(12). doi:10.1161/circep.124.013385

BibTeX
@article{Shroff2024,
  author = {Shroff, Jenish P and Nair, Anugrah and Raja, Deep Chandh and Abhilash, Sreevilasam P and Fiorese, Simon and Ariyaratnam, Jonathan P and Abhayaratna, Walter P and Sanders, Prashanthan and Vijayaraman, Pugazhendhi and Pathak, Rajeev K},
  title = {Comparison of Procedural Outcomes of Lumenless Fixed-Helix Versus Stylet-Driven Extendable-Helix Lead Systems in Left Bundle Branch Pacing: COMPARE LBBP},
  journal = {Circulation: Arrhythmia and Electrophysiology},
  year = {2024},
  volume = {17},
  number = {12},
  doi = {10.1161/circep.124.013385}
}
Kostenlos starten →