Fachartikel in der Zeitschrift Artificial Organs, online erschienen am 17.03.2025. Verfasst von Carlos Alberto Valdes und 10 weiteren Autor:innen. Beteiligte Einrichtung: University of Florida College of Medicine, Gainesville, Florida, USA. Hauptthemen laut MEDLINE: Axillary Artery, Intra-Aortic Balloon Pumping. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 13 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS, NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Intra‐aortic balloon pumps (IABP) are commonly used as a bridge to heart transplant (Htx). Although IABPs were designed for transfemoral arterial placement, axillary IABPs (axIABP) allow for continued ambulation and rehabilitation. However, increased rates of device complications with axillary compared to femoral insertion suggest anatomic variations that predispose patients to device failure.

Methods

We conducted a single‐center retrospective study of patients who received axIABP as a bridge to HTx between February 2018 and July 2022. Pre‐axIABP computed tomography (CT) images were reviewed for all patients, and anatomic features of the axillary and central arteries were measured and correlated with mechanical axIABP complications.

Results

A total of 48 patients underwent successful axIABP placement with available pre‐insertion CT images, of whom 35 (72.9%) were male. Out of 48 patients, 26 (54.2%) experienced 34 complications, including axIABP rupture ( n = 10, 29%), infection ( n = 8, 23%), and thrombosis ( n = 6, 18%). CTs showed an average axillary artery diameter and depth of 6.79 and 55.6 mm, respectively. The average subclavian artery takeoff angle from the aortic arch was 95.4°.

Conclusion

Of the 10 vascular anatomic features measured, there was no association between any single measurement and axIABP complications. However, there may be other structural features not measured by routine CT, technical issues with insertion, and device factors not accounted for in this study that drive axIABP complications. Nonetheless, our findings suggest that normal variations in the measured vascular anatomy should not preclude axIABP use.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Axillary ArteryIntra-Aortic Balloon PumpingHumansMaleFemaleRetrospective StudiesMiddle AgedHeart TransplantationAgedAdultTomography, X-Ray ComputedHeart-Assist Devices

Stichwörter der Autor:innen

axillaryheart failureintra‐aortic balloon pumpmechanical circulatory support

Autor:innen und Institutionen

  • University of Florida College of Medicine, Gainesville, Florida, USA.
  • Division of Cardiovascular Medicine, Department of Medicine, University of Florida Health, Gainesville, Florida, USA.

ORCID-Profile: Carlos Alberto Valdes, Mustafa M Ahmed

Förderung

  • NHLBI NIH HHS
  • NIH HHS
  • National Institutes of Health

Zitieren

APA

Valdes, C. A., Drew, K., Sharaf, O. M., Ahmed, M. M., Parker, A. M., Vilaro, J. R., Aranda, J. M., Massoomi, M. R., Anderson, R. D., Jimenez, Y., & Al-Ani, M. A. Z. (2025). Anatomic Suitability for Axillary Intra‐Aortic Balloon Pump Circulatory Support. Artificial Organs, 49(7), 1207-1214. https://doi.org/10.1111/aor.14994

Vancouver

Valdes CA, Drew K, Sharaf OM, Ahmed MM, Parker AM, Vilaro JR, et al. Anatomic Suitability for Axillary Intra‐Aortic Balloon Pump Circulatory Support. Artificial Organs. 2025;49(7):1207-1214. doi:10.1111/aor.14994

BibTeX
@article{Valdes2025,
  author = {Valdes, Carlos Alberto and Drew, Kristin and Sharaf, Omar M and Ahmed, Mustafa M and Parker, Alex M and Vilaro, Juan R and Aranda, Juan M and Massoomi, Michael R and Anderson, R David and Jimenez, Yomary and Al-Ani, Mohammad A Z},
  title = {Anatomic Suitability for Axillary Intra‐Aortic Balloon Pump Circulatory Support},
  journal = {Artificial Organs},
  year = {2025},
  volume = {49},
  number = {7},
  pages = {1207--1214},
  doi = {10.1111/aor.14994}
}
Kostenlos starten →