EUVIMEDEUVIMED entdecken
Crossref

Abstract 4846: Self Expanding Valves and Calcification Increase Paravalvular Leak After Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve

Ermilo Echeverria, Alfredo Perez Tagle Tejeda, Juan Pastor-Cervantes

Circulation · 02.11.2026 · 154 (Suppl_1)

DOI: 10.1161/circ.154.suppl_1.4846 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Circulation, erschienen am 02.11.2026. Verfasst von Ermilo Echeverria und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Transcatheter aortic valve replacement (TAVR) has become the mainstay treatment for severe aortic stenosis across all surgical risk profiles. As indications expand to younger populations, the proportion of patients with Bicuspid Aortic Valve (BAV) undergoing TAVR is increasing. However, BAV anatomy—including elliptical annulus, calcified raphe, and extensive leaflet and left ventricular outflow tract (LVOT) calcification—poses unique procedural challenges and is associated with a higher incidence of paravalvular leak (PVL). Given its association with worse outcomes, identifying modifiable predictors of PVL in BAV is critical for optimizing TAVR performance.

Methods

A systematic review was conducted using PubMed, EBSCOhost, Cochrane Library, and Google Scholar to identify studies evaluating predictors of PVL following transcatheter aortic valve replacement in bicuspid aortic valve patients. Observational studies reporting odds ratios (ORs) for PVL were included. Extracted variables were grouped into device-related, anatomical (calcification), and procedural domains. Random-effects meta-analyses were performed using log-transformed ORs. Heterogeneity was assessed with I 2 statistics. Analyses were performed using R.

Results

Five studies including 2,500 patients were analyzed. Higher calcification burden (LVOT/annular) was consistently associated with PVL (pooled OR 2.75, 95% CI 1.75-4.33; I 2 =0.0%), while raphe calcification demonstrated a significant association with PVL (pooled OR 1.07, 95% CI 1.03-1.11; I 2 =0.0%), although data was limited. Self-expanding valves were associated with a significantly increased risk of PVL compared with balloon-expandable valves (pooled OR 2.91, 95% CI 1.13-7.46; I 2 =85.5%).Post-dilatation showed a non-significant trend toward increased PVL (pooled OR 1.57, 95% CI 0.92-2.69; I 2 =63.5%).

Conclusions

In patients with BAV undergoing TAVR, self-expanding valves and increased calcification burden are the principal determinants of PVL. These findings highlight the importance of pre-procedural anatomical assessment and device selection to mitigate PVL risk. Further refinement of procedural strategies and patient selection may improve outcomes in this complex population.

Zitieren

APA

Echeverria, E., Tejeda, A. P. T., & Pastor-Cervantes, J. (2026). Abstract 4846: Self Expanding Valves and Calcification Increase Paravalvular Leak After Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve. Circulation, 154(Suppl_1). https://doi.org/10.1161/circ.154.suppl_1.4846

Vancouver

Echeverria E, Tejeda APT, Pastor-Cervantes J. Abstract 4846: Self Expanding Valves and Calcification Increase Paravalvular Leak After Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve. Circulation. 2026;154(Suppl_1). doi:10.1161/circ.154.suppl_1.4846

BibTeX
@article{Echeverria2026,
  author = {Echeverria, Ermilo and Tejeda, Alfredo Perez Tagle and Pastor-Cervantes, Juan},
  title = {Abstract 4846: Self Expanding Valves and Calcification Increase Paravalvular Leak After Transcatheter Aortic Valve Replacement in Bicuspid Aortic Valve},
  journal = {Circulation},
  year = {2026},
  volume = {154},
  number = {Suppl_1},
  doi = {10.1161/circ.154.suppl_1.4846}
}
Kostenlos starten →