Sane Approach to Optimizing the Workload in Remote Monitoring of Cardiovascular Implantable Electronic Devices
Circulation: Arrhythmia and Electrophysiology · 2025
DOI: 10.1161/circep.124.013078 ↗Kurz gefasst
Fachartikel in der Zeitschrift Circulation: Arrhythmia and Electrophysiology, 2025. Verfasst von Markus Sane und 8 weiteren Autor:innen. Beteiligte Einrichtung: Helsinki University Hospital Heart and Lung Center, Finland (M.S., T.J., A.M., E.P., C.A., E.T., L.K., P.R., J.K.). Hauptthemen laut MEDLINE: Defibrillators, Implantable, Workload, Pacemaker, Artificial, Remote Sensing Technology. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
BACKGROUND: Remote monitoring offers an effective and safe method for monitoring patients with cardiovascular implantable electronic devices. The downside of remote monitoring is the overflow of the data. Since many of the remote monitoring transmissions are nonactionable, optimizing alert transmissions could partly overcome this problem. METHODS: We collected data on the number and the causes of all alert-, scheduled-, and patient-initiated transmissions as well as actions initiated by these transmissions in 2023. According to our strategy, all clinically nonrelevant alerts were turned off. The trend of alert transmissions and the proportion of actionable scheduled transmissions are presented. The patient safety was monitored by analyzing the premortem alerts and changes to alert settings in deceased patients, as well as the rate of actionable scheduled or patient-initiated transmissions during follow-up. RESULTS: During the study period 8182 transmissions were generated from 3732 cardiovascular implantable electronic devices. Of these, 2306 (28%) were alert transmissions, of which 57% (n=1290) were considered clinically nonrelevant. The rate of alerts decreased by 44% from January to December (0.07 versus 0.04 per device per month, P =0.001). Of the 3335 scheduled transmissions, 11% (364) were actionable, and the proportion of actionable scheduled transmissions remained unchanged during the follow-up period ( P =0.08). Notably, none of the deaths were linked to the adjustment of alert settings. CONCLUSIONS: Our data indicated that active evaluation of the clinical relevance of all alert transmissions and deactivation of clinically nonrelevant alerts reduce the remote monitoring workload. However, long-term follow-up is needed to ensure that patient safety is not compromised.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Helsinki University Hospital Heart and Lung Center, Finland (M.S., T.J., A.M., E.P., C.A., E.T., L.K., P.R., J.K.).
- Helsinki University, Finland (M.S., T.J., A.M., J.K.).
ORCID-Profile: Markus Sane, Toni Jäntti, Pekka Raatikainen, Jarkko Karvonen
Zitieren
APA
Sane, M., Jäntti, T., Marjamaa, A., Pennanen, E., Aura, C., Torvinen, E., Karjalainen, L., Raatikainen, P., & Karvonen, J. (2025). Sane Approach to Optimizing the Workload in Remote Monitoring of Cardiovascular Implantable Electronic Devices. Circulation: Arrhythmia and Electrophysiology. https://doi.org/10.1161/circep.124.013078
Vancouver
Sane M, Jäntti T, Marjamaa A, Pennanen E, Aura C, Torvinen E, et al. Sane Approach to Optimizing the Workload in Remote Monitoring of Cardiovascular Implantable Electronic Devices. Circulation: Arrhythmia and Electrophysiology. 2025. doi:10.1161/circep.124.013078
BibTeX
@article{Sane2025,
author = {Sane, Markus and Jäntti, Toni and Marjamaa, Annukka and Pennanen, Elina and Aura, Charlotte and Torvinen, Eeva and Karjalainen, Leena and Raatikainen, Pekka and Karvonen, Jarkko},
title = {Sane Approach to Optimizing the Workload in Remote Monitoring of Cardiovascular Implantable Electronic Devices},
journal = {Circulation: Arrhythmia and Electrophysiology},
year = {2025},
doi = {10.1161/circep.124.013078}
}
EUVIMED