EUVIMEDEUVIMED entdecken
Crossref

Current State of Cardiac Implantable Electronic Device Remote Monitoring in Pediatrics and Congenital Heart Disease: A PACES-Sponsored Quality Improvement Initiative

Bradley C Clark, Melissa Olen, Brynn Dechert, Caitlin Brateng, Beth Jarosz, Karen Smoots, Patrick Connell, Svjetlana Tisma Dupanovic, Arnold Fenrich, Allison C Hill, Martin LaPage, Douglas Mah und 8 weitere

Pediatric Cardiology · 2024

DOI: 10.1007/s00246-023-03348-x ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pediatric Cardiology, 2024. Verfasst von Bradley C Clark und 19 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Department of Pediatrics, Masonic Children's Hospital, University of Minnesota, 2450 Riverside Ave, AO-405, Minneapolis, MN, …. Hauptthemen laut MEDLINE: Heart Defects, Congenital, Pacemaker, Artificial, Defibrillators, Implantable. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 12 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cardiac implantable electronic device (CIED) remote transmissions are an integral part of longitudinal follow-up in pediatric and adult congenital heart disease (ACHD) patients. To evaluate baseline CIED remote monitoring (RM) data among pediatric and ACHD centers prior to implementation of a Pediatric and Congenital Electrophysiology Society (PACES)-sponsored quality improvement (QI) project. This is a cross-sectional study of baseline CIED RM. Centers self-reported baseline data: individual center RM compliance was defined as high if there was > 80% achievement and low if 80% of their CIED patients are enrolled in RM and only two centers reported < 50% participation. 36% reported high compliance of device transmission within 14 days of implant and 77% of centers reported high compliance of CIED patients enrolled in RM. The number of centers achieving high compliance differed by device type: 36% for pacemakers, 50% for ICDs, and 55% for Implantable Cardiac Monitors (ICM). All centers reported at least 50% adherence to recommended follow-up for PM and ICD, with 23% low compliance rate for ICMs. Based on this cross-sectional survey of pediatric and ACHD centers, compliance with CIED RM is sub-optimal. The PACES-sponsored QI initiative will provide resources and support to participating centers and repeat data will be evaluated after PDSA cycles.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Defects, CongenitalPacemaker, ArtificialDefibrillators, ImplantableChildHumansAdultCross-Sectional StudiesQuality ImprovementRemote Sensing Technology

Stichwörter der Autor:innen

ICDImplantable cardiac monitorPacemakerPediatricsQuality improvement

Autor:innen und Institutionen

  • Division of Cardiology, Department of Pediatrics, Masonic Children's Hospital, University of Minnesota, 2450 Riverside Ave, AO-405, Minneapolis, MN, 55454, USA. bradleyclarkep@gmail.com.
  • Division of Cardiology, Nicklaus Children's Hospital, Miami, FL, USA.
  • Division of Pediatric Cardiology, University of Michigan, Ann Arbor, MI, USA.
  • Division of Cardiology, Children's Hospital of Colorado, Aurora, CO, USA.
  • Division of Cardiology, Children's National Medical Center, Washington, DC, USA.
  • Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, PA, USA.

Zitieren

APA

Clark, B. C., Olen, M., Dechert, B., Brateng, C., Jarosz, B., Smoots, K., Connell, P., Dupanovic, S. T., Fenrich, A., Hill, A. C., LaPage, M., Mah, D., McCanta, A., Malloy-Walton, L., Pflaumer, A., Radbill, A., Tanel, R., Whitehill, R., Dalal, A., & Pediatric and Congenital Electrophysiology Society (PACES) (2024). Current State of Cardiac Implantable Electronic Device Remote Monitoring in Pediatrics and Congenital Heart Disease: A PACES-Sponsored Quality Improvement Initiative. Pediatric Cardiology. https://doi.org/10.1007/s00246-023-03348-x

Vancouver

Clark BC, Olen M, Dechert B, Brateng C, Jarosz B, Smoots K, et al. Current State of Cardiac Implantable Electronic Device Remote Monitoring in Pediatrics and Congenital Heart Disease: A PACES-Sponsored Quality Improvement Initiative. Pediatric Cardiology. 2024. doi:10.1007/s00246-023-03348-x

BibTeX
@article{Clark2024,
  author = {Clark, Bradley C and Olen, Melissa and Dechert, Brynn and Brateng, Caitlin and Jarosz, Beth and Smoots, Karen and Connell, Patrick and Dupanovic, Svjetlana Tisma and Fenrich, Arnold and Hill, Allison C and LaPage, Martin and Mah, Douglas and McCanta, Anthony and Malloy-Walton, Lindsey and Pflaumer, Andreas and Radbill, Andrew and Tanel, Ronn and Whitehill, Robert and Dalal, Aarti and Pediatric and Congenital Electrophysiology Society (PACES), Pediatric and Congenital Electrophysiology Society (PACES)},
  title = {Current State of Cardiac Implantable Electronic Device Remote Monitoring in Pediatrics and Congenital Heart Disease: A PACES-Sponsored Quality Improvement Initiative},
  journal = {Pediatric Cardiology},
  year = {2024},
  doi = {10.1007/s00246-023-03348-x}
}
Kostenlos starten →